000293575 245__ $$aLocal and whole-body SAR in UHF body imaging: Implications for SAR matrix compression.
000293575 260__ $$aNew York, NY [u.a.]$$bWiley-Liss$$c2025
000293575 3367_ $$2DRIVER$$aarticle
000293575 3367_ $$2DataCite$$aOutput Types/Journal article
000293575 3367_ $$0PUB:(DE-HGF)16$$2PUB:(DE-HGF)$$aJournal Article$$bjournal$$mjournal$$s1733131268_26812
000293575 3367_ $$2BibTeX$$aARTICLE
000293575 3367_ $$2ORCID$$aJOURNAL_ARTICLE
000293575 3367_ $$00$$2EndNote$$aJournal Article
000293575 500__ $$a#EA:E020#LA:E020# / 2025 Feb;93(2):842-849
000293575 520__ $$aTransmit arrays for body imaging have characteristics of both volume and local transmit coils. This study evaluates two specific absorption rate (SAR) aspects, local and whole-body SAR, of arrays for body imaging at 7 T and also for a 3 T birdcage.Simulations were performed for six antenna arrays at 7 T and one 3 T birdcage. Local SAR matrices and the whole-body SAR matrix were computed and evaluated with random shims. A set of reduced local SAR matrices was determined by removing all matrices dominated by the whole-body SAR matrix.The results indicate that all RF transmit coils for body imaging in this study are constrained by the local SAR limit. The ratio between local and whole-body SAR is nevertheless smaller for arrays with large FOV, as these arrays also expose a larger part of the human body. By using the whole-body SAR matrix, the number of local SAR matrices can be reduced (e.g., 33.3% matrices remained for an 8-channel local array and 89.7% for a 30-channel remote array; 12.1% for the 3 T birdcage).For transmit antenna arrays used for body imaging at 7 T as well as for the 3 T birdcage, all evaluated cases show that the local SAR limit was reached before reaching the whole-body SAR limit. Nevertheless, the whole-body SAR matrix can be used to reduce the number of local SAR matrices, which is important to reduce memory and computing time for a virtual observation points (VOP) compression. This step can be included as a pre-compression prior to a VOP compression.
000293575 536__ $$0G:(DE-HGF)POF4-315$$a315 - Bildgebung und Radioonkologie (POF4-315)$$cPOF4-315$$fPOF IV$$x0
000293575 588__ $$aDataset connected to CrossRef, PubMed, , Journals: inrepo02.dkfz.de
000293575 650_7 $$2Other$$aUHF body imaging
000293575 650_7 $$2Other$$aVOPs
000293575 650_7 $$2Other$$alocal SAR
000293575 650_7 $$2Other$$awhole‐body SAR
000293575 7001_ $$0P:(DE-He78)022611a2317e4de40fd912e0a72293a8$$aLadd, Mark E$$b1$$udkfz
000293575 7001_ $$0P:(DE-He78)7985b432d853ab8929db0f1cb121667f$$aOrzada, Stephan$$b2$$eLast author$$udkfz
000293575 773__ $$0PERI:(DE-600)1493786-4$$a10.1002/mrm.30306$$gp. mrm.30306$$n2$$p842-849$$tMagnetic resonance in medicine$$v93$$x1522-2594$$y2025
