001     154614
005     20240229123107.0
024 7 _ |a 10.1038/s41598-020-63215-0
|2 doi
024 7 _ |a pmid:32332815
|2 pmid
024 7 _ |a altmetric:80620975
|2 altmetric
037 _ _ |a DKFZ-2020-00887
041 _ _ |a eng
082 _ _ |a 600
100 1 _ |a Magalhaes Martins, Paulo Jorge
|0 P:(DE-He78)71030cceec72df4f96fb0ec3eef072f3
|b 0
|e First author
|u dkfz
245 _ _ |a PIBS: Proton and ion beam spectroscopy for in vivo measurements of oxygen, carbon, and calcium concentrations in the human body.
260 _ _ |a [London]
|c 2020
|b Macmillan Publishers Limited, part of Springer Nature
336 7 _ |a article
|2 DRIVER
336 7 _ |a Output Types/Journal article
|2 DataCite
336 7 _ |a Journal Article
|b journal
|m journal
|0 PUB:(DE-HGF)16
|s 1600861645_6352
|2 PUB:(DE-HGF)
336 7 _ |a ARTICLE
|2 BibTeX
336 7 _ |a JOURNAL_ARTICLE
|2 ORCID
336 7 _ |a Journal Article
|0 0
|2 EndNote
500 _ _ |a #EA:E041#LA:E041#
520 _ _ |a Proton and ion beam therapy has proven to benefit tumour control with lower side-effects, mostly in paediatrics. Here we demonstrate a feasible technique for proton and ion beam spectroscopy (PIBS) capable of determining the elemental compositions of the irradiated tissues during particle therapy. This follows the developments in prompt gamma imaging for online range verification and the inheritance from prompt gamma neutron activation analysis. Samples of water solutions were prepared to emulate varying oxygen and carbon concentrations. The irradiation of those samples and other tissue surrogate inserts by protons and ion beams under clinical conditions clearly showed a logarithmic relationship between the target elemental composition and the prompt gamma production. This finding is in line with the known logarithmic dependence of the pH with the proton molar concentration. Elemental concentration changes of 1% for calcium and 2% for oxygen in adipose, brain, breast, liver, muscle and bone-related tissue surrogates were clearly identified. Real-time in vivo measurements of oxygen, carbon and calcium concentrations will be evaluated in a pre-clinical and clinical environment. This technique should have an important impact in the assessment of tumour hypoxia over the course of several treatment fractions and the tracking of calcifications in brain metastases.
536 _ _ |a 315 - Imaging and radiooncology (POF3-315)
|0 G:(DE-HGF)POF3-315
|c POF3-315
|f POF III
|x 0
588 _ _ |a Dataset connected to CrossRef, PubMed,
700 1 _ |a Dal Bello, Riccardo
|0 P:(DE-He78)ca98a31afd9fff038336ecfcf56f268c
|b 1
|u dkfz
700 1 _ |a Ackermann, Benjamin
|b 2
700 1 _ |a Brons, Stephan
|b 3
700 1 _ |a Hermann, German
|b 4
700 1 _ |a Kihm, Thomas
|b 5
700 1 _ |a Seco, Joao
|0 P:(DE-He78)102624aca75cfe987c05343d5fdcf2fe
|b 6
|e Last author
|u dkfz
773 _ _ |a 10.1038/s41598-020-63215-0
|g Vol. 10, no. 1, p. 7007
|0 PERI:(DE-600)2615211-3
|n 1
|p 7007
|t Scientific reports
|v 10
|y 2020
|x 2045-2322
909 C O |p VDB
|o oai:inrepo02.dkfz.de:154614
910 1 _ |a Deutsches Krebsforschungszentrum
|0 I:(DE-588b)2036810-0
|k DKFZ
|b 0
|6 P:(DE-He78)71030cceec72df4f96fb0ec3eef072f3
910 1 _ |a Deutsches Krebsforschungszentrum
|0 I:(DE-588b)2036810-0
|k DKFZ
|b 1
|6 P:(DE-He78)ca98a31afd9fff038336ecfcf56f268c
910 1 _ |a Deutsches Krebsforschungszentrum
|0 I:(DE-588b)2036810-0
|k DKFZ
|b 6
|6 P:(DE-He78)102624aca75cfe987c05343d5fdcf2fe
913 1 _ |a DE-HGF
|l Krebsforschung
|1 G:(DE-HGF)POF3-310
|0 G:(DE-HGF)POF3-315
|2 G:(DE-HGF)POF3-300
|v Imaging and radiooncology
|x 0
|4 G:(DE-HGF)POF
|3 G:(DE-HGF)POF3
|b Gesundheit
914 1 _ |y 2020
915 _ _ |a JCR
|0 StatID:(DE-HGF)0100
|2 StatID
|b SCI REP-UK : 2017
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0200
|2 StatID
|b SCOPUS
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0300
|2 StatID
|b Medline
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0310
|2 StatID
|b NCBI Molecular Biology Database
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0320
|2 StatID
|b PubMed Central
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0501
|2 StatID
|b DOAJ Seal
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0500
|2 StatID
|b DOAJ
915 _ _ |a Peer Review
|0 StatID:(DE-HGF)0030
|2 StatID
|b DOAJ : Blind peer review
915 _ _ |a Creative Commons Attribution CC BY (No Version)
|0 LIC:(DE-HGF)CCBYNV
|2 V:(DE-HGF)
|b DOAJ
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0600
|2 StatID
|b Ebsco Academic Search
915 _ _ |a Peer Review
|0 StatID:(DE-HGF)0030
|2 StatID
|b ASC
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0199
|2 StatID
|b Clarivate Analytics Master Journal List
915 _ _ |a WoS
|0 StatID:(DE-HGF)0110
|2 StatID
|b Science Citation Index
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0150
|2 StatID
|b Web of Science Core Collection
915 _ _ |a WoS
|0 StatID:(DE-HGF)0111
|2 StatID
|b Science Citation Index Expanded
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)1150
|2 StatID
|b Current Contents - Physical, Chemical and Earth Sciences
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)1040
|2 StatID
|b Zoological Record
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)1050
|2 StatID
|b BIOSIS Previews
915 _ _ |a IF < 5
|0 StatID:(DE-HGF)9900
|2 StatID
920 2 _ |0 I:(DE-He78)E041-20160331
|k E041
|l E041 Medizinische Physik in der Radioonkologie
|x 0
920 0 _ |0 I:(DE-He78)E041-20160331
|k E041
|l E041 Medizinische Physik in der Radioonkologie
|x 0
920 1 _ |0 I:(DE-He78)E041-20160331
|k E041
|l E041 Medizinische Physik in der Radioonkologie
|x 0
980 _ _ |a journal
980 _ _ |a VDB
980 _ _ |a I:(DE-He78)E041-20160331
980 _ _ |a UNRESTRICTED


LibraryCollectionCLSMajorCLSMinorLanguageAuthor
Marc 21