Home > Publications database > Improved clinical workflow for simultaneous whole-body PET/MRI using high-resolution CAIPIRINHA-accelerated MR-based attenuation correction. > print |
001 | 130782 | ||
005 | 20240228145553.0 | ||
024 | 7 | _ | |a 10.1016/j.ejrad.2017.09.007 |2 doi |
024 | 7 | _ | |a pmid:29103469 |2 pmid |
024 | 7 | _ | |a 0720-048X |2 ISSN |
024 | 7 | _ | |a 1872-7727 |2 ISSN |
037 | _ | _ | |a DKFZ-2017-05860 |
041 | _ | _ | |a eng |
082 | _ | _ | |a 610 |
100 | 1 | _ | |a Freitag, Martin |0 P:(DE-He78)c420f6efccb409e1a287be027501a74c |b 0 |e First author |u dkfz |
245 | _ | _ | |a Improved clinical workflow for simultaneous whole-body PET/MRI using high-resolution CAIPIRINHA-accelerated MR-based attenuation correction. |
260 | _ | _ | |a Amsterdam [u.a.] |c 2017 |b Elsevier Science |
336 | 7 | _ | |a article |2 DRIVER |
336 | 7 | _ | |a Output Types/Journal article |2 DataCite |
336 | 7 | _ | |a Journal Article |b journal |m journal |0 PUB:(DE-HGF)16 |s 1525780241_20626 |2 PUB:(DE-HGF) |
336 | 7 | _ | |a ARTICLE |2 BibTeX |
336 | 7 | _ | |a JOURNAL_ARTICLE |2 ORCID |
336 | 7 | _ | |a Journal Article |0 0 |2 EndNote |
520 | _ | _ | |a To explore the value and reproducibility of a novel magnetic resonance based attenuation correction (MRAC) using a CAIPIRINHA-accelerated T1-weighted Dixon 3D-VIBE sequence for whole-body PET/MRI compared to the clinical standard.The PET raw data of 19 patients from clinical routine were reconstructed with standard MRAC (MRACstd) and the novel MRAC (MRACcaipi), a prototype CAIPIRINHA accelerated Dixon 3D-VIBE sequence, both acquired in 19 s/bed position. Volume of interests (VOIs) for liver, lung and all voxels of the total image stack were created to calculate standardized uptake values (SUVmean) followed by inter-method agreement (Passing-Bablok regression, Bland-Altman analysis). A voxel-wise SUV comparison per patient was performed for intra-individual correlation between MRACstd and MRACcaipi. Difference images (MRACstd-MRACcaipi) of attenuation maps and SUV images were calculated. The image quality of in/opposed-phase water and fat images obtained from MRACcaipi was assessed by two readers on a 5-point Likert-scale including intra-class coefficients for inter-reader agreement.SUVmean correlations of VOIs demonstrated high linearity (0.95 |
536 | _ | _ | |a 315 - Imaging and radiooncology (POF3-315) |0 G:(DE-HGF)POF3-315 |c POF3-315 |f POF III |x 0 |
588 | _ | _ | |a Dataset connected to CrossRef, PubMed, |
700 | 1 | _ | |a Fenchel, Matthias |b 1 |
700 | 1 | _ | |a Bäumer, Philipp |0 P:(DE-He78)4a14b13a372ab8bf853e4b650a6bd98a |b 2 |u dkfz |
700 | 1 | _ | |a Heußer, Thorsten |0 P:(DE-He78)a00a109668c5fdbeea213d6981588250 |b 3 |u dkfz |
