000154627 245__ $$aImage quality of list-mode proton imaging without front trackers.
000154627 260__ $$aBristol$$bIOP Publ.$$c2020
000154627 3367_ $$2DRIVER$$aarticle
000154627 3367_ $$2DataCite$$aOutput Types/Journal article
000154627 3367_ $$0PUB:(DE-HGF)16$$2PUB:(DE-HGF)$$aJournal Article$$bjournal$$mjournal$$s1600861500_5651
000154627 3367_ $$2BibTeX$$aARTICLE
000154627 3367_ $$2ORCID$$aJOURNAL_ARTICLE
000154627 3367_ $$00$$2EndNote$$aJournal Article
000154627 500__ $$a2020 Jul 9;65(13):135012#LA:E041#
000154627 520__ $$aList mode proton imaging relies on accurate reconstruction of the proton most likely path (MLP) through the patient. This typically requires two sets of position sensitive detector systems, one upstream (front) and one downstream (rear) of the patient. However, for a clinical implementation it can be preferable to omit the front trackers (single-sided proton imaging). For such a system, the MLP can be computed from information available through the beam delivery system and the remaining rear tracker set. In this work, we use Monte Carlo simulations to compare a conventional double-sided (using both front and rear detector systems) with a single-sided system (only rear detector system) by evaluating the spatial resolution of proton radiographs (pRad) and proton CT images (pCT) acquired with these set-ups. Both the pencil beam spot size, as well as the spacing between spots was also adjusted to identify the impact of these beam parameters on the image quality. Relying only on the pencil beam central position for computing the MLP resulted in severe image artifacts both in pRad and pCT. Using the recently extended-MLP formalism that incorporate pencil beam uncertainty removed these image artifacts. However, using a more focused pencil beam with this algorithm induced image artifacts when the spot spacing was the same as the beam spot size. The spatial resolution tested with a sharp edge gradient technique was reduced by 40 % for single-sided (MTF10%=3.0 lp/cm) compared to double-sided (MTF10 %=4.9 lp/cm) pRad with ideal tracking detectors. Using realistic trackers the difference decreased to 30%, with MTF10% of4.0 lp/cm for the realistic double-sided and 2.7 lp/cm for the realistic single-sided setup. When studying an anthropomorphic paediatric head phantom both single- and double-sided set-ups performed similarly where the difference between the two set-ups were less than 0.01 mm in homogeneous areas of the head. Larger discrepancies between the two set-ups were visible in high density gradients like the facial structures. A complete CT reconstruction of a Catphan® module was performed. Assuming ideal detectors, the obtained spatial resolution was 5.1 lp/cm for double-sided and 3.8 lp/cm for the single-sided setup. Double- and single-sided pRad with realistic tracker properties returned a spatial resolution of 3.8 lp/cm and 3.2 lp/cm, respectively. Future studies should investigate the development of dedicated reconstruction algorithms targeted for single-sided particle imaging.
