001     167634
005     20240229133545.0
024 7 _ |a 10.1002/mrm.28745
|2 doi
024 7 _ |a pmid:33634505
|2 pmid
024 7 _ |a 0740-3194
|2 ISSN
024 7 _ |a 1522-2594
|2 ISSN
024 7 _ |a altmetric:102021256
|2 altmetric
037 _ _ |a DKFZ-2021-00468
041 _ _ |a English
082 _ _ |a 610
100 1 _ |a Liebert, Andrzej
|0 0000-0002-8450-3021
|b 0
245 _ _ |a Whole-brain quantitative CEST MRI at 7T using parallel transmission methods and B 1 + correction.
260 _ _ |a New York, NY [u.a.]
|c 2021
|b Wiley-Liss
336 7 _ |a article
|2 DRIVER
336 7 _ |a Output Types/Journal article
|2 DataCite
336 7 _ |a Journal Article
|b journal
|m journal
|0 PUB:(DE-HGF)16
|s 1625049788_24032
|2 PUB:(DE-HGF)
336 7 _ |a ARTICLE
|2 BibTeX
336 7 _ |a JOURNAL_ARTICLE
|2 ORCID
336 7 _ |a Journal Article
|0 0
|2 EndNote
500 _ _ |a #LA:E020# / 86(1):346-362
520 _ _ |a To enable whole-brain quantitative CEST MRI at ultra-high magnetic field strengths (B0 ≥ 7T) within short acquisition times.Multiple interleaved mode saturation (MIMOSA) was combined with fast online-customized (FOCUS) parallel transmission (pTx) excitation pulses and B 1 + correction to achieve homogenous whole-brain coverage. Examinations of 13 volunteers were performed on a 7T MRI system with 3 different types of pulse sequences: (1) saturation in circular polarized (CP) mode and CP mode readout, (2) MIMOSA and CP readout, and (3) MIMOSA and FOCUS readout. For comparison, the inverse magnetic transfer ratio metric for relayed nuclear Overhauser effect and amide proton transfer were calculated. To investigate the number of required acquisitions for a good B 1 + correction, 4 volunteers were measured with 6 different B1 amplitudes. Finally, time point repeatability was investigated for 6 volunteers.MIMOSA FOCUS sequence using B 1 + correction, with both single and multiple points, reduced inhomogeneity of the CEST contrasts around the occipital lobe and cerebellum. Results indicate that the most stable inter-subject coefficient of variation was achieved using the MIMOSA FOCUS sequence. Time point repeatability of MIMOSA FOCUS with single-point B 1 + correction showed a maximum coefficient of variation below 8% for 3 measurements in a single volunteer.A combination of MIMOSA FOCUS with a single-point B 1 + correction can be used to achieve quantitative CEST measurements at ultra-high magnetic field strengths. Compared to previous B 1 + correction methods, acquisition time can be reduced as additional scans required for B 1 + correction can be omitted.
536 _ _ |a 315 - Bildgebung und Radioonkologie (POF4-315)
|0 G:(DE-HGF)POF4-315
|c POF4-315
|x 0
|f POF IV
588 _ _ |a Dataset connected to CrossRef, PubMed,
650 _ 7 |a 7T
|2 Other
650 _ 7 |a chemical exchange saturation transfer
|2 Other
650 _ 7 |a fast-online customized pulses
|2 Other
650 _ 7 |a multiple interleaved mode saturation
|2 Other
650 _ 7 |a parallel transmission
|2 Other
650 _ 7 |a spiral non-selective trajectory
|2 Other
700 1 _ |a Tkotz, Katharina
|0 0000-0002-0847-2729
|b 1
700 1 _ |a Herrler, Jürgen
|0 0000-0002-4620-8216
|b 2
700 1 _ |a Linz, Peter
|0 0000-0002-8232-1443
|b 3
700 1 _ |a Mennecke, Angelika
|0 0000-0001-6795-5627
|b 4
700 1 _ |a German, Alex
|b 5
700 1 _ |a Liebig, Patrick
|0 0000-0001-7342-3715
|b 6
700 1 _ |a Gumbrecht, Rene
|b 7
700 1 _ |a Schmidt, Manuel
|b 8
700 1 _ |a Doerfler, Arnd
|b 9
700 1 _ |a Uder, Michael
|b 10
700 1 _ |a Zaiss, Moritz
|b 11
700 1 _ |a Nagel, Armin
|0 P:(DE-He78)054fd7a5195b75b11fbdc5c360276011
|b 12
|e Last author
|u dkfz
773 _ _ |a 10.1002/mrm.28745
|g p. mrm.28745
|0 PERI:(DE-600)1493786-4
|n 1
|p 346-362
|t Magnetic resonance in medicine
|v 86
|y 2021
|x 1522-2594
909 C O |o oai:inrepo02.dkfz.de:167634
|p VDB
910 1 _ |a Deutsches Krebsforschungszentrum
|0 I:(DE-588b)2036810-0
|k DKFZ
|b 12
|6 P:(DE-He78)054fd7a5195b75b11fbdc5c360276011
913 0 _ |a DE-HGF
|b Gesundheit
|l Krebsforschung
|1 G:(DE-HGF)POF3-310
|0 G:(DE-HGF)POF3-315
|3 G:(DE-HGF)POF3
|2 G:(DE-HGF)POF3-300
|4 G:(DE-HGF)POF
|v Imaging and radiooncology
|x 0
913 1 _ |a DE-HGF
|b Gesundheit
|l Krebsforschung
|1 G:(DE-HGF)POF4-310
|0 G:(DE-HGF)POF4-315
|3 G:(DE-HGF)POF4
|2 G:(DE-HGF)POF4-300
|4 G:(DE-HGF)POF
|v Bildgebung und Radioonkologie
|x 0
914 1 _ |y 2021
915 _ _ |a Nationallizenz
|0 StatID:(DE-HGF)0420
|2 StatID
|d 2020-09-05
|w ger
915 _ _ |a DEAL Wiley
|0 StatID:(DE-HGF)3001
|2 StatID
|d 2020-09-05
|w ger
915 _ _ |a JCR
|0 StatID:(DE-HGF)0100
|2 StatID
|b MAGN RESON MED : 2018
|d 2020-09-05
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0200
|2 StatID
|b SCOPUS
|d 2020-09-05
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0300
|2 StatID
|b Medline
|d 2020-09-05
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0199
|2 StatID
|b Clarivate Analytics Master Journal List
|d 2020-09-05
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)1030
|2 StatID
|b Current Contents - Life Sciences
|d 2020-09-05
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0160
|2 StatID
|b Essential Science Indicators
|d 2020-09-05
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)1050
|2 StatID
|b BIOSIS Previews
|d 2020-09-05
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)1110
|2 StatID
|b Current Contents - Clinical Medicine
|d 2020-09-05
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)1190
|2 StatID
|b Biological Abstracts
|d 2020-09-05
915 _ _ |a WoS
|0 StatID:(DE-HGF)0113
|2 StatID
|b Science Citation Index Expanded
|d 2020-09-05
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0150
|2 StatID
|b Web of Science Core Collection
|d 2020-09-05
915 _ _ |a IF < 5
|0 StatID:(DE-HGF)9900
|2 StatID
|d 2020-09-05
920 1 _ |0 I:(DE-He78)E020-20160331
|k E020
|l E020 Med. Physik in der Radiologie
|x 0
980 _ _ |a journal
980 _ _ |a VDB
980 _ _ |a I:(DE-He78)E020-20160331
980 _ _ |a UNRESTRICTED


LibraryCollectionCLSMajorCLSMinorLanguageAuthor
Marc 21