000169795 001__ 169795
000169795 005__ 20240229133655.0
000169795 0247_ $$2doi$$a10.1088/2057-1976/ac12a5
000169795 0247_ $$2pmid$$apmid:34237712
000169795 037__ $$aDKFZ-2021-01549
000169795 041__ $$aEnglish
000169795 082__ $$a610
000169795 1001_ $$0P:(DE-He78)d6ff1f04f2e927518e4290cc7dec3133$$aElter, Alina$$b0$$eFirst author$$udkfz
000169795 245__ $$aPAGAT gel dosimetry for everyone: gel production, measurement and evaluation.
000169795 260__ $$aBristol$$bIOP Publ.$$c2021
000169795 3367_ $$2DRIVER$$aarticle
000169795 3367_ $$2DataCite$$aOutput Types/Journal article
000169795 3367_ $$0PUB:(DE-HGF)16$$2PUB:(DE-HGF)$$aJournal Article$$bjournal$$mjournal$$s1640242838_2099
000169795 3367_ $$2BibTeX$$aARTICLE
000169795 3367_ $$2ORCID$$aJOURNAL_ARTICLE
000169795 3367_ $$00$$2EndNote$$aJournal Article
000169795 500__ $$a#EA:E040#LA:E040#
000169795 520__ $$aPolymer gel (PG) dosimetry is a valuable tool to measure complex dose distributions in 3D with a high spatial resolution. However, due to complex protocols that need to be followed for in-house produced PGs and the high costs of commercially available gels, PG gels are only rarely applied in quality assurance procedures worldwide. In this work, we provide an introduction to perform highly standardized dosimetric PG experiments using PAGAT (PolyAcrylamide Gelatine gel fabricated at ATmospheric conditions) dosimetry gel. PAGAT gel can be produced at atmospheric conditions, at low costs and is evaluated using magnetic resonance imaging (MRI). The conduction of PG experiments is described in great detail including the gel production, treatment planning, irradiation, MRI evaluation and post-processing procedure. Furthermore, a plugin in an open source image processing tool for post-processing is provided free of charge that allows a standardized and reproducible analysis of PG experiments.
000169795 536__ $$0G:(DE-HGF)POF4-315$$a315 - Bildgebung und Radioonkologie (POF4-315)$$cPOF4-315$$fPOF IV$$x0
000169795 588__ $$aDataset connected to CrossRef, PubMed, , Journals: inrepo01.inet.dkfz-heidelberg.de
000169795 650_7 $$2Other$$a3D dosimetry
000169795 650_7 $$2Other$$aPAGAT
000169795 650_7 $$2Other$$adosimetry gel evaluation
000169795 650_7 $$2Other$$adosimetry gel production
000169795 650_7 $$2Other$$agel dosimetry
000169795 7001_ $$0P:(DE-He78)e43f53a20835bd25906f1795558151a3$$aDorsch, Stefan$$b1$$udkfz
000169795 7001_ $$0P:(DE-He78)52542b678ef7de402c10e93127590a11$$aThomas, Sarina$$b2$$udkfz
000169795 7001_ $$0P:(DE-He78)0471f134892eed933ba6564245352ae2$$aHentschke, Clemens$$b3
000169795 7001_ $$0P:(DE-He78)f0ab09cfecf353f363bab4cc983de95d$$aFloca, Ralf$$b4$$udkfz
000169795 7001_ $$0P:(DE-He78)3b3ff5cc513dd71b560eb6a18e4d0c07$$aRunz, Armin$$b5$$udkfz
