Journal Article DKFZ-2017-05860

http://join2-wiki.gsi.de/foswiki/pub/Main/Artwork/join2_logo100x88.png
Improved clinical workflow for simultaneous whole-body PET/MRI using high-resolution CAIPIRINHA-accelerated MR-based attenuation correction.

 ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;

2017
Elsevier Science Amsterdam [u.a.]

European journal of radiology 96, 12 - 20 () [10.1016/j.ejrad.2017.09.007]
 GO

This record in other databases:

Please use a persistent id in citations: doi:

Abstract: To explore the value and reproducibility of a novel magnetic resonance based attenuation correction (MRAC) using a CAIPIRINHA-accelerated T1-weighted Dixon 3D-VIBE sequence for whole-body PET/MRI compared to the clinical standard.The PET raw data of 19 patients from clinical routine were reconstructed with standard MRAC (MRACstd) and the novel MRAC (MRACcaipi), a prototype CAIPIRINHA accelerated Dixon 3D-VIBE sequence, both acquired in 19 s/bed position. Volume of interests (VOIs) for liver, lung and all voxels of the total image stack were created to calculate standardized uptake values (SUVmean) followed by inter-method agreement (Passing-Bablok regression, Bland-Altman analysis). A voxel-wise SUV comparison per patient was performed for intra-individual correlation between MRACstd and MRACcaipi. Difference images (MRACstd-MRACcaipi) of attenuation maps and SUV images were calculated. The image quality of in/opposed-phase water and fat images obtained from MRACcaipi was assessed by two readers on a 5-point Likert-scale including intra-class coefficients for inter-reader agreement.SUVmean correlations of VOIs demonstrated high linearity (0.95<Spearman's rho<1, p<0.0001, respectively), substantiated by voxel-wise SUV scatter-plots (1.79×10(8) pixels). Outliers could be explained by different physiological conditions between the scans such as different segmentation of air-containing tissue, lungs, kidneys, metal implants, diaphragm edge or small air bubbles in the gastrointestinal tracts that moved between MRAC acquisitions. Nasal sinuses and the trachea were better segmented in MRACcaipi. High-resolution T1w Dixon 3D VIBE images were acquired in all cases and could be used for PET/MRI fusion. MRACcaipi images were of high diagnostic quality (4.2±0.8) with 0.92-0.96 intra-class correlation.The novel prototype MRACcaipi extends the value for attenuation correction by providing a high spatial resolution DIXON-based dataset suited for diagnostic assessment towards time-efficient whole-body PET/MRI.

Classification:

Contributing Institute(s):
  1. Radiologie (E010)
  2. Medizinische Physik in der Radiologie (E020)
  3. Radiologie_Legacy_ (E025)
  4. Radiopharmazeutische Chemie (E030)
  5. KKE Nuklearmedizin (E060)
  6. Medizinische Bildverarbeitung (E132)
  7. Softwareentwicklung für Integrierte Diagnostik und Therapie(SIDT) (E071)
Research Program(s):
  1. 315 - Imaging and radiooncology (POF3-315) (POF3-315)

Appears in the scientific report 2017
Database coverage:
Medline ; Current Contents - Clinical Medicine ; Ebsco Academic Search ; IF < 5 ; JCR ; NationallizenzNationallizenz ; SCOPUS ; Science Citation Index Expanded ; Thomson Reuters Master Journal List ; