000153435 245__ $$aA technique for spatial resolution improvement in helium-beam radiography.
000153435 260__ $$aCollege Park, Md.$$bAAPM$$c2020
000153435 3367_ $$2DRIVER$$aarticle
000153435 3367_ $$2DataCite$$aOutput Types/Journal article
000153435 3367_ $$0PUB:(DE-HGF)16$$2PUB:(DE-HGF)$$aJournal Article$$bjournal$$mjournal$$s1601299731_21251
000153435 3367_ $$2BibTeX$$aARTICLE
000153435 3367_ $$2ORCID$$aJOURNAL_ARTICLE
000153435 3367_ $$00$$2EndNote$$aJournal Article
000153435 500__ $$a2020 Jun;47(5):2212-2221#EA:E040#LA:E040#
000153435 520__ $$aIon-beam radiography exhibits a significantly lower spatial resolution (SR) compared to X-ray radiography. This is mostly due the multiple Coulomb scattering (MCS) that the ions undergo in the imaged object. In this work, a novel technique to improve the spatial resolution in helium-beam radiography was developed. Increasing helium-beam energies were exploited in order to decrease the MCS, and therefore increase the SR.The experimental investigation was carried out with a dedicated ion-tracking imaging system fully composed of thin, pixelated silicon detectors (Timepix). Four helium beams with increasing energies (from 168.8MeV/u to 220.5MeV/u) were used to image a homogeneous 160mm PMMA phantom with a 2mm air gap at middle depth. An energy degrader was placed between the rear tracking system and the energy-deposition detector to compensate for the longer range associated with more energetic ions. The SR was measured for each beam energy. To take into account the overall impact on the image quality, the contrast-to-noise ratio (CNR), the single-ion water equivalent thickness (WET) precision and the absorbed dose in the phantom were also evaluated as a function of the initial beam energy. FLUKA Monte Carlo simulations were used to support the conceptual design of the experimental setup and for dose estimation.In the investigated energy interval, a total SR increase by around 30% was measured with increasing beam energy, reaching a maximum value of 0.69 lp/mm. For radiographs generated with 350 μGy of absorbed dose and 220 μm pixel size, a CNR decrease of 32% was found as the beam energy increases. For 1mm pixel size, the CNR decreases only by 22%. The CNR of the images was always above 6. The single-ion WET precision was found to be in a range between 1.2% and 1.5 %.We have experimentally shown and quantified the possibility of improving SR in helium-beam radiography by using increasing beam energies in combination with an energy degrader. A significant SR increase was measured with an acceptable decrease of CNR. Furthermore, we have shown that an energy degrader can be a valuable tool to exploit increasing beam energies to generate energy-deposition radiographs.
000153435 536__ $$0G:(DE-HGF)POF3-315$$a315 - Imaging and radiooncology (POF3-315)$$cPOF3-315$$fPOF III$$x0
000153435 588__ $$aDataset connected to CrossRef, PubMed,
000153435 7001_ $$0P:(DE-He78)dfe82ba00edb8b1609794fbe37bd616f$$aMartisikova, M.$$b1$$udkfz
000153435 7001_ $$0P:(DE-He78)4af90cacc534bcab08c5a70badbb2d5e$$aGehrke, Tim$$b2$$eLast author$$udkfz
000153435 773__ $$0PERI:(DE-600)1466421-5$$a10.1002/mp.14051$$gp. mp.14051$$n5$$p2212-2221$$tMedical physics$$v47$$x2473-4209$$y2020
000153435 909CO $$ooai:inrepo02.dkfz.de:153435$$pVDB
000153435 9101_ $$0I:(DE-588b)2036810-0$$6P:(DE-He78)3854ab5f68f575f5984749b6aa09330c$$aDeutsches Krebsforschungszentrum$$b0$$kDKFZ
000153435 9101_ $$0I:(DE-588b)2036810-0$$6P:(DE-He78)dfe82ba00edb8b1609794fbe37bd616f$$aDeutsches Krebsforschungszentrum$$b1$$kDKFZ
000153435 9101_ $$0I:(DE-588b)2036810-0$$6P:(DE-He78)4af90cacc534bcab08c5a70badbb2d5e$$aDeutsches Krebsforschungszentrum$$b2$$kDKFZ
000153435 9131_ $$0G:(DE-HGF)POF3-315$$1G:(DE-HGF)POF3-310$$2G:(DE-HGF)POF3-300$$3G:(DE-HGF)POF3$$4G:(DE-HGF)POF$$aDE-HGF$$bGesundheit$$lKrebsforschung$$vImaging and radiooncology$$x0
000153435 9141_ $$y2020
000153435 915__ $$0StatID:(DE-HGF)0300$$2StatID$$aDBCoverage$$bMedline
000153435 915__ $$0StatID:(DE-HGF)0320$$2StatID$$aDBCoverage$$bPubMed Central
000153435 915__ $$0StatID:(DE-HGF)0100$$2StatID$$aJCR$$bMED PHYS : 2017
000153435 915__ $$0StatID:(DE-HGF)0200$$2StatID$$aDBCoverage$$bSCOPUS
000153435 915__ $$0StatID:(DE-HGF)0600$$2StatID$$aDBCoverage$$bEbsco Academic Search
000153435 915__ $$0StatID:(DE-HGF)0030$$2StatID$$aPeer Review$$bASC
000153435 915__ $$0StatID:(DE-HGF)0199$$2StatID$$aDBCoverage$$bClarivate Analytics Master Journal List
000153435 915__ $$0StatID:(DE-HGF)0110$$2StatID$$aWoS$$bScience Citation Index
000153435 915__ $$0StatID:(DE-HGF)0150$$2StatID$$aDBCoverage$$bWeb of Science Core Collection
000153435 915__ $$0StatID:(DE-HGF)0111$$2StatID$$aWoS$$bScience Citation Index Expanded
000153435 915__ $$0StatID:(DE-HGF)1110$$2StatID$$aDBCoverage$$bCurrent Contents - Clinical Medicine
000153435 915__ $$0StatID:(DE-HGF)1030$$2StatID$$aDBCoverage$$bCurrent Contents - Life Sciences
000153435 915__ $$0StatID:(DE-HGF)9900$$2StatID$$aIF < 5
000153435 9202_ $$0I:(DE-He78)E040-20160331$$kE040$$lE040 Med. Physik in der Strahlentherapie$$x0
000153435 9200_ $$0I:(DE-He78)E040-20160331$$kE040$$lE040 Med. Physik in der Strahlentherapie$$x0
000153435 9201_ $$0I:(DE-He78)E040-20160331$$kE040$$lE040 Med. Physik in der Strahlentherapie$$x0
000153435 980__ $$ajournal
000153435 980__ $$aVDB
000153435 980__ $$aI:(DE-He78)E040-20160331
000153435 980__ $$aUNRESTRICTED