000169795 7001_ $$0P:(DE-He78)b43076fb0a30230e4323887c0c980046$$aKarger, Christian P$$b6$$udkfz
000169795 7001_ $$0P:(DE-He78)d26409e0d07007daf771142a945102ef$$aMann, Philipp$$b7$$eLast author$$udkfz
000169795 773__ $$0PERI:(DE-600)2844309-3$$a10.1088/2057-1976/ac12a5$$n5$$p057001$$tBiomedical physics & engineering express$$v7$$x2057-1976$$y2021
000169795 909CO $$ooai:inrepo02.dkfz.de:169795$$pVDB
000169795 9101_ $$0I:(DE-588b)2036810-0$$6P:(DE-He78)d6ff1f04f2e927518e4290cc7dec3133$$aDeutsches Krebsforschungszentrum$$b0$$kDKFZ
000169795 9101_ $$0I:(DE-588b)2036810-0$$6P:(DE-He78)e43f53a20835bd25906f1795558151a3$$aDeutsches Krebsforschungszentrum$$b1$$kDKFZ
000169795 9101_ $$0I:(DE-588b)2036810-0$$6P:(DE-He78)52542b678ef7de402c10e93127590a11$$aDeutsches Krebsforschungszentrum$$b2$$kDKFZ
000169795 9101_ $$0I:(DE-588b)2036810-0$$6P:(DE-He78)0471f134892eed933ba6564245352ae2$$aDeutsches Krebsforschungszentrum$$b3$$kDKFZ
000169795 9101_ $$0I:(DE-588b)2036810-0$$6P:(DE-He78)f0ab09cfecf353f363bab4cc983de95d$$aDeutsches Krebsforschungszentrum$$b4$$kDKFZ
000169795 9101_ $$0I:(DE-588b)2036810-0$$6P:(DE-He78)3b3ff5cc513dd71b560eb6a18e4d0c07$$aDeutsches Krebsforschungszentrum$$b5$$kDKFZ
000169795 9101_ $$0I:(DE-588b)2036810-0$$6P:(DE-He78)b43076fb0a30230e4323887c0c980046$$aDeutsches Krebsforschungszentrum$$b6$$kDKFZ
000169795 9101_ $$0I:(DE-588b)2036810-0$$6P:(DE-He78)d26409e0d07007daf771142a945102ef$$aDeutsches Krebsforschungszentrum$$b7$$kDKFZ
000169795 9131_ $$0G:(DE-HGF)POF4-315$$1G:(DE-HGF)POF4-310$$2G:(DE-HGF)POF4-300$$3G:(DE-HGF)POF4$$4G:(DE-HGF)POF$$aDE-HGF$$bGesundheit$$lKrebsforschung$$vBildgebung und Radioonkologie$$x0
000169795 9130_ $$0G:(DE-HGF)POF3-315$$1G:(DE-HGF)POF3-310$$2G:(DE-HGF)POF3-300$$3G:(DE-HGF)POF3$$4G:(DE-HGF)POF$$aDE-HGF$$bGesundheit$$lKrebsforschung$$vImaging and radiooncology$$x0
000169795 9141_ $$y2021
000169795 915__ $$0StatID:(DE-HGF)0200$$2StatID$$aDBCoverage$$bSCOPUS$$d2020-08-22
000169795 915__ $$0StatID:(DE-HGF)0300$$2StatID$$aDBCoverage$$bMedline$$d2020-08-22
000169795 915__ $$0StatID:(DE-HGF)0199$$2StatID$$aDBCoverage$$bClarivate Analytics Master Journal List$$d2020-08-22
000169795 915__ $$0StatID:(DE-HGF)0112$$2StatID$$aWoS$$bEmerging Sources Citation Index$$d2020-08-22
000169795 915__ $$0StatID:(DE-HGF)0150$$2StatID$$aDBCoverage$$bWeb of Science Core Collection$$d2020-08-22
000169795 9201_ $$0I:(DE-He78)E040-20160331$$kE040$$lE040 Med. Physik in der Strahlentherapie$$x0
000169795 9201_ $$0I:(DE-He78)E230-20160331$$kE230$$lE230 Medizinische Bildverarbeitung$$x1
000169795 980__ $$ajournal
000169795 980__ $$aVDB
000169795 980__ $$aI:(DE-He78)E040-20160331
000169795 980__ $$aI:(DE-He78)E230-20160331
000169795 980__ $$aUNRESTRICTED