000293575 8564_ $$uhttps://inrepo02.dkfz.de/record/293575/files/Magnetic%20Resonance%20in%20Med%20-%202024%20-%20Fiedler%20-%20Local%20and%20whole%E2%80%90body%20SAR%20in%20UHF%20body%20imaging%20Implications%20for%20SAR%20matrix.pdf
000293575 8564_ $$uhttps://inrepo02.dkfz.de/record/293575/files/Magnetic%20Resonance%20in%20Med%20-%202024%20-%20Fiedler%20-%20Local%20and%20whole%E2%80%90body%20SAR%20in%20UHF%20body%20imaging%20Implications%20for%20SAR%20matrix.pdf?subformat=pdfa$$xpdfa
000293575 909CO $$ooai:inrepo02.dkfz.de:293575$$pVDB
000293575 9101_ $$0I:(DE-588b)2036810-0$$6P:(DE-He78)bcbe9862276365dd99a98b48449fd046$$aDeutsches Krebsforschungszentrum$$b0$$kDKFZ
000293575 9101_ $$0I:(DE-588b)2036810-0$$6P:(DE-He78)022611a2317e4de40fd912e0a72293a8$$aDeutsches Krebsforschungszentrum$$b1$$kDKFZ
000293575 9101_ $$0I:(DE-588b)2036810-0$$6P:(DE-He78)7985b432d853ab8929db0f1cb121667f$$aDeutsches Krebsforschungszentrum$$b2$$kDKFZ
000293575 9131_ $$0G:(DE-HGF)POF4-315$$1G:(DE-HGF)POF4-310$$2G:(DE-HGF)POF4-300$$3G:(DE-HGF)POF4$$4G:(DE-HGF)POF$$aDE-HGF$$bGesundheit$$lKrebsforschung$$vBildgebung und Radioonkologie$$x0
000293575 9141_ $$y2024
000293575 915__ $$0StatID:(DE-HGF)0420$$2StatID$$aNationallizenz$$d2023-10-21$$wger
000293575 915__ $$0StatID:(DE-HGF)3001$$2StatID$$aDEAL Wiley$$d2023-10-21$$wger
000293575 915__ $$0StatID:(DE-HGF)0100$$2StatID$$aJCR$$bMAGN RESON MED : 2022$$d2023-10-21
000293575 915__ $$0StatID:(DE-HGF)0200$$2StatID$$aDBCoverage$$bSCOPUS$$d2023-10-21
000293575 915__ $$0StatID:(DE-HGF)0300$$2StatID$$aDBCoverage$$bMedline$$d2023-10-21
000293575 915__ $$0StatID:(DE-HGF)0199$$2StatID$$aDBCoverage$$bClarivate Analytics Master Journal List$$d2023-10-21
000293575 915__ $$0StatID:(DE-HGF)1050$$2StatID$$aDBCoverage$$bBIOSIS Previews$$d2023-10-21
000293575 915__ $$0StatID:(DE-HGF)0113$$2StatID$$aWoS$$bScience Citation Index Expanded$$d2023-10-21
000293575 915__ $$0StatID:(DE-HGF)0150$$2StatID$$aDBCoverage$$bWeb of Science Core Collection$$d2023-10-21
000293575 915__ $$0StatID:(DE-HGF)1030$$2StatID$$aDBCoverage$$bCurrent Contents - Life Sciences$$d2023-10-21
000293575 915__ $$0StatID:(DE-HGF)1190$$2StatID$$aDBCoverage$$bBiological Abstracts$$d2023-10-21
000293575 915__ $$0StatID:(DE-HGF)0160$$2StatID$$aDBCoverage$$bEssential Science Indicators$$d2023-10-21
000293575 915__ $$0StatID:(DE-HGF)1110$$2StatID$$aDBCoverage$$bCurrent Contents - Clinical Medicine$$d2023-10-21
000293575 915__ $$0StatID:(DE-HGF)9900$$2StatID$$aIF < 5$$d2023-10-21
000293575 9202_ $$0I:(DE-He78)E020-20160331$$kE020$$lE020 Med. Physik in der Radiologie$$x0
000293575 9201_ $$0I:(DE-He78)E020-20160331$$kE020$$lE020 Med. Physik in der Radiologie$$x0
000293575 9200_ $$0I:(DE-He78)E020-20160331$$kE020$$lE020 Med. Physik in der Radiologie$$x0
000293575 980__ $$ajournal
000293575 980__ $$aVDB
000293575 980__ $$aI:(DE-He78)E020-20160331
000293575 980__ $$aUNRESTRICTED