Journal Article DKFZ-2017-04248

http://join2-wiki.gsi.de/foswiki/pub/Main/Artwork/join2_logo100x88.png
Development of the open-source dose calculation and optimization toolkit matRad.

 ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;

2017
New York, NY

Medical physics 44(6), 2556 - 2568 () [10.1002/mp.12251]
 GO

This record in other databases:  

Please use a persistent id in citations: doi:

Abstract: We report on the development of the open-source cross-platform radiation treatment planning toolkit matRad and its comparison against validated treatment planning systems. The toolkit enables three-dimensional intensity-modulated radiation therapy treatment planning for photons, scanned protons and scanned carbon ions.matRad is entirely written in Matlab and is freely available online. It re-implements well-established algorithms employing a modular and sequential software design to model the entire treatment planning workflow. It comprises core functionalities to import DICOM data, to calculate and optimize dose as well as a graphical user interface for visualization. matRad dose calculation algorithms (for carbon ions this also includes the computation of the relative biological effect) are compared against dose calculation results originating from clinically approved treatment planning systems.We observe three-dimensional γ-analysis pass rates ≥ 99.67% for all three radiation modalities utilizing a distance to agreement of 2 mm and a dose difference criterion of 2%. The computational efficiency of matRad is evaluated in a treatment planning study considering three different treatment scenarios for every radiation modality. For photons, we measure total run times of 145 s-1260 s for dose calculation and fluence optimization combined considering 4-72 beam orientations and 2608-13597 beamlets. For charged particles, we measure total run times of 63 s-993 s for dose calculation and fluence optimization combined considering 9963-45574 pencil beams. Using a CT and dose grid resolution of 0.3 cm(3) requires a memory consumption of 1.59 GB-9.07 GB and 0.29 GB-17.94 GB for photons and charged particles, respectively.The dosimetric accuracy, computational performance and open-source character of matRad encourages a future application of matRad for both educational and research purposes.

Classification:

Contributing Institute(s):
  1. Medizinische Physik in der Strahlentherapie (E040)
  2. Translationale Radioonkologie (E210)
Research Program(s):
  1. 315 - Imaging and radiooncology (POF3-315) (POF3-315)

Appears in the scientific report 2017
Database coverage:
Medline ; Current Contents - Clinical Medicine ; Current Contents - Life Sciences ; Ebsco Academic Search ; IF < 5 ; JCR ; SCOPUS ; Science Citation Index ; Science Citation Index Expanded ; Thomson Reuters Master Journal List ; Web of Science Core Collection
Click to display QR Code for this record

The record appears in these collections:
Document types > Articles > Journal Article
Institute Collections > E040
Public records
Publications database

 Record created 2017-10-12, last modified 2024-02-28



Rate this document:

Rate this document:
1
2
3
 
(Not yet reviewed)