Home > Publications database > Tailored and universal parallel transmit broadband pulses for homogeneous 3D excitation of the human heart at 7T. > print |
001 | 288813 | ||
005 | 20250729134052.0 | ||
024 | 7 | _ | |a 10.1002/mrm.30072 |2 doi |
024 | 7 | _ | |a pmid:38440957 |2 pmid |
024 | 7 | _ | |a 1522-2594 |2 ISSN |
024 | 7 | _ | |a 0740-3194 |2 ISSN |
037 | _ | _ | |a DKFZ-2024-00484 |
041 | _ | _ | |a English |
082 | _ | _ | |a 610 |
100 | 1 | _ | |a Aigner, Christoph Stefan |0 0000-0003-3618-9610 |b 0 |
245 | _ | _ | |a Tailored and universal parallel transmit broadband pulses for homogeneous 3D excitation of the human heart at 7T. |
260 | _ | _ | |a New York, NY [u.a.] |c 2024 |b Wiley-Liss |
336 | 7 | _ | |a article |2 DRIVER |
336 | 7 | _ | |a Output Types/Journal article |2 DataCite |
336 | 7 | _ | |a Journal Article |b journal |m journal |0 PUB:(DE-HGF)16 |s 1717405207_4830 |2 PUB:(DE-HGF) |
336 | 7 | _ | |a ARTICLE |2 BibTeX |
336 | 7 | _ | |a JOURNAL_ARTICLE |2 ORCID |
336 | 7 | _ | |a Journal Article |0 0 |2 EndNote |
500 | _ | _ | |a #LA:E020# / 2024 Aug;92(2):730-740 |
520 | _ | _ | |a To research and evaluate the performance of broadband tailored kT-point pulses (TP) and universal pulses (UP) for homogeneous excitation of the human heart at 7T.Relative 3D B 1 + $$ {\mathrm{B}}_1^{+} $$ -maps of the thorax were acquired from 29 healthy volunteers. TP and UP were designed using the small-tip-angle approximation for a different composition of up to seven resonance frequencies. TP were computed for each of the 29 B 1 + $$ {\mathrm{B}}_1^{+} $$ -maps, and UPs were calculated using 22 B 1 + $$ {\mathrm{B}}_1^{+} $$ -maps and tested in seven testcases. The performance of the pulses was analyzed using the coefficient of variation (CV) in the 3D heart volumes. The 3D gradient-echo (GRE) scans were acquired for the seven testcases to qualitatively validate the B 1 + $$ {\mathrm{B}}_1^{+} $$ -predictions.Single- and double-frequency optimized pulses achieved homogeneity in flip angle (FA) for the frequencies they were optimized for, while the broadband pulses achieved uniformity in FA across a 1300 Hz frequency range.Broadband TP and UP can be used for homogeneous excitation of the heart volume across a 1300 Hz frequency range, including the water and the main six fat peaks, or with longer pulse durations and higher FAs for a smaller transmit bandwidth. Moreover, despite large inter-volunteer variations, broadband UP can be used for calibration-free 3D heart FA homogenization in time-critical situations. |
536 | _ | _ | |a 315 - Bildgebung und Radioonkologie (POF4-315) |0 G:(DE-HGF)POF4-315 |c POF4-315 |f POF IV |x 0 |
588 | _ | _ | |a Dataset connected to CrossRef, PubMed, , Journals: inrepo02.dkfz.de |
650 | _ | 7 | |a 7 Tesla |2 Other |
650 | _ | 7 | |a body MRI |2 Other |
650 | _ | 7 | |a broadband |2 Other |
650 | _ | 7 | |a parallel transmission |2 Other |
650 | _ | 7 | |a universal pulse |2 Other |
700 | 1 | _ | |a Dietrich-Conzelmann, Sebastian |0 0000-0002-1610-909X |b 1 |
