000275924 001__ 275924
000275924 005__ 20240229154948.0
000275924 0247_ $$2doi$$a10.1002/mp.16432
000275924 0247_ $$2pmid$$apmid:37145971
000275924 0247_ $$2ISSN$$a0094-2405
000275924 0247_ $$2ISSN$$a1522-8541
000275924 0247_ $$2ISSN$$a2473-4209
000275924 0247_ $$2altmetric$$aaltmetric:147726751
000275924 037__ $$aDKFZ-2023-00912
000275924 041__ $$aEnglish
000275924 082__ $$a610
000275924 1001_ $$0P:(DE-He78)5d3fd2061719ec17ba3c894c81dbde89$$aStengl, Christina$$b0$$eFirst author$$udkfz
000275924 245__ $$aDevelopment and characterization of a versatile mini-beam collimator for pre-clinical photon beam irradiation.
000275924 260__ $$aCollege Park, Md.$$bAAPM$$c2023
000275924 3367_ $$2DRIVER$$aarticle
000275924 3367_ $$2DataCite$$aOutput Types/Journal article
000275924 3367_ $$0PUB:(DE-HGF)16$$2PUB:(DE-HGF)$$aJournal Article$$bjournal$$mjournal$$s1692102220_941
000275924 3367_ $$2BibTeX$$aARTICLE
000275924 3367_ $$2ORCID$$aJOURNAL_ARTICLE
000275924 3367_ $$00$$2EndNote$$aJournal Article
000275924 500__ $$a#EA:E040#LA:E040#LA:E041# / 2023 Aug;50(8):5222-5237
000275924 520__ $$aInterest in spatial fractionation radiotherapy has exponentially increased over the last decade as a significant reduction of healthy tissue toxicity was observed by mini-beam irradiation. Published studies, however, mostly use rigid mini-beam collimators dedicated to their exact experimental arrangement such that changing the setup or testing new mini-beam collimator configurations becomes challenging and expensive.In this work, a versatile, low-cost mini-beam collimator was designed and manufactured for pre-clinical applications with X-ray beams. The mini-beam collimator enables variability of the full width at half maximum (FWHM), the center-to-center distance (ctc), the peak-to-valley dose ratio (PVDR), and the source-to-collimator distance (SCD).The mini-beam collimator is an in-house development, which was constructed of 10 × 40 mm2 tungsten or brass plates. These metal plates were combined with 3D-printed plastic plates that can be stacked together in the desired order. A standard X-ray source was used for the dosimetric characterization of four different configurations of the collimator, including a combination of plastic plates of 0.5, 1, or 2 mm width, assembled with 1 or 2 mm thick metal plates. Irradiations were done at three different SCDs for characterizing the performance of the collimator. For the SCDs closer to the radiation source, the plastic plates were 3D-printed with a dedicated angle to compensate for the X-ray beam divergence, making it possible to study ultra-high dose rates of around 40 Gy/s. All dosimetric quantifications were performed using EBT-XD films. Additionally, in vitro studies with H460 cells were carried out.Characteristic mini-beam dose distributions were obtained with the developed collimator using a conventional X-ray source. With the exchangeable 3D-printed plates, FWHM and ctc from 0.52 to 2.11 mm, and from 1.77 to 4.61 mm were achieved, with uncertainties ranging from 0.01% to 8.98%, respectively. The FWHM and ctc obtained with the EBT-XD films are in agreement with the design of each mini-beam collimator configuration. For dose rates in the order of several Gy/min, the highest PVDR of 10.09 ± 1.08 was achieved with a collimator configuration of 0.5 mm thick plastic plates and 2 mm thick metal plates. Exchanging the tungsten plates with the lower-density metal brass reduced the PVDR by approximately 50%. Also, increasing the dose rate to ultra-high dose rates was feasible with the mini-beam collimator, where a PVDR of 24.26 ± 2.10 was achieved. Finally, it was possible to deliver and quantify mini-beam dose distribution patterns in vitro.With the developed collimator, we achieved various mini-beam dose distributions that can be adjusted according to the needs of the user in regards to FWHM, ctc, PVDR and SCD, while accounting for beam divergence. Therefore, the designed mini-beam collimator may enable low-cost and versatile pre-clinical research on mini-beam irradiation.