000154627 536__ $$0G:(DE-HGF)POF3-315$$a315 - Imaging and radiooncology (POF3-315)$$cPOF3-315$$fPOF III$$x0
000154627 588__ $$aDataset connected to CrossRef, PubMed,
000154627 7001_ $$0P:(DE-He78)84cedecbe48f90adc2a1453780bdaf33$$aVolz, Lennart$$b1$$udkfz
000154627 7001_ $$00000-0003-4879-771X$$aPettersen, Helge Egil Seime Egil Seime$$b2
000154627 7001_ $$aPiersimoni, Pierluigi$$b3
000154627 7001_ $$aOdland, Odd Harald$$b4
000154627 7001_ $$aRoehrich, Dieter$$b5
000154627 7001_ $$00000-0002-9335-9076$$aHelstrup, Håvard$$b6
000154627 7001_ $$aPeitzmann, Thomas$$b7
000154627 7001_ $$aUllaland, Kjetil$$b8
000154627 7001_ $$aVarga-Kofarago, Monika$$b9
000154627 7001_ $$aMehendale, Shruti$$b10
000154627 7001_ $$aGrøttvik, Ola Slettevoll$$b11
000154627 7001_ $$aEikeland, Viljar Nilsen$$b12
000154627 7001_ $$aMeric, Ilker$$b13
000154627 7001_ $$0P:(DE-He78)102624aca75cfe987c05343d5fdcf2fe$$aSeco, Joao$$b14$$eLast author$$udkfz
000154627 773__ $$0PERI:(DE-600)1473501-5$$a10.1088/1361-6560/ab8ddb$$n13$$p135012$$tPhysics in medicine and biology$$v65$$x1361-6560$$y2020
000154627 909CO $$ooai:inrepo02.dkfz.de:154627$$pVDB
000154627 9101_ $$0I:(DE-588b)2036810-0$$6P:(DE-He78)84cedecbe48f90adc2a1453780bdaf33$$aDeutsches Krebsforschungszentrum$$b1$$kDKFZ
000154627 9101_ $$0I:(DE-588b)2036810-0$$6P:(DE-He78)102624aca75cfe987c05343d5fdcf2fe$$aDeutsches Krebsforschungszentrum$$b14$$kDKFZ
000154627 9131_ $$0G:(DE-HGF)POF3-315$$1G:(DE-HGF)POF3-310$$2G:(DE-HGF)POF3-300$$3G:(DE-HGF)POF3$$4G:(DE-HGF)POF$$aDE-HGF$$bGesundheit$$lKrebsforschung$$vImaging and radiooncology$$x0
000154627 9141_ $$y2020
000154627 915__ $$0StatID:(DE-HGF)0420$$2StatID$$aNationallizenz
000154627 915__ $$0StatID:(DE-HGF)0430$$2StatID$$aNational-Konsortium
000154627 915__ $$0StatID:(DE-HGF)0100$$2StatID$$aJCR$$bPHYS MED BIOL : 2017
000154627 915__ $$0StatID:(DE-HGF)0200$$2StatID$$aDBCoverage$$bSCOPUS
000154627 915__ $$0StatID:(DE-HGF)0300$$2StatID$$aDBCoverage$$bMedline
000154627 915__ $$0StatID:(DE-HGF)0600$$2StatID$$aDBCoverage$$bEbsco Academic Search
000154627 915__ $$0StatID:(DE-HGF)0030$$2StatID$$aPeer Review$$bASC
000154627 915__ $$0StatID:(DE-HGF)0199$$2StatID$$aDBCoverage$$bClarivate Analytics Master Journal List
000154627 915__ $$0StatID:(DE-HGF)0110$$2StatID$$aWoS$$bScience Citation Index
000154627 915__ $$0StatID:(DE-HGF)0150$$2StatID$$aDBCoverage$$bWeb of Science Core Collection
000154627 915__ $$0StatID:(DE-HGF)0111$$2StatID$$aWoS$$bScience Citation Index Expanded
000154627 915__ $$0StatID:(DE-HGF)1030$$2StatID$$aDBCoverage$$bCurrent Contents - Life Sciences
000154627 915__ $$0StatID:(DE-HGF)1050$$2StatID$$aDBCoverage$$bBIOSIS Previews
000154627 915__ $$0StatID:(DE-HGF)9900$$2StatID$$aIF < 5
000154627 9202_ $$0I:(DE-He78)E041-20160331$$kE041$$lE041 Medizinische Physik in der Radioonkologie$$x0
000154627 9201_ $$0I:(DE-He78)E041-20160331$$kE041$$lE041 Medizinische Physik in der Radioonkologie$$x0
000154627 980__ $$ajournal
000154627 980__ $$aVDB
000154627 980__ $$aI:(DE-He78)E041-20160331
000154627 980__ $$aUNRESTRICTED