000299842 245__ $$aInterleaved 23Na/1H MRI of the human heart at 7 T using a combined 23Na/1H coil setup and 1H parallel transmission.
000299842 260__ $$aNew York, NY [u.a.]$$bWiley-Liss$$c2025
000299842 3367_ $$2DRIVER$$aarticle
000299842 3367_ $$2DataCite$$aOutput Types/Journal article
000299842 3367_ $$0PUB:(DE-HGF)16$$2PUB:(DE-HGF)$$aJournal Article$$bjournal$$mjournal$$s1745573472_23537
000299842 3367_ $$2BibTeX$$aARTICLE
000299842 3367_ $$2ORCID$$aJOURNAL_ARTICLE
000299842 3367_ $$00$$2EndNote$$aJournal Article
000299842 500__ $$a#LA:E020# / Volume 94, Issue 1, July 2025, Pages 231-241
000299842 520__ $$aTo evaluate the feasibility of interleaved 23Na/1H cardiac MRI at 7 T using 1H parallel transmission (pTx) pulses.A combined setup consisting of a 23Na volume coil and two 1H transceiver arrays was employed and the transmit and receive characteristics were compared in vitro with those of the uncombined radiofrequency coils. Furthermore, the implemented interleaved 23Na/1H pTx sequence was validated in phantom measurements and applied to four healthy subjects. For the latter, three customized 1H excitation pulses (universal and individual phase shims (UPS/IPS) and individual 4kT pulses (4kT)) were employed in the interleaved 23Na/1H pTx sequence and compared with the vendor-provided default cardiac phase shim (DPS).Combining both coils resulted in a reduction of the mean 23Na transmit field (B1 +) efficiency and 23Na signal-to-noise ratio by 18.9% and 15.4% for the combined setup, whereas the 1H B1 + efficiency was less influenced (-4.7%). Compared with single-nuclear acquisitions, interleaved dual-nuclear 23Na/1H MRI showed negligible influence on 23Na and 1H image quality. For all three customized 1H pTx pulses the B1 + homogeneity was improved (coefficients of variation: CVUPS = 0.30, CVIPS = 0.23, CV4kT = 0.15) and no 1H signal dropouts occurred compared with the vendor-provided default phase shim (CVDPS = 0.37).The incorporation of customized 1H pTx pulses in an interleaved 23Na/1H sequence scheme was successfully demonstrated at 7 T and improvements of the 1H B1 + homogeneity within the heart were shown. Combining interleaved 23Na/1H MRI with 1H pTx is an important tool to enable robust quantification of myocardial tissue sodium concentrations at 7 T within clinically acceptable acquisition times.
000299842 536__ $$0G:(DE-HGF)POF4-315$$a315 - Bildgebung und Radioonkologie (POF4-315)$$cPOF4-315$$fPOF IV$$x0
000299842 588__ $$aDataset connected to CrossRef, PubMed, , Journals: inrepo02.dkfz.de
000299842 650_7 $$2Other$$a23Na RF birdcage coil
000299842 650_7 $$2Other$$a7 Tesla
000299842 650_7 $$2Other$$acardiac sodium (23Na) MRI
000299842 650_7 $$2Other$$ainterleaved acquisition
000299842 650_7 $$2Other$$aparallel transmission (pTx)
000299842 7001_ $$00000-0002-7092-1847$$aEgger, Nico$$b1