700 | 1 | _ | |a Rank, Christopher |0 P:(DE-He78)65dc5d2a03aac87b199cba2986986d05 |b 4 |u dkfz |
700 | 1 | _ | |a Kachelrieß, Marc |0 P:(DE-He78)f288a8f92f092ddb41d52b1aeb915323 |b 5 |u dkfz |
700 | 1 | _ | |a Paech, Daniel |0 P:(DE-He78)c6e31fb8f19e185e254174554a0cccfc |b 6 |u dkfz |
700 | 1 | _ | |a Kopka, Klaus |0 P:(DE-He78)9793347ba83f527b81a22ab75af9378a |b 7 |u dkfz |
700 | 1 | _ | |a Bickelhaupt, Sebastian |0 P:(DE-He78)d2d971750bce6217eb90fff9b01e61f9 |b 8 |u dkfz |
700 | 1 | _ | |a Dimitrakopoulou-Strauss, Antonia |0 P:(DE-He78)b2df3652dfa3e19d5e96dfc53f44a992 |b 9 |u dkfz |
700 | 1 | _ | |a Maier-Hein, Klaus |0 P:(DE-He78)33c74005e1ce56f7025c4f6be15321b3 |b 10 |u dkfz |
700 | 1 | _ | |a Floca, Ralf Omar |0 P:(DE-He78)f0ab09cfecf353f363bab4cc983de95d |b 11 |u dkfz |
700 | 1 | _ | |a Ladd, Mark |0 P:(DE-He78)022611a2317e4de40fd912e0a72293a8 |b 12 |u dkfz |
700 | 1 | _ | |a Schlemmer, Heinz-Peter |0 P:(DE-He78)3d04c8fee58c9ab71f62ff80d06b6fec |b 13 |u dkfz |
700 | 1 | _ | |a Maier, Florian |0 P:(DE-He78)4b912fbf89e1e4d1c8eb72b0ea07683a |b 14 |e Last author |u dkfz |
773 | _ | _ | |a 10.1016/j.ejrad.2017.09.007 |g Vol. 96, p. 12 - 20 |0 PERI:(DE-600)2005350-2 |p 12 - 20 |t European journal of radiology |v 96 |y 2017 |x 0720-048X |
909 | C | O | |o oai:inrepo02.dkfz.de:130782 |p VDB |
910 | 1 | _ | |a Deutsches Krebsforschungszentrum |0 I:(DE-588b)2036810-0 |k DKFZ |b 0 |6 P:(DE-He78)c420f6efccb409e1a287be027501a74c |
910 | 1 | _ | |a Deutsches Krebsforschungszentrum |0 I:(DE-588b)2036810-0 |k DKFZ |b 2 |6 P:(DE-He78)4a14b13a372ab8bf853e4b650a6bd98a |
910 | 1 | _ | |a Deutsches Krebsforschungszentrum |0 I:(DE-588b)2036810-0 |k DKFZ |b 3 |6 P:(DE-He78)a00a109668c5fdbeea213d6981588250 |
910 | 1 | _ | |a Deutsches Krebsforschungszentrum |0 I:(DE-588b)2036810-0 |k DKFZ |b 4 |6 P:(DE-He78)65dc5d2a03aac87b199cba2986986d05 |
910 | 1 | _ | |a Deutsches Krebsforschungszentrum |0 I:(DE-588b)2036810-0 |k DKFZ |b 5 |6 P:(DE-He78)f288a8f92f092ddb41d52b1aeb915323 |
910 | 1 | _ | |a Deutsches Krebsforschungszentrum |0 I:(DE-588b)2036810-0 |k DKFZ |b 6 |6 P:(DE-He78)c6e31fb8f19e185e254174554a0cccfc |
910 | 1 | _ | |a Deutsches Krebsforschungszentrum |0 I:(DE-588b)2036810-0 |k DKFZ |b 7 |6 P:(DE-He78)9793347ba83f527b81a22ab75af9378a |
910 | 1 | _ | |a Deutsches Krebsforschungszentrum |0 I:(DE-588b)2036810-0 |k DKFZ |b 8 |6 P:(DE-He78)d2d971750bce6217eb90fff9b01e61f9 |
910 | 1 | _ | |a Deutsches Krebsforschungszentrum |0 I:(DE-588b)2036810-0 |k DKFZ |b 9 |6 P:(DE-He78)b2df3652dfa3e19d5e96dfc53f44a992 |
910 | 1 | _ | |a Deutsches Krebsforschungszentrum |0 I:(DE-588b)2036810-0 |k DKFZ |b 10 |6 P:(DE-He78)33c74005e1ce56f7025c4f6be15321b3 |
