TI  - 2.5D imaging: obtaining depth information from 2D helium-beam radiographs.
JO  - Physics in medicine and biology
VL  - 70
IS  - 20
SN  - 0031-9155
CY  - Bristol
PB  - IOP Publ.
M1  - DKFZ-2025-02140
SP  - 205017
PY  - 2025
N1  - #EA:E040#LA:E040#
AB  - Objective.Ion-beam radiography has been proposed as a daily on-couch imaging modality for ion-beam radiotherapy range verification. However, an ion-beam radiograph only contains 2D information since it shows a projection of the patient along the beam direction. To extract depth information of anatomical changes from 2D helium-beam radiographs, we experimentally investigated the 2.5D imaging approach.Approach.At the Heidelberg ion-beam therapy center, we acquired helium-beam radiographs of a homogeneous plastic phantom and an anthropomorphic phantom. We changed the geometry of both phantoms to mimic anatomical changes and acquired data before and after the change. After reconstructing plane-of-interest difference images along depth in 1 mm steps, we analyzed the spatial resolution by means of the slanted edge approach and a method based on a median filter and Tenengrad focus measure. The depth of the maximum spatial resolution was then compared to the one where the change was introduced in the experiment and their difference was determined as measure of accuracy.Main results.For both the slanted edge and Tenengrad method, all accuracy values of the plastic phantom were below 11 mm. Furthermore, the found depth values of all but one gap position coincided with the ground truth position of the edge within the 2 σuncertainty. In the anthropomorphic phantom, we reached a depth accuracy of13-7+5 mm.Significance.The 2.5D imaging approach, which was investigated experimentally for the first time in this work, offers a technique to estimate the depth of an anatomical change based on the acquisition of 2D ion-beam radiographs. This information is crucial to determine whether the change is located within the treatment field and thus impairs the treatment. 2.5D ion-beam radiography could therefore be used for daily on-couch imaging to monitor the anatomy of the patient and make ion-beam radiotherapy treatments more precise.
KW  - Helium
KW  - Phantoms, Imaging
KW  - Humans
KW  - Image Processing, Computer-Assisted: methods
KW  - Radiography: methods
KW  - Timepix detectors (Other)
KW  - helium ions (Other)
KW  - ion-beam imaging (Other)
KW  - particle radiography (Other)
KW  - particle therapy (Other)
KW  - proton therapy (Other)
KW  - spatial resolution (Other)
KW  - Helium (NLM Chemicals)
LB  - PUB:(DE-HGF)16
C6  - pmid:40902647
DO  - DOI:10.1088/1361-6560/ae02de
UR  - https://inrepo02.dkfz.de/record/305403
ER  -