000305533 001__ 305533
000305533 005__ 20251230140634.0
000305533 0247_ $$2doi$$a10.1002/mrm.70139
000305533 0247_ $$2pmid$$apmid:41133303
000305533 0247_ $$2ISSN$$a1522-2594
000305533 0247_ $$2ISSN$$a0740-3194
000305533 037__ $$aDKFZ-2025-02207
000305533 041__ $$aEnglish
000305533 082__ $$a610
000305533 1001_ $$00009-0003-8221-0465$$aBarendsz, Laura J C$$b0
000305533 245__ $$aTicept: Wideband Electrical Properties Tomography by Tissue Composition Assessment With Quantitative $^{1}$H$^{23}$Na$^{39}$K Multinuclear MRI.
000305533 260__ $$aNew York, NY [u.a.]$$bWiley-Liss$$c2026
000305533 3367_ $$2DRIVER$$aarticle
000305533 3367_ $$2DataCite$$aOutput Types/Journal article
000305533 3367_ $$0PUB:(DE-HGF)16$$2PUB:(DE-HGF)$$aJournal Article$$bjournal$$mjournal$$s1767099951_1386403
000305533 3367_ $$2BibTeX$$aARTICLE
000305533 3367_ $$2ORCID$$aJOURNAL_ARTICLE
000305533 3367_ $$00$$2EndNote$$aJournal Article
000305533 500__ $$a2026 Mar;95(3):1503-1512. doi: 10.1002/mrm.70139. Epub 2025 Oct 24
000305533 520__ $$aTo develop a noninvasive method for estimating dielectric properties over a wide frequency range from 50 to 600 MHz. Existing methods are limited in accuracy and provide single-frequency results. Furthermore, accurate knowledge of dielectric properties becomes more important, since medical device design and safety evaluation increasingly rely on computational modeling-based evaluation.Tissue composition assessment was performed to find the most important factors for the dielectric properties, which were sodium, potassium, and water. These were measured with a 3D acquisition-weighted density-adapted stack-of-stars scheme ($^{23}$ Na and $^{39}$ K) and an inversion recovery turbo spin echo sequence ($^{1}$H). Measurements were conducted in muscle-representative phantoms and six healthy volunteers. These measurements were used as input for mixture models, which were used to correlate the dielectric properties of the mixture with its constituents. Four different mixture models were tested to assess the feasibility of this method.With the Maxwell-Garnett mixture model, a 7.9% error in the real relative permittivity and a 4.0% error in the effective conductivity are found for the phantoms. The in vivo values are in a similar range to those reported in literature.We presented the feasibility of estimating dielectric properties over a wide frequency band with quantitative MRI, leading to a new method: $^{1}$H$^{23}$Na$^{39}$K-TiCEPT. A discrepancy can be observed in the 50-200 MHz range, but the data aligns with literature from 200-600 MHz. These results show substantial intersubject differences in effective conductivity (29%), supporting the need for an accurate method to provide in vivo dielectric tissue properties.
000305533 536__ $$0G:(DE-HGF)POF4-315$$a315 - Bildgebung und Radioonkologie (POF4-315)$$cPOF4-315$$fPOF IV$$x0
000305533 588__ $$aDataset connected to CrossRef, PubMed, , Journals: inrepo02.dkfz.de
000305533 650_7 $$2Other$$aelectrical conductivity
000305533 650_7 $$2Other$$aelectrical properties tomography (EPT)
000305533 650_7 $$2Other$$amixture theory
000305533 650_7 $$2Other$$apermittivity
000305533 650_7 $$2Other$$apotassium MRI
000305533 650_7 $$2Other$$asodium MRI
000305533 650_7 $$2Other$$atissue water content
000305533 7001_ $$00000-0002-6695-2659$$aSumser, Kemal$$b1
000305533 7001_ $$00000-0001-9734-4632$$aGerhalter, Teresa$$b2
000305533 7001_ $$00000-0002-1971-8691$$aMestrom, Rob M C$$b3
000305533 7001_ $$0P:(DE-He78)054fd7a5195b75b11fbdc5c360276011$$aNagel, Armin$$b4$$udkfz
000305533 7001_ $$00000-0002-5891-2139$$aPaulides, Margarethus M$$b5
000305533 773__ $$0PERI:(DE-600)1493786-4$$a10.1002/mrm.70139$$gp. mrm.70139$$n3$$p1503-1512$$tMagnetic resonance in medicine$$v95$$x1522-2594$$y2026
000305533 909CO $$ooai:inrepo02.dkfz.de:305533$$pVDB
000305533 9101_ $$0I:(DE-588b)2036810-0$$6P:(DE-He78)054fd7a5195b75b11fbdc5c360276011$$aDeutsches Krebsforschungszentrum$$b4$$kDKFZ
000305533 9131_ $$0G:(DE-HGF)POF4-315$$1G:(DE-HGF)POF4-310$$2G:(DE-HGF)POF4-300$$3G:(DE-HGF)POF4$$4G:(DE-HGF)POF$$aDE-HGF$$bGesundheit$$lKrebsforschung$$vBildgebung und Radioonkologie$$x0
000305533 9141_ $$y2025
000305533 915__ $$0StatID:(DE-HGF)0420$$2StatID$$aNationallizenz$$d2025-01-02$$wger
000305533 915__ $$0StatID:(DE-HGF)3001$$2StatID$$aDEAL Wiley$$d2025-01-02$$wger
000305533 915__ $$0StatID:(DE-HGF)0200$$2StatID$$aDBCoverage$$bSCOPUS$$d2025-01-02
000305533 915__ $$0StatID:(DE-HGF)0300$$2StatID$$aDBCoverage$$bMedline$$d2025-01-02
000305533 915__ $$0StatID:(DE-HGF)0199$$2StatID$$aDBCoverage$$bClarivate Analytics Master Journal List$$d2025-01-02
000305533 915__ $$0StatID:(DE-HGF)1050$$2StatID$$aDBCoverage$$bBIOSIS Previews$$d2025-01-02
000305533 915__ $$0StatID:(DE-HGF)0160$$2StatID$$aDBCoverage$$bEssential Science Indicators$$d2025-01-02
000305533 915__ $$0StatID:(DE-HGF)1030$$2StatID$$aDBCoverage$$bCurrent Contents - Life Sciences$$d2025-01-02
000305533 915__ $$0StatID:(DE-HGF)1190$$2StatID$$aDBCoverage$$bBiological Abstracts$$d2025-01-02
000305533 915__ $$0StatID:(DE-HGF)1110$$2StatID$$aDBCoverage$$bCurrent Contents - Clinical Medicine$$d2025-01-02
000305533 915__ $$0StatID:(DE-HGF)0113$$2StatID$$aWoS$$bScience Citation Index Expanded$$d2025-01-02
000305533 915__ $$0StatID:(DE-HGF)0150$$2StatID$$aDBCoverage$$bWeb of Science Core Collection$$d2025-01-02
000305533 9201_ $$0I:(DE-He78)E020-20160331$$kE020$$lE020 Med. Physik in der Radiologie$$x0
000305533 980__ $$ajournal
000305533 980__ $$aVDB
000305533 980__ $$aI:(DE-He78)E020-20160331
000305533 980__ $$aUNRESTRICTED