001     299842
005     20250425113203.0
024 7 _ |a 10.1002/mrm.30426
|2 doi
024 7 _ |a pmid:40065602
|2 pmid
024 7 _ |a 1522-2594
|2 ISSN
024 7 _ |a 0740-3194
|2 ISSN
037 _ _ |a DKFZ-2025-00579
041 _ _ |a English
082 _ _ |a 610
100 1 _ |a Ruck, Laurent
|0 0000-0002-5978-3383
|b 0
245 _ _ |a Interleaved 23Na/1H MRI of the human heart at 7 T using a combined 23Na/1H coil setup and 1H parallel transmission.
260 _ _ |a New York, NY [u.a.]
|c 2025
|b Wiley-Liss
336 7 _ |a article
|2 DRIVER
336 7 _ |a Output Types/Journal article
|2 DataCite
336 7 _ |a Journal Article
|b journal
|m journal
|0 PUB:(DE-HGF)16
|s 1745573472_23537
|2 PUB:(DE-HGF)
336 7 _ |a ARTICLE
|2 BibTeX
336 7 _ |a JOURNAL_ARTICLE
|2 ORCID
336 7 _ |a Journal Article
|0 0
|2 EndNote
500 _ _ |a #LA:E020# / Volume 94, Issue 1, July 2025, Pages 231-241
520 _ _ |a To evaluate the feasibility of interleaved 23Na/1H cardiac MRI at 7 T using 1H parallel transmission (pTx) pulses.A combined setup consisting of a 23Na volume coil and two 1H transceiver arrays was employed and the transmit and receive characteristics were compared in vitro with those of the uncombined radiofrequency coils. Furthermore, the implemented interleaved 23Na/1H pTx sequence was validated in phantom measurements and applied to four healthy subjects. For the latter, three customized 1H excitation pulses (universal and individual phase shims (UPS/IPS) and individual 4kT pulses (4kT)) were employed in the interleaved 23Na/1H pTx sequence and compared with the vendor-provided default cardiac phase shim (DPS).Combining both coils resulted in a reduction of the mean 23Na transmit field (B1 +) efficiency and 23Na signal-to-noise ratio by 18.9% and 15.4% for the combined setup, whereas the 1H B1 + efficiency was less influenced (-4.7%). Compared with single-nuclear acquisitions, interleaved dual-nuclear 23Na/1H MRI showed negligible influence on 23Na and 1H image quality. For all three customized 1H pTx pulses the B1 + homogeneity was improved (coefficients of variation: CVUPS = 0.30, CVIPS = 0.23, CV4kT = 0.15) and no 1H signal dropouts occurred compared with the vendor-provided default phase shim (CVDPS = 0.37).The incorporation of customized 1H pTx pulses in an interleaved 23Na/1H sequence scheme was successfully demonstrated at 7 T and improvements of the 1H B1 + homogeneity within the heart were shown. Combining interleaved 23Na/1H MRI with 1H pTx is an important tool to enable robust quantification of myocardial tissue sodium concentrations at 7 T within clinically acceptable acquisition times.
536 _ _ |a 315 - Bildgebung und Radioonkologie (POF4-315)
|0 G:(DE-HGF)POF4-315
|c POF4-315
|f POF IV
|x 0
588 _ _ |a Dataset connected to CrossRef, PubMed, , Journals: inrepo02.dkfz.de
650 _ 7 |a 23Na RF birdcage coil
|2 Other
650 _ 7 |a 7 Tesla
|2 Other
650 _ 7 |a cardiac sodium (23Na) MRI
|2 Other
650 _ 7 |a interleaved acquisition
|2 Other
650 _ 7 |a parallel transmission (pTx)
|2 Other
700 1 _ |a Egger, Nico
|0 0000-0002-7092-1847
|b 1
700 1 _ |a Wilferth, Tobias
|0 0000-0002-2520-9025
|b 2
700 1 _ |a Schirmer, Judith
|b 3
700 1 _ |a Gast, Lena Vanessa
|0 0000-0002-4599-1122
|b 4
700 1 _ |a Nagelstraßer, Sophia
|b 5
700 1 _ |a Wildenberg, Saskia
|b 6
700 1 _ |a Bitz, Andreas
|b 7
700 1 _ |a Lanz, Titus
|b 8
700 1 _ |a Platt, Tanja
|0 P:(DE-He78)3c42114fa37390cfdc976bf0a9fcfb67
|b 9
|u dkfz
700 1 _ |a Konstandin, Simon
|0 0000-0002-8143-2221
|b 10
700 1 _ |a Kopp, Christoph
|b 11
700 1 _ |a Uder, Michael
|b 12
700 1 _ |a Nagel, Armin
|0 P:(DE-He78)054fd7a5195b75b11fbdc5c360276011
|b 13
|e Last author
|u dkfz
773 _ _ |a 10.1002/mrm.30426
|g p. mrm.30426
|0 PERI:(DE-600)1493786-4
|n 1
|p 231-241
|t Magnetic resonance in medicine
|v 94
|y 2025
|x 1522-2594
909 C O |p VDB
|o oai:inrepo02.dkfz.de:299842
910 1 _ |a Deutsches Krebsforschungszentrum
|0 I:(DE-588b)2036810-0
|k DKFZ
|b 9
|6 P:(DE-He78)3c42114fa37390cfdc976bf0a9fcfb67
910 1 _ |a Deutsches Krebsforschungszentrum
|0 I:(DE-588b)2036810-0
|k DKFZ
|b 13
|6 P:(DE-He78)054fd7a5195b75b11fbdc5c360276011
913 1 _ |a DE-HGF
|b Gesundheit
|l Krebsforschung
|1 G:(DE-HGF)POF4-310
|0 G:(DE-HGF)POF4-315
|3 G:(DE-HGF)POF4
|2 G:(DE-HGF)POF4-300
|4 G:(DE-HGF)POF
|v Bildgebung und Radioonkologie
|x 0
914 1 _ |y 2025
915 _ _ |a Nationallizenz
|0 StatID:(DE-HGF)0420
|2 StatID
|d 2025-01-02
|w ger
915 _ _ |a DEAL Wiley
|0 StatID:(DE-HGF)3001
|2 StatID
|d 2025-01-02
|w ger
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0200
|2 StatID
|b SCOPUS
|d 2025-01-02
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0300
|2 StatID
|b Medline
|d 2025-01-02
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0199
|2 StatID
|b Clarivate Analytics Master Journal List
|d 2025-01-02
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)1050
|2 StatID
|b BIOSIS Previews
|d 2025-01-02
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0160
|2 StatID
|b Essential Science Indicators
|d 2025-01-02
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)1030
|2 StatID
|b Current Contents - Life Sciences
|d 2025-01-02
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)1190
|2 StatID
|b Biological Abstracts
|d 2025-01-02
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)1110
|2 StatID
|b Current Contents - Clinical Medicine
|d 2025-01-02
915 _ _ |a WoS
|0 StatID:(DE-HGF)0113
|2 StatID
|b Science Citation Index Expanded
|d 2025-01-02
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0150
|2 StatID
|b Web of Science Core Collection
|d 2025-01-02
920 2 _ |0 I:(DE-He78)E020-20160331
|k E020
|l E020 Med. Physik in der Radiologie
|x 0
920 1 _ |0 I:(DE-He78)E020-20160331
|k E020
|l E020 Med. Physik in der Radiologie
|x 0
980 _ _ |a journal
980 _ _ |a VDB
980 _ _ |a I:(DE-He78)E020-20160331
980 _ _ |a UNRESTRICTED


LibraryCollectionCLSMajorCLSMinorLanguageAuthor
Marc 21