000305754 001__ 305754
000305754 005__ 20251113115742.0
000305754 0247_ $$2doi$$a10.1002/nbm.70173
000305754 0247_ $$2pmid$$apmid:41217215
000305754 0247_ $$2ISSN$$a0952-3480
000305754 0247_ $$2ISSN$$a1099-1492
000305754 037__ $$aDKFZ-2025-02374
000305754 041__ $$aEnglish
000305754 082__ $$a610
000305754 1001_ $$aRoesli, Etienne$$b0
000305754 245__ $$aNon-Invasive Real-Time Detection of Potassium Level Changes in Skeletal Muscles During Exercise by Magnetic Resonance Spectroscopy.
000305754 260__ $$aNew York, NY$$bWiley$$c2025
000305754 3367_ $$2DRIVER$$aarticle
000305754 3367_ $$2DataCite$$aOutput Types/Journal article
000305754 3367_ $$0PUB:(DE-HGF)16$$2PUB:(DE-HGF)$$aJournal Article$$bjournal$$mjournal$$s1762960174_3281639
000305754 3367_ $$2BibTeX$$aARTICLE
000305754 3367_ $$2ORCID$$aJOURNAL_ARTICLE
000305754 3367_ $$00$$2EndNote$$aJournal Article
000305754 520__ $$aPotassium is essential in cellular functions, with specific importance in muscle activity and cardiovascular health. It is the main intracellular cation in the human body, with 70% located in muscle. Traditional methods to measure potassium levels are invasive and lack specificity for intracellular concentrations. Recently, non-invasive in vivo investigation of K+ ion homeostasis has become feasible by using 39K magnetic resonance imaging (MRI) and MR spectroscopy (MRS) at ultrahigh magnetic fields. However, studies demonstrating the sensitivity of 39K MRI or MRS to detect potassium alterations in disease or upon intervention are sparse. This study utilizes 39K MRS to non-invasively track real-time intramuscular potassium changes during exercise, providing an assessment of potassium dynamics and exploring the potential for technical artifacts in the measurements. Five healthy subjects (three males, two females) were recruited to perform standardized dynamic knee extensions inside a 7T MR scanner. Potassium levels were measured using a 39K MRS protocol that included periods of rest, moderate, and heavy exercise followed by recovery. Additionally, possible measurement artifacts due to muscle movement or changes in coil position relative to the thigh were evaluated using 39K MRS and 1H MRI monitoring in separate sessions. The study revealed a consistent decrease in potassium levels during both moderate and heavy exercise, with an average decrease of 5%-6%. These changes were rapidly detectable and were reversed upon cessation of exercise, indicating effective in vivo monitoring capability. Possible experimental artifacts were investigated, and the results suggested not to be responsible for the detected potassium changes during exercise. The results of the non-localized 39K MRS measurements during exercise correlated well with expected physiological changes based on previous literature. The application of 39K MRS provides a valuable non-invasive tool for studying potassium dynamics in human skeletal muscle. This technique could enhance our understanding of muscle physiology and metabolic disorders. The ability to measure these changes in real time and non-invasively highlights the potential for clinical applications, including monitoring of diseases affecting muscle and cellular metabolism.
000305754 536__ $$0G:(DE-HGF)POF4-315$$a315 - Bildgebung und Radioonkologie (POF4-315)$$cPOF4-315$$fPOF IV$$x0
000305754 588__ $$aDataset connected to CrossRef, PubMed, , Journals: inrepo02.dkfz.de
000305754 650_7 $$2Other$$a39K
000305754 650_7 $$2Other$$aexercise
000305754 650_7 $$2Other$$ahomeostasis
000305754 650_7 $$2Other$$amagnetic resonance spectroscopy
000305754 650_7 $$2Other$$apotassium
000305754 7001_ $$aPrimasová, Hedvika Haindrich$$b1
000305754 7001_ $$aThiede, Marc$$b2
000305754 7001_ $$aMani, Laila-Yasmin$$b3
000305754 7001_ $$aGast, Lena V$$b4
000305754 7001_ $$0P:(DE-He78)054fd7a5195b75b11fbdc5c360276011$$aNagel, Armin$$b5$$udkfz
000305754 7001_ $$aVogt, Bruno$$b6
000305754 7001_ $$aVermathen, Peter$$b7
000305754 773__ $$0PERI:(DE-600)2002003-X$$a10.1002/nbm.70173$$gVol. 38, no. 12, p. e70173$$n12$$pe70173$$tNMR in biomedicine$$v38$$x0952-3480$$y2025
000305754 909CO $$ooai:inrepo02.dkfz.de:305754$$pVDB
000305754 9101_ $$0I:(DE-588b)2036810-0$$6P:(DE-He78)054fd7a5195b75b11fbdc5c360276011$$aDeutsches Krebsforschungszentrum$$b5$$kDKFZ
000305754 9131_ $$0G:(DE-HGF)POF4-315$$1G:(DE-HGF)POF4-310$$2G:(DE-HGF)POF4-300$$3G:(DE-HGF)POF4$$4G:(DE-HGF)POF$$aDE-HGF$$bGesundheit$$lKrebsforschung$$vBildgebung und Radioonkologie$$x0
000305754 9141_ $$y2025
000305754 915__ $$0StatID:(DE-HGF)0420$$2StatID$$aNationallizenz$$d2024-12-12$$wger
000305754 915__ $$0StatID:(DE-HGF)3001$$2StatID$$aDEAL Wiley$$d2024-12-12$$wger
000305754 915__ $$0StatID:(DE-HGF)0200$$2StatID$$aDBCoverage$$bSCOPUS$$d2024-12-12
000305754 915__ $$0StatID:(DE-HGF)0300$$2StatID$$aDBCoverage$$bMedline$$d2024-12-12
000305754 915__ $$0StatID:(DE-HGF)0199$$2StatID$$aDBCoverage$$bClarivate Analytics Master Journal List$$d2024-12-12
000305754 915__ $$0StatID:(DE-HGF)0160$$2StatID$$aDBCoverage$$bEssential Science Indicators$$d2024-12-12
000305754 915__ $$0StatID:(DE-HGF)1030$$2StatID$$aDBCoverage$$bCurrent Contents - Life Sciences$$d2024-12-12
000305754 915__ $$0StatID:(DE-HGF)0113$$2StatID$$aWoS$$bScience Citation Index Expanded$$d2024-12-12
000305754 915__ $$0StatID:(DE-HGF)0150$$2StatID$$aDBCoverage$$bWeb of Science Core Collection$$d2024-12-12
000305754 915__ $$0StatID:(DE-HGF)0100$$2StatID$$aJCR$$bNMR BIOMED : 2022$$d2024-12-12
000305754 915__ $$0StatID:(DE-HGF)9900$$2StatID$$aIF < 5$$d2024-12-12
000305754 9201_ $$0I:(DE-He78)E020-20160331$$kE020$$lE020 Med. Physik in der Radiologie$$x0
000305754 980__ $$ajournal
000305754 980__ $$aVDB
000305754 980__ $$aI:(DE-He78)E020-20160331
000305754 980__ $$aUNRESTRICTED