700 | 1 | _ | |a Lutz, Max |0 0009-0001-1956-3757 |b 2 |
700 | 1 | _ | |a Krüger, Felix |0 0000-0001-9453-8992 |b 3 |
700 | 1 | _ | |a Schmitter, Sebastian |0 P:(DE-He78)19e2d877276b0e5eec11cdfc1789a55e |b 4 |e Last author |u dkfz |
773 | _ | _ | |a 10.1002/mrm.30072 |g p. mrm.30072 |0 PERI:(DE-600)1493786-4 |n 2 |p 730-740 |t Magnetic resonance in medicine |v 92 |y 2024 |x 1522-2594 |
856 | 4 | _ | |u https://inrepo02.dkfz.de/record/288813/files/Magnetic%20Resonance%20in%20Med%20-%202024%20-%20Aigner%20-%20Tailored%20and%20universal%20parallel%20transmit%20broadband%20pulses%20for%20homogeneous%203D.pdf |
856 | 4 | _ | |u https://inrepo02.dkfz.de/record/288813/files/Magnetic%20Resonance%20in%20Med%20-%202024%20-%20Aigner%20-%20Tailored%20and%20universal%20parallel%20transmit%20broadband%20pulses%20for%20homogeneous%203D.pdf?subformat=pdfa |x pdfa |
909 | C | O | |p VDB |o oai:inrepo02.dkfz.de:288813 |
910 | 1 | _ | |a Deutsches Krebsforschungszentrum |0 I:(DE-588b)2036810-0 |k DKFZ |b 4 |6 P:(DE-He78)19e2d877276b0e5eec11cdfc1789a55e |
913 | 1 | _ | |a DE-HGF |b Gesundheit |l Krebsforschung |1 G:(DE-HGF)POF4-310 |0 G:(DE-HGF)POF4-315 |3 G:(DE-HGF)POF4 |2 G:(DE-HGF)POF4-300 |4 G:(DE-HGF)POF |v Bildgebung und Radioonkologie |x 0 |
914 | 1 | _ | |y 2024 |
915 | _ | _ | |a Nationallizenz |0 StatID:(DE-HGF)0420 |2 StatID |d 2023-10-21 |w ger |
915 | _ | _ | |a DEAL Wiley |0 StatID:(DE-HGF)3001 |2 StatID |d 2023-10-21 |w ger |
915 | _ | _ | |a JCR |0 StatID:(DE-HGF)0100 |2 StatID |b MAGN RESON MED : 2022 |d 2023-10-21 |
915 | _ | _ | |a DBCoverage |0 StatID:(DE-HGF)0200 |2 StatID |b SCOPUS |d 2023-10-21 |
915 | _ | _ | |a DBCoverage |0 StatID:(DE-HGF)0300 |2 StatID |b Medline |d 2023-10-21 |
915 | _ | _ | |a DBCoverage |0 StatID:(DE-HGF)0199 |2 StatID |b Clarivate Analytics Master Journal List |d 2023-10-21 |
915 | _ | _ | |a DBCoverage |0 StatID:(DE-HGF)1050 |2 StatID |b BIOSIS Previews |d 2023-10-21 |
915 | _ | _ | |a WoS |0 StatID:(DE-HGF)0113 |2 StatID |b Science Citation Index Expanded |d 2023-10-21 |
915 | _ | _ | |a DBCoverage |0 StatID:(DE-HGF)0150 |2 StatID |b Web of Science Core Collection |d 2023-10-21 |
915 | _ | _ | |a DBCoverage |0 StatID:(DE-HGF)1030 |2 StatID |b Current Contents - Life Sciences |d 2023-10-21 |
915 | _ | _ | |a DBCoverage |0 StatID:(DE-HGF)1190 |2 StatID |b Biological Abstracts |d 2023-10-21 |
915 | _ | _ | |a DBCoverage |0 StatID:(DE-HGF)0160 |2 StatID |b Essential Science Indicators |d 2023-10-21 |
915 | _ | _ | |a DBCoverage |0 StatID:(DE-HGF)1110 |2 StatID |b Current Contents - Clinical Medicine |d 2023-10-21 |
915 | _ | _ | |a IF < 5 |0 StatID:(DE-HGF)9900 |2 StatID |d 2023-10-21 |
920 | 2 | _ | |0 I:(DE-He78)E020-20160331 |k E020 |l E020 Med. Physik in der Radiologie |x 0 |
920 | 1 | _ | |0 I:(DE-He78)E020-20160331 |k E020 |l E020 Med. Physik in der Radiologie |x 0 |
980 | _ | _ | |a journal |
980 | _ | _ | |a VDB |
980 | _ | _ | |a I:(DE-He78)E020-20160331 |
980 | _ | _ | |a UNRESTRICTED |
Library | Collection | CLSMajor | CLSMinor | Language | Author |
---|