000275924 536__ $$0G:(DE-HGF)POF4-315$$a315 - Bildgebung und Radioonkologie (POF4-315)$$cPOF4-315$$fPOF IV$$x0
000275924 588__ $$aDataset connected to CrossRef, PubMed, , Journals: inrepo02.dkfz.de
000275924 650_7 $$2Other$$a3D printing
000275924 650_7 $$2Other$$adosimetry
000275924 650_7 $$2Other$$amini-beam collimator
000275924 650_7 $$2Other$$aspatial fractionation
000275924 7001_ $$0P:(DE-He78)1621d54eaa742202b414214818b3df4e$$aArbes, Eric$$b1$$udkfz
000275924 7001_ $$0P:(DE-He78)5889f9564a2c825325847329373b61ac$$aThai, Long-Yang Jan$$b2$$udkfz
000275924 7001_ $$0P:(DE-He78)5ce5a852e39ce8846d820376eb30697e$$aEchner, Gernot$$b3$$udkfz
000275924 7001_ $$0P:(DE-He78)d028533bf57b4053bc9b94b70daab443$$aVedelago, José$$b4$$udkfz
000275924 7001_ $$0P:(DE-He78)02e29e2d540ff21d777f3a03ec9f5ade$$aJansen, Jeannette$$b5$$udkfz
000275924 7001_ $$0P:(DE-He78)440a3f62ea9ea5c63375308976fc4c44$$aJäkel, Oliver$$b6$$eLast author$$udkfz
000275924 7001_ $$0P:(DE-He78)102624aca75cfe987c05343d5fdcf2fe$$aSeco, Joao$$b7$$eLast author$$udkfz
000275924 773__ $$0PERI:(DE-600)1466421-5$$a10.1002/mp.16432$$gp. mp.16432$$n8$$p5222-5237$$tMedical physics$$v50$$x0094-2405$$y2023
000275924 909CO $$ooai:inrepo02.dkfz.de:275924$$pVDB
000275924 9101_ $$0I:(DE-588b)2036810-0$$6P:(DE-He78)5d3fd2061719ec17ba3c894c81dbde89$$aDeutsches Krebsforschungszentrum$$b0$$kDKFZ
000275924 9101_ $$0I:(DE-588b)2036810-0$$6P:(DE-He78)1621d54eaa742202b414214818b3df4e$$aDeutsches Krebsforschungszentrum$$b1$$kDKFZ
000275924 9101_ $$0I:(DE-588b)2036810-0$$6P:(DE-He78)5889f9564a2c825325847329373b61ac$$aDeutsches Krebsforschungszentrum$$b2$$kDKFZ
000275924 9101_ $$0I:(DE-588b)2036810-0$$6P:(DE-He78)5ce5a852e39ce8846d820376eb30697e$$aDeutsches Krebsforschungszentrum$$b3$$kDKFZ
000275924 9101_ $$0I:(DE-588b)2036810-0$$6P:(DE-He78)d028533bf57b4053bc9b94b70daab443$$aDeutsches Krebsforschungszentrum$$b4$$kDKFZ
000275924 9101_ $$0I:(DE-588b)2036810-0$$6P:(DE-He78)02e29e2d540ff21d777f3a03ec9f5ade$$aDeutsches Krebsforschungszentrum$$b5$$kDKFZ
000275924 9101_ $$0I:(DE-588b)2036810-0$$6P:(DE-He78)440a3f62ea9ea5c63375308976fc4c44$$aDeutsches Krebsforschungszentrum$$b6$$kDKFZ
000275924 9101_ $$0I:(DE-588b)2036810-0$$6P:(DE-He78)102624aca75cfe987c05343d5fdcf2fe$$aDeutsches Krebsforschungszentrum$$b7$$kDKFZ
000275924 9131_ $$0G:(DE-HGF)POF4-315$$1G:(DE-HGF)POF4-310$$2G:(DE-HGF)POF4-300$$3G:(DE-HGF)POF4$$4G:(DE-HGF)POF$$aDE-HGF$$bGesundheit$$lKrebsforschung$$vBildgebung und Radioonkologie$$x0
000275924 9141_ $$y2023
000275924 915__ $$0StatID:(DE-HGF)3001$$2StatID$$aDEAL Wiley$$d2022-11-12$$wger
000275924 915__ $$0StatID:(DE-HGF)0113$$2StatID$$aWoS$$bScience Citation Index Expanded$$d2022-11-12
000275924 915__ $$0StatID:(DE-HGF)0160$$2StatID$$aDBCoverage$$bEssential Science Indicators$$d2022-11-12
000275924 915__ $$0StatID:(DE-HGF)0100$$2StatID$$aJCR$$bMED PHYS : 2022$$d2023-10-21
000275924 915__ $$0StatID:(DE-HGF)0200$$2StatID$$aDBCoverage$$bSCOPUS$$d2023-10-21
000275924 915__ $$0StatID:(DE-HGF)0300$$2StatID$$aDBCoverage$$bMedline$$d2023-10-21
000275924 915__ $$0StatID:(DE-HGF)0320$$2StatID$$aDBCoverage$$bPubMed Central$$d2023-10-21
000275924 915__ $$0StatID:(DE-HGF)0600$$2StatID$$aDBCoverage$$bEbsco Academic Search$$d2023-10-21
000275924 915__ $$0StatID:(DE-HGF)0030$$2StatID$$aPeer Review$$bASC$$d2023-10-21
000275924 915__ $$0StatID:(DE-HGF)0199$$2StatID$$aDBCoverage$$bClarivate Analytics Master Journal List$$d2023-10-21
000275924 915__ $$0StatID:(DE-HGF)0150$$2StatID$$aDBCoverage$$bWeb of Science Core Collection$$d2023-10-21
000275924 915__ $$0StatID:(DE-HGF)1030$$2StatID$$aDBCoverage$$bCurrent Contents - Life Sciences$$d2023-10-21
000275924 915__ $$0StatID:(DE-HGF)1110$$2StatID$$aDBCoverage$$bCurrent Contents - Clinical Medicine$$d2023-10-21
000275924 915__ $$0StatID:(DE-HGF)9900$$2StatID$$aIF < 5$$d2023-10-21
000275924 9202_ $$0I:(DE-He78)E040-20160331$$kE040$$lE040 Med. Physik in der Strahlentherapie$$x0
000275924 9202_ $$0I:(DE-He78)E041-20160331$$kE041$$lE041 Med. Physik in der Radioonkologie$$x1
000275924 9201_ $$0I:(DE-He78)E040-20160331$$kE040$$lE040 Med. Physik in der Strahlentherapie$$x0
000275924 9201_ $$0I:(DE-He78)E041-20160331$$kE041$$lE041 Med. Physik in der Radioonkologie$$x1
000275924 9200_ $$0I:(DE-He78)E040-20160331$$kE040$$lE040 Med. Physik in der Strahlentherapie$$x0
000275924 980__ $$ajournal
000275924 980__ $$aVDB
000275924 980__ $$aI:(DE-He78)E040-20160331
000275924 980__ $$aI:(DE-He78)E041-20160331
000275924 980__ $$aUNRESTRICTED