000299842 7001_ $$00000-0002-2520-9025$$aWilferth, Tobias$$b2
000299842 7001_ $$aSchirmer, Judith$$b3
000299842 7001_ $$00000-0002-4599-1122$$aGast, Lena Vanessa$$b4
000299842 7001_ $$aNagelstraßer, Sophia$$b5
000299842 7001_ $$aWildenberg, Saskia$$b6
000299842 7001_ $$aBitz, Andreas$$b7
000299842 7001_ $$aLanz, Titus$$b8
000299842 7001_ $$0P:(DE-He78)3c42114fa37390cfdc976bf0a9fcfb67$$aPlatt, Tanja$$b9$$udkfz
000299842 7001_ $$00000-0002-8143-2221$$aKonstandin, Simon$$b10
000299842 7001_ $$aKopp, Christoph$$b11
000299842 7001_ $$aUder, Michael$$b12
000299842 7001_ $$0P:(DE-He78)054fd7a5195b75b11fbdc5c360276011$$aNagel, Armin$$b13$$eLast author$$udkfz
000299842 773__ $$0PERI:(DE-600)1493786-4$$a10.1002/mrm.30426$$gp. mrm.30426$$n1$$p231-241$$tMagnetic resonance in medicine$$v94$$x1522-2594$$y2025
000299842 909CO $$ooai:inrepo02.dkfz.de:299842$$pVDB
000299842 9101_ $$0I:(DE-588b)2036810-0$$6P:(DE-He78)3c42114fa37390cfdc976bf0a9fcfb67$$aDeutsches Krebsforschungszentrum$$b9$$kDKFZ
000299842 9101_ $$0I:(DE-588b)2036810-0$$6P:(DE-He78)054fd7a5195b75b11fbdc5c360276011$$aDeutsches Krebsforschungszentrum$$b13$$kDKFZ
000299842 9131_ $$0G:(DE-HGF)POF4-315$$1G:(DE-HGF)POF4-310$$2G:(DE-HGF)POF4-300$$3G:(DE-HGF)POF4$$4G:(DE-HGF)POF$$aDE-HGF$$bGesundheit$$lKrebsforschung$$vBildgebung und Radioonkologie$$x0
000299842 9141_ $$y2025
000299842 915__ $$0StatID:(DE-HGF)0420$$2StatID$$aNationallizenz$$d2025-01-02$$wger
000299842 915__ $$0StatID:(DE-HGF)3001$$2StatID$$aDEAL Wiley$$d2025-01-02$$wger
000299842 915__ $$0StatID:(DE-HGF)0200$$2StatID$$aDBCoverage$$bSCOPUS$$d2025-01-02
000299842 915__ $$0StatID:(DE-HGF)0300$$2StatID$$aDBCoverage$$bMedline$$d2025-01-02
000299842 915__ $$0StatID:(DE-HGF)0199$$2StatID$$aDBCoverage$$bClarivate Analytics Master Journal List$$d2025-01-02
000299842 915__ $$0StatID:(DE-HGF)1050$$2StatID$$aDBCoverage$$bBIOSIS Previews$$d2025-01-02
000299842 915__ $$0StatID:(DE-HGF)0160$$2StatID$$aDBCoverage$$bEssential Science Indicators$$d2025-01-02
000299842 915__ $$0StatID:(DE-HGF)1030$$2StatID$$aDBCoverage$$bCurrent Contents - Life Sciences$$d2025-01-02
000299842 915__ $$0StatID:(DE-HGF)1190$$2StatID$$aDBCoverage$$bBiological Abstracts$$d2025-01-02
000299842 915__ $$0StatID:(DE-HGF)1110$$2StatID$$aDBCoverage$$bCurrent Contents - Clinical Medicine$$d2025-01-02
000299842 915__ $$0StatID:(DE-HGF)0113$$2StatID$$aWoS$$bScience Citation Index Expanded$$d2025-01-02
000299842 915__ $$0StatID:(DE-HGF)0150$$2StatID$$aDBCoverage$$bWeb of Science Core Collection$$d2025-01-02
000299842 9202_ $$0I:(DE-He78)E020-20160331$$kE020$$lE020 Med. Physik in der Radiologie$$x0
000299842 9201_ $$0I:(DE-He78)E020-20160331$$kE020$$lE020 Med. Physik in der Radiologie$$x0
000299842 980__ $$ajournal
000299842 980__ $$aVDB
000299842 980__ $$aI:(DE-He78)E020-20160331
000299842 980__ $$aUNRESTRICTED