000128231 001__ 128231
000128231 005__ 20240228145537.0
000128231 0247_ $$2doi$$a10.1002/mp.12251
000128231 0247_ $$2pmid$$apmid:28370020
000128231 0247_ $$2ISSN$$a0094-2405
000128231 0247_ $$2ISSN$$a1522-8541
000128231 0247_ $$2altmetric$$aaltmetric:18379224
000128231 037__ $$aDKFZ-2017-04248
000128231 041__ $$aeng
000128231 082__ $$a610
000128231 1001_ $$0P:(DE-He78)59c02b7b30ad8972cf422bb1c955956c$$aWieser, Hans-Peter$$b0$$eFirst author
000128231 245__ $$aDevelopment of the open-source dose calculation and optimization toolkit matRad.
000128231 260__ $$aNew York, NY$$c2017
000128231 3367_ $$2DRIVER$$aarticle
000128231 3367_ $$2DataCite$$aOutput Types/Journal article
000128231 3367_ $$0PUB:(DE-HGF)16$$2PUB:(DE-HGF)$$aJournal Article$$bjournal$$mjournal$$s1511261326_9860
000128231 3367_ $$2BibTeX$$aARTICLE
000128231 3367_ $$2ORCID$$aJOURNAL_ARTICLE
000128231 3367_ $$00$$2EndNote$$aJournal Article
000128231 520__ $$aWe report on the development of the open-source cross-platform radiation treatment planning toolkit matRad and its comparison against validated treatment planning systems. The toolkit enables three-dimensional intensity-modulated radiation therapy treatment planning for photons, scanned protons and scanned carbon ions.matRad is entirely written in Matlab and is freely available online. It re-implements well-established algorithms employing a modular and sequential software design to model the entire treatment planning workflow. It comprises core functionalities to import DICOM data, to calculate and optimize dose as well as a graphical user interface for visualization. matRad dose calculation algorithms (for carbon ions this also includes the computation of the relative biological effect) are compared against dose calculation results originating from clinically approved treatment planning systems.We observe three-dimensional γ-analysis pass rates ≥ 99.67% for all three radiation modalities utilizing a distance to agreement of 2 mm and a dose difference criterion of 2%. The computational efficiency of matRad is evaluated in a treatment planning study considering three different treatment scenarios for every radiation modality. For photons, we measure total run times of 145 s-1260 s for dose calculation and fluence optimization combined considering 4-72 beam orientations and 2608-13597 beamlets. For charged particles, we measure total run times of 63 s-993 s for dose calculation and fluence optimization combined considering 9963-45574 pencil beams. Using a CT and dose grid resolution of 0.3 cm(3) requires a memory consumption of 1.59 GB-9.07 GB and 0.29 GB-17.94 GB for photons and charged particles, respectively.The dosimetric accuracy, computational performance and open-source character of matRad encourages a future application of matRad for both educational and research purposes.
000128231 536__ $$0G:(DE-HGF)POF3-315$$a315 - Imaging and radiooncology (POF3-315)$$cPOF3-315$$fPOF III$$x0
000128231 588__ $$aDataset connected to CrossRef, PubMed,
000128231 7001_ $$0P:(DE-HGF)0$$aCisternas, Eduardo$$b1
000128231 7001_ $$0P:(DE-He78)dfd5aaf608015baaaed0a15b473f1336$$aWahl, Niklas$$b2
000128231 7001_ $$0P:(DE-He78)84f1e7432f32ce7df9064fa665afc191$$aUlrich, Silke$$b3
000128231 7001_ $$0P:(DE-He78)efcc1c3a629fc60fadc148f74c88811e$$aStadler, Alexander$$b4
000128231 7001_ $$0P:(DE-He78)c2ae1305c3f54907b473d564b973e424$$aMescher, Henning$$b5
000128231 7001_ $$0P:(DE-He78)8d14cee85833a37a0fa389fbf7552025$$aMüller, Lucas-Raphael$$b6
000128231 7001_ $$0P:(DE-HGF)0$$aKlinge, Thomas$$b7
000128231 7001_ $$0P:(DE-He78)ee06f8e4345f9f83ac70f0bce435f58a$$aGabrys, Hubert$$b8
000128231 7001_ $$0P:(DE-He78)914adea2baeb4f2c6a29637da6500048$$aBurigo, Lucas Norberto$$b9