910 | 1 | _ | |a Deutsches Krebsforschungszentrum |0 I:(DE-588b)2036810-0 |k DKFZ |b 11 |6 P:(DE-He78)f0ab09cfecf353f363bab4cc983de95d |
910 | 1 | _ | |a Deutsches Krebsforschungszentrum |0 I:(DE-588b)2036810-0 |k DKFZ |b 12 |6 P:(DE-He78)022611a2317e4de40fd912e0a72293a8 |
910 | 1 | _ | |a Deutsches Krebsforschungszentrum |0 I:(DE-588b)2036810-0 |k DKFZ |b 13 |6 P:(DE-He78)3d04c8fee58c9ab71f62ff80d06b6fec |
910 | 1 | _ | |a Deutsches Krebsforschungszentrum |0 I:(DE-588b)2036810-0 |k DKFZ |b 14 |6 P:(DE-He78)4b912fbf89e1e4d1c8eb72b0ea07683a |
913 | 1 | _ | |a DE-HGF |l Krebsforschung |1 G:(DE-HGF)POF3-310 |0 G:(DE-HGF)POF3-315 |2 G:(DE-HGF)POF3-300 |v Imaging and radiooncology |x 0 |4 G:(DE-HGF)POF |3 G:(DE-HGF)POF3 |b Gesundheit |
914 | 1 | _ | |y 2017 |
915 | _ | _ | |a Nationallizenz |0 StatID:(DE-HGF)0420 |2 StatID |
915 | _ | _ | |a JCR |0 StatID:(DE-HGF)0100 |2 StatID |b EUR J RADIOL : 2015 |
915 | _ | _ | |a DBCoverage |0 StatID:(DE-HGF)0200 |2 StatID |b SCOPUS |
915 | _ | _ | |a DBCoverage |0 StatID:(DE-HGF)0300 |2 StatID |b Medline |
915 | _ | _ | |a DBCoverage |0 StatID:(DE-HGF)0600 |2 StatID |b Ebsco Academic Search |
915 | _ | _ | |a Peer Review |0 StatID:(DE-HGF)0030 |2 StatID |b ASC |
915 | _ | _ | |a DBCoverage |0 StatID:(DE-HGF)0199 |2 StatID |b Thomson Reuters Master Journal List |
915 | _ | _ | |a WoS |0 StatID:(DE-HGF)0111 |2 StatID |b Science Citation Index Expanded |
915 | _ | _ | |a DBCoverage |0 StatID:(DE-HGF)0150 |2 StatID |b Web of Science Core Collection |
915 | _ | _ | |a DBCoverage |0 StatID:(DE-HGF)1110 |2 StatID |b Current Contents - Clinical Medicine |
915 | _ | _ | |a IF < 5 |0 StatID:(DE-HGF)9900 |2 StatID |
920 | 1 | _ | |0 I:(DE-He78)E010-20160331 |k E010 |l Radiologie |x 0 |
920 | 1 | _ | |0 I:(DE-He78)E020-20160331 |k E020 |l Medizinische Physik in der Radiologie |x 1 |
920 | 1 | _ | |0 I:(DE-He78)E025-20160331 |k E025 |l Radiologie_Legacy_ |x 2 |
920 | 1 | _ | |0 I:(DE-He78)E030-20160331 |k E030 |l Radiopharmazeutische Chemie |x 3 |
920 | 1 | _ | |0 I:(DE-He78)E060-20160331 |k E060 |l KKE Nuklearmedizin |x 4 |
920 | 1 | _ | |0 I:(DE-He78)E132-20160331 |k E132 |l Medizinische Bildverarbeitung |x 5 |
920 | 1 | _ | |0 I:(DE-He78)E071-20160331 |k E071 |l Softwareentwicklung für Integrierte Diagnostik und Therapie(SIDT) |x 6 |
980 | _ | _ | |a journal |
980 | _ | _ | |a VDB |
980 | _ | _ | |a I:(DE-He78)E010-20160331 |
980 | _ | _ | |a I:(DE-He78)E020-20160331 |
980 | _ | _ | |a I:(DE-He78)E025-20160331 |
980 | _ | _ | |a I:(DE-He78)E030-20160331 |
980 | _ | _ | |a I:(DE-He78)E060-20160331 |
980 | _ | _ | |a I:(DE-He78)E132-20160331 |
980 | _ | _ | |a I:(DE-He78)E071-20160331 |
980 | _ | _ | |a UNRESTRICTED |
Library | Collection | CLSMajor | CLSMinor | Language | Author |
---|