001     119277
005     20240228145431.0
024 7 _ |2 doi
|a 10.1002/mrm.26092
024 7 _ |2 pmid
|a pmid:26715361
024 7 _ |2 ISSN
|a 0740-3194
024 7 _ |2 ISSN
|a 1522-2594
024 7 _ |a altmetric:4938504
|2 altmetric
037 _ _ |a DKFZ-2017-00063
041 _ _ |a eng
082 _ _ |a 610
100 1 _ |0 P:(DE-HGF)0
|a Mueller, Lars
|b 0
|e First author
245 _ _ |a Eddy current compensated double diffusion encoded (DDE) MRI.
260 _ _ |a New York, NY [u.a.]
|b Wiley-Liss
|c 2017
336 7 _ |2 DRIVER
|a article
336 7 _ |2 DataCite
|a Output Types/Journal article
336 7 _ |0 PUB:(DE-HGF)16
|2 PUB:(DE-HGF)
|a Journal Article
|b journal
|m journal
|s 1511273756_9921
336 7 _ |2 BibTeX
|a ARTICLE
336 7 _ |2 ORCID
|a JOURNAL_ARTICLE
336 7 _ |0 0
|2 EndNote
|a Journal Article
520 _ _ |a Eddy currents might lead to image distortions in diffusion-weighted echo planar imaging. A method is proposed to reduce their effects on double diffusion encoding (DDE) MRI experiments and the thereby derived microscopic fractional anisotropy (μFA).The twice-refocused spin echo scheme was adapted for DDE measurements. To assess the effect of individual diffusion encodings on the image distortions, measurements of a grid of plastic rods in water were performed. The effect of eddy current compensation on μFA measurements was evaluated in the brains of six healthy volunteers.The use of an eddy current compensation reduced the signal variation. As expected, the distortions caused by the second encoding were larger than those of the first encoding, entailing a stronger need to compensate for them. For an optimal result, however, both encodings had to be compensated. The artifact reduction strongly improved the measurement of the μFA in ventricles and gray matter by reducing the overestimation. An effect of the compensation on absolute μFA values in white matter was not observed.It is advisable to compensate both encodings in DDE measurements for eddy currents. Magn Reson Med 77:328-335, 2017. © 2015 Wiley Periodicals, Inc.
536 _ _ |0 G:(DE-HGF)POF3-315
|a 315 - Imaging and radiooncology (POF3-315)
|c POF3-315
|f POF III
|x 0
588 _ _ |a Dataset connected to CrossRef, PubMed,
700 1 _ |0 P:(DE-HGF)0
|a Wetscherek, Andreas
|b 1
700 1 _ |0 P:(DE-He78)59dfdd0ee0a7f0db81535f0781a3a6d6
|a Kuder, Tristan Anselm
|b 2
|u dkfz
700 1 _ |0 P:(DE-He78)b709e6df1ec6b63e5ffad4c8131f6f4d
|a Laun, Frederik
|b 3
|e Last author
|u dkfz
773 _ _ |0 PERI:(DE-600)1493786-4
|a 10.1002/mrm.26092
|g Vol. 77, no. 1, p. 328 - 335
|n 1
|p 328 - 335
|t Magnetic resonance in medicine
|v 77
|x 0740-3194
|y 2017
909 C O |o oai:inrepo02.dkfz.de:119277
|p VDB
910 1 _ |0 I:(DE-588b)2036810-0
|6 P:(DE-HGF)0
|a Deutsches Krebsforschungszentrum
|b 0
|k DKFZ
910 1 _ |0 I:(DE-588b)2036810-0
|6 P:(DE-HGF)0
|a Deutsches Krebsforschungszentrum
|b 1
|k DKFZ
910 1 _ |0 I:(DE-588b)2036810-0
|6 P:(DE-He78)59dfdd0ee0a7f0db81535f0781a3a6d6
|a Deutsches Krebsforschungszentrum
|b 2
|k DKFZ
910 1 _ |0 I:(DE-588b)2036810-0
|6 P:(DE-He78)b709e6df1ec6b63e5ffad4c8131f6f4d
|a Deutsches Krebsforschungszentrum
|b 3
|k DKFZ
913 1 _ |0 G:(DE-HGF)POF3-315
|1 G:(DE-HGF)POF3-310
|2 G:(DE-HGF)POF3-300
|a DE-HGF
|l Krebsforschung
|v Imaging and radiooncology
|x 0
|4 G:(DE-HGF)POF
|3 G:(DE-HGF)POF3
|b Gesundheit
914 1 _ |y 2017
915 _ _ |0 StatID:(DE-HGF)0420
|2 StatID
|a Nationallizenz
915 _ _ |0 StatID:(DE-HGF)0100
|2 StatID
|a JCR
|b MAGN RESON MED : 2015
915 _ _ |0 StatID:(DE-HGF)0200
|2 StatID
|a DBCoverage
|b SCOPUS
915 _ _ |0 StatID:(DE-HGF)0300
|2 StatID
|a DBCoverage
|b Medline
915 _ _ |0 StatID:(DE-HGF)0199
|2 StatID
|a DBCoverage
|b Thomson Reuters Master Journal List
915 _ _ |0 StatID:(DE-HGF)0110
|2 StatID
|a WoS
|b Science Citation Index
915 _ _ |0 StatID:(DE-HGF)0150
|2 StatID
|a DBCoverage
|b Web of Science Core Collection
915 _ _ |0 StatID:(DE-HGF)0111
|2 StatID
|a WoS
|b Science Citation Index Expanded
915 _ _ |0 StatID:(DE-HGF)1110
|2 StatID
|a DBCoverage
|b Current Contents - Clinical Medicine
915 _ _ |0 StatID:(DE-HGF)1030
|2 StatID
|a DBCoverage
|b Current Contents - Life Sciences
915 _ _ |0 StatID:(DE-HGF)1050
|2 StatID
|a DBCoverage
|b BIOSIS Previews
915 _ _ |0 StatID:(DE-HGF)9900
|2 StatID
|a IF < 5
920 1 _ |0 I:(DE-He78)E020-20160331
|k E020
|l Medizinische Physik in der Radiologie
|x 0
980 _ _ |a journal
980 _ _ |a VDB
980 _ _ |a I:(DE-He78)E020-20160331
980 _ _ |a UNRESTRICTED


LibraryCollectionCLSMajorCLSMinorLanguageAuthor
Marc 21