000128231 7001_ $$aMairani, Andrea$$b10
000128231 7001_ $$aEcker, Swantje$$b11
000128231 7001_ $$aAckermann, Benjamin$$b12
000128231 7001_ $$aEllerbrock, Malte$$b13
000128231 7001_ $$aParodi, Katia$$b14
000128231 7001_ $$0P:(DE-He78)440a3f62ea9ea5c63375308976fc4c44$$aJäkel, Oliver$$b15$$udkfz
000128231 7001_ $$0P:(DE-He78)fec480a99b1869ec73688e95c2f0a43b$$aBangert, Mark$$b16$$eLast author
000128231 773__ $$0PERI:(DE-600)1466421-5$$a10.1002/mp.12251$$gVol. 44, no. 6, p. 2556 - 2568$$n6$$p2556 - 2568$$tMedical physics$$v44$$x0094-2405$$y2017
000128231 909CO $$ooai:inrepo02.dkfz.de:128231$$pVDB
000128231 9101_ $$0I:(DE-588b)2036810-0$$6P:(DE-He78)59c02b7b30ad8972cf422bb1c955956c$$aDeutsches Krebsforschungszentrum$$b0$$kDKFZ
000128231 9101_ $$0I:(DE-588b)2036810-0$$6P:(DE-HGF)0$$aDeutsches Krebsforschungszentrum$$b1$$kDKFZ
000128231 9101_ $$0I:(DE-588b)2036810-0$$6P:(DE-He78)dfd5aaf608015baaaed0a15b473f1336$$aDeutsches Krebsforschungszentrum$$b2$$kDKFZ
000128231 9101_ $$0I:(DE-588b)2036810-0$$6P:(DE-He78)84f1e7432f32ce7df9064fa665afc191$$aDeutsches Krebsforschungszentrum$$b3$$kDKFZ
000128231 9101_ $$0I:(DE-588b)2036810-0$$6P:(DE-He78)efcc1c3a629fc60fadc148f74c88811e$$aDeutsches Krebsforschungszentrum$$b4$$kDKFZ
000128231 9101_ $$0I:(DE-588b)2036810-0$$6P:(DE-He78)c2ae1305c3f54907b473d564b973e424$$aDeutsches Krebsforschungszentrum$$b5$$kDKFZ
000128231 9101_ $$0I:(DE-588b)2036810-0$$6P:(DE-He78)8d14cee85833a37a0fa389fbf7552025$$aDeutsches Krebsforschungszentrum$$b6$$kDKFZ
000128231 9101_ $$0I:(DE-588b)2036810-0$$6P:(DE-HGF)0$$aDeutsches Krebsforschungszentrum$$b7$$kDKFZ
000128231 9101_ $$0I:(DE-588b)2036810-0$$6P:(DE-He78)ee06f8e4345f9f83ac70f0bce435f58a$$aDeutsches Krebsforschungszentrum$$b8$$kDKFZ
000128231 9101_ $$0I:(DE-588b)2036810-0$$6P:(DE-He78)914adea2baeb4f2c6a29637da6500048$$aDeutsches Krebsforschungszentrum$$b9$$kDKFZ
000128231 9101_ $$0I:(DE-588b)2036810-0$$6P:(DE-He78)440a3f62ea9ea5c63375308976fc4c44$$aDeutsches Krebsforschungszentrum$$b15$$kDKFZ
000128231 9101_ $$0I:(DE-588b)2036810-0$$6P:(DE-He78)fec480a99b1869ec73688e95c2f0a43b$$aDeutsches Krebsforschungszentrum$$b16$$kDKFZ
000128231 9131_ $$0G:(DE-HGF)POF3-315$$1G:(DE-HGF)POF3-310$$2G:(DE-HGF)POF3-300$$3G:(DE-HGF)POF3$$4G:(DE-HGF)POF$$aDE-HGF$$bGesundheit$$lKrebsforschung$$vImaging and radiooncology$$x0
000128231 9141_ $$y2017
000128231 915__ $$0StatID:(DE-HGF)0100$$2StatID$$aJCR$$bMED PHYS : 2015
000128231 915__ $$0StatID:(DE-HGF)0200$$2StatID$$aDBCoverage$$bSCOPUS
000128231 915__ $$0StatID:(DE-HGF)0300$$2StatID$$aDBCoverage$$bMedline
000128231 915__ $$0StatID:(DE-HGF)0600$$2StatID$$aDBCoverage$$bEbsco Academic Search
000128231 915__ $$0StatID:(DE-HGF)0030$$2StatID$$aPeer Review$$bASC
000128231 915__ $$0StatID:(DE-HGF)0199$$2StatID$$aDBCoverage$$bThomson Reuters Master Journal List
000128231 915__ $$0StatID:(DE-HGF)0110$$2StatID$$aWoS$$bScience Citation Index
000128231 915__ $$0StatID:(DE-HGF)0150$$2StatID$$aDBCoverage$$bWeb of Science Core Collection
000128231 915__ $$0StatID:(DE-HGF)0111$$2StatID$$aWoS$$bScience Citation Index Expanded
000128231 915__ $$0StatID:(DE-HGF)1110$$2StatID$$aDBCoverage$$bCurrent Contents - Clinical Medicine
000128231 915__ $$0StatID:(DE-HGF)1030$$2StatID$$aDBCoverage$$bCurrent Contents - Life Sciences
000128231 915__ $$0StatID:(DE-HGF)9900$$2StatID$$aIF < 5
000128231 9201_ $$0I:(DE-He78)E040-20160331$$kE040$$lMedizinische Physik in der Strahlentherapie$$x0
000128231 9201_ $$0I:(DE-He78)E210-20160331$$kE210$$lTranslationale Radioonkologie$$x1
000128231 980__ $$ajournal
000128231 980__ $$aVDB
000128231 980__ $$aI:(DE-He78)E040-20160331
000128231 980__ $$aI:(DE-He78)E210-20160331
000128231 980__ $$aUNRESTRICTED