000131732 001__ 131732
000131732 005__ 20240229105010.0
000131732 0247_ $$2doi$$a10.1002/mrm.26650
000131732 0247_ $$2pmid$$apmid:28266079
000131732 0247_ $$2ISSN$$a0740-3194
000131732 0247_ $$2ISSN$$a1522-2594
000131732 037__ $$aDKFZ-2018-00038
000131732 041__ $$aeng
000131732 082__ $$a610
000131732 1001_ $$aNoureddine, Yacine$$b0
000131732 245__ $$aIn vitro and in silico assessment of RF-induced heating around intracranial aneurysm clips at 7 Tesla.
000131732 260__ $$aNew York, NY [u.a.]$$bWiley-Liss$$c2018
000131732 3367_ $$2DRIVER$$aarticle
000131732 3367_ $$2DataCite$$aOutput Types/Journal article
000131732 3367_ $$0PUB:(DE-HGF)16$$2PUB:(DE-HGF)$$aJournal Article$$bjournal$$mjournal$$s1521456830_12159
000131732 3367_ $$2BibTeX$$aARTICLE
000131732 3367_ $$2ORCID$$aJOURNAL_ARTICLE
000131732 3367_ $$00$$2EndNote$$aJournal Article
000131732 520__ $$aTo examine radiofrequency-induced tissue heating around intracranial aneurysm clips during a 7 Tesla (T) head MR examination.Radiofrequency (RF), temperature simulations, and RF measurements were employed to investigate the effects of polarization and clip length on the electric field (E-field) and temperature. Heating in body models was studied using both a conservative approach and realistic exposure scenarios.Worst-case orientation was found for clips aligned parallel to the E-field polarization. Absolute tissue temperature remained below International Electrotechnical Commission regulatory limits for 44 of 50 clinical scenarios. No significant effect on heating was determined for clip lengths below 18.8 mm, and worst-case heating was found for clip length 51.5 mm. The conservative approach led to a maximum permissible E-field of 72 V/m corresponding to B1+ of 1.2 µT, and an accepted power of 4.6 W for the considered RF head coil instead of 38.5 W without clip.Safe scanning conditions with respect to RF-induced heating can be applied depending on the information about the clip gained during screening interviews. However, force and torque measurements in the MR system shall be conducted to give a final statement on the MR safety of aneurysm clips at 7T. Magn Reson Med 79:568-581, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
000131732 536__ $$0G:(DE-HGF)POF3-315$$a315 - Imaging and radiooncology (POF3-315)$$cPOF3-315$$fPOF III$$x0
000131732 588__ $$aDataset connected to CrossRef, PubMed,
000131732 7001_ $$aKraff, Oliver$$b1
000131732 7001_ $$0P:(DE-He78)022611a2317e4de40fd912e0a72293a8$$aLadd, Mark$$b2$$udkfz
000131732 7001_ $$aWrede, Karsten H$$b3
000131732 7001_ $$aChen, Bixia$$b4
000131732 7001_ $$aQuick, Harald H$$b5
000131732 7001_ $$aSchaefers, Gregor$$b6
000131732 7001_ $$0P:(DE-He78)4444ba69faa9240d7ec86ed09e6ca04e$$aBitz, Andreas$$b7$$eLast author$$udkfz
000131732 773__ $$0PERI:(DE-600)1493786-4$$a10.1002/mrm.26650$$gVol. 79, no. 1, p. 568 - 581$$n1$$p568 - 581$$tMagnetic resonance in medicine$$v79$$x0740-3194$$y2018
000131732 909CO $$ooai:inrepo02.dkfz.de:131732$$pVDB
000131732 9101_ $$0I:(DE-588b)2036810-0$$6P:(DE-He78)022611a2317e4de40fd912e0a72293a8$$aDeutsches Krebsforschungszentrum$$b2$$kDKFZ
000131732 9101_ $$0I:(DE-588b)2036810-0$$6P:(DE-He78)4444ba69faa9240d7ec86ed09e6ca04e$$aDeutsches Krebsforschungszentrum$$b7$$kDKFZ
000131732 9131_ $$0G:(DE-HGF)POF3-315$$1G:(DE-HGF)POF3-310$$2G:(DE-HGF)POF3-300$$3G:(DE-HGF)POF3$$4G:(DE-HGF)POF$$aDE-HGF$$bGesundheit$$lKrebsforschung$$vImaging and radiooncology$$x0
000131732 9141_ $$y2018
000131732 915__ $$0StatID:(DE-HGF)0420$$2StatID$$aNationallizenz
000131732 915__ $$0StatID:(DE-HGF)0100$$2StatID$$aJCR$$bMAGN RESON MED : 2015
000131732 915__ $$0StatID:(DE-HGF)0200$$2StatID$$aDBCoverage$$bSCOPUS
000131732 915__ $$0StatID:(DE-HGF)0300$$2StatID$$aDBCoverage$$bMedline
000131732 915__ $$0StatID:(DE-HGF)0199$$2StatID$$aDBCoverage$$bThomson Reuters Master Journal List
000131732 915__ $$0StatID:(DE-HGF)0110$$2StatID$$aWoS$$bScience Citation Index
000131732 915__ $$0StatID:(DE-HGF)0150$$2StatID$$aDBCoverage$$bWeb of Science Core Collection
000131732 915__ $$0StatID:(DE-HGF)0111$$2StatID$$aWoS$$bScience Citation Index Expanded
000131732 915__ $$0StatID:(DE-HGF)1110$$2StatID$$aDBCoverage$$bCurrent Contents - Clinical Medicine
000131732 915__ $$0StatID:(DE-HGF)1030$$2StatID$$aDBCoverage$$bCurrent Contents - Life Sciences
000131732 915__ $$0StatID:(DE-HGF)1050$$2StatID$$aDBCoverage$$bBIOSIS Previews
000131732 915__ $$0StatID:(DE-HGF)9900$$2StatID$$aIF < 5
000131732 9201_ $$0I:(DE-He78)E020-20160331$$kE020$$lMedizinische Physik in der Radiologie$$x0
000131732 980__ $$ajournal
000131732 980__ $$aVDB
000131732 980__ $$aI:(DE-He78)E020-20160331
000131732 980__ $$aUNRESTRICTED