001     302139
005     20250625113753.0
024 7 _ |a 10.1002/nbm.70080
|2 doi
024 7 _ |a pmid:40533359
|2 pmid
024 7 _ |a pmc:PMC12176530
|2 pmc
024 7 _ |a 0952-3480
|2 ISSN
024 7 _ |a 1099-1492
|2 ISSN
037 _ _ |a DKFZ-2025-01257
041 _ _ |a English
082 _ _ |a 610
100 1 _ |a Lutz, Max
|0 0009-0001-1956-3757
|b 0
245 _ _ |a Accurate MRF-Based 3D Multi-Channel B1 + Mapping in the Human Body at 7 T.
260 _ _ |a New York, NY
|c 2025
|b Wiley
336 7 _ |a article
|2 DRIVER
336 7 _ |a Output Types/Journal article
|2 DataCite
336 7 _ |a Journal Article
|b journal
|m journal
|0 PUB:(DE-HGF)16
|s 1750760481_16805
|2 PUB:(DE-HGF)
336 7 _ |a ARTICLE
|2 BibTeX
336 7 _ |a JOURNAL_ARTICLE
|2 ORCID
336 7 _ |a Journal Article
|0 0
|2 EndNote
500 _ _ |a #LA:E020#
520 _ _ |a This work proposes a 3D multi-transmit channel B1 + mapping approach based on magnetic resonance fingerprinting (MRF) for the human abdomen at 7 T. A stack-of-stars acquisition is employed to achieve motion-robust 3D encoding, along with a hybrid method where transmit (Tx) channel-wise B1 + information is obtained through low flip angle GRE images. B1 + mapping at ultra-high field (UHF) in the human abdomen is particularly challenging due to the large dynamic range of B1 +, the extensive field of view (FOV), and the effects of respiratory motion. Few methods have been proposed to address these challenges, with a significant limitation being the relatively low RF power available at UHF, especially for pTx systems with a 8 × 1 kW power configuration. This limitation makes it difficult to achieve FAs greater than 30° in central body regions, which are required for accurate results with classical methods. In contrast, Tx channel-combined MRF-based B1 + mapping has been validated as accurate for FAs greater than 6°, offering improved accuracy at low FAs. Here, two Tx channel-combined MRF-based B1 + maps (B1-MRF) are acquired using two tailored complementary phase shims to obtain absolute B1 + information across the entire FOV. The 3D hybrid approach was validated against a 2D reference using phantoms and in vivo free-breathing scans in three subjects with varying BMIs, where only one Tx channel was active at a time. The comparison showed strong agreement, with the 3D hybrid acquisition demonstrating improved performance in regions affected by flow, low FAs, or low signal-to-noise ratio compared to the 2D implementation. The higher accuracy and level of detail provided by the proposed method, in contrast to existing methods, are particularly relevant for several applications, including the validation of faster approaches, validation of electromagnetic simulations (which are safety-critical), and the creation of B1 + map libraries for applications such as AI-based B1 + mapping or universal pulse calculations.
536 _ _ |a 315 - Bildgebung und Radioonkologie (POF4-315)
|0 G:(DE-HGF)POF4-315
|c POF4-315
|f POF IV
|x 0
588 _ _ |a Dataset connected to CrossRef, PubMed, , Journals: inrepo02.dkfz.de
650 _ 7 |a 7 Tesla
|2 Other
650 _ 7 |a B1+ mapping
|2 Other
650 _ 7 |a MRF
|2 Other
650 _ 7 |a body MRI
|2 Other
650 _ 7 |a ultrahigh field MRI
|2 Other
650 _ 2 |a Humans
|2 MeSH
650 _ 2 |a Imaging, Three-Dimensional
|2 MeSH
650 _ 2 |a Magnetic Resonance Imaging
|2 MeSH
650 _ 2 |a Phantoms, Imaging
|2 MeSH
650 _ 2 |a Adult
|2 MeSH
650 _ 2 |a Male
|2 MeSH
650 _ 2 |a Female
|2 MeSH
700 1 _ |a Flassbeck, Sebastian
|b 1
700 1 _ |a Aigner, Christoph Stefan
|0 0000-0003-3618-9610
|b 2
700 1 _ |a Krueger, Felix
|0 0000-0001-9453-8992
|b 3
700 1 _ |a Schaeffter, Tobias
|0 0000-0003-1310-2631
|b 4
700 1 _ |a Schmitter, Sebastian
|0 P:(DE-He78)19e2d877276b0e5eec11cdfc1789a55e
|b 5
|e Last author
|u dkfz
773 _ _ |a 10.1002/nbm.70080
|g Vol. 38, no. 8, p. e70080
|0 PERI:(DE-600)2002003-X
|n 8
|p e70080
|t NMR in biomedicine
|v 38
|y 2025
|x 0952-3480
909 C O |o oai:inrepo02.dkfz.de:302139
|p VDB
910 1 _ |a Deutsches Krebsforschungszentrum
|0 I:(DE-588b)2036810-0
|k DKFZ
|b 5
|6 P:(DE-He78)19e2d877276b0e5eec11cdfc1789a55e
913 1 _ |a DE-HGF
|b Gesundheit
|l Krebsforschung
|1 G:(DE-HGF)POF4-310
|0 G:(DE-HGF)POF4-315
|3 G:(DE-HGF)POF4
|2 G:(DE-HGF)POF4-300
|4 G:(DE-HGF)POF
|v Bildgebung und Radioonkologie
|x 0
914 1 _ |y 2025
915 _ _ |a Nationallizenz
|0 StatID:(DE-HGF)0420
|2 StatID
|d 2024-12-12
|w ger
915 _ _ |a DEAL Wiley
|0 StatID:(DE-HGF)3001
|2 StatID
|d 2024-12-12
|w ger
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0200
|2 StatID
|b SCOPUS
|d 2024-12-12
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0300
|2 StatID
|b Medline
|d 2024-12-12
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0199
|2 StatID
|b Clarivate Analytics Master Journal List
|d 2024-12-12
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0160
|2 StatID
|b Essential Science Indicators
|d 2024-12-12
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)1030
|2 StatID
|b Current Contents - Life Sciences
|d 2024-12-12
915 _ _ |a WoS
|0 StatID:(DE-HGF)0113
|2 StatID
|b Science Citation Index Expanded
|d 2024-12-12
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0150
|2 StatID
|b Web of Science Core Collection
|d 2024-12-12
915 _ _ |a JCR
|0 StatID:(DE-HGF)0100
|2 StatID
|b NMR BIOMED : 2022
|d 2024-12-12
915 _ _ |a IF < 5
|0 StatID:(DE-HGF)9900
|2 StatID
|d 2024-12-12
920 2 _ |0 I:(DE-He78)E020-20160331
|k E020
|l E020 Med. Physik in der Radiologie
|x 0
920 1 _ |0 I:(DE-He78)E020-20160331
|k E020
|l E020 Med. Physik in der Radiologie
|x 0
980 _ _ |a journal
980 _ _ |a VDB
980 _ _ |a I:(DE-He78)E020-20160331
980 _ _ |a UNRESTRICTED


LibraryCollectionCLSMajorCLSMinorLanguageAuthor
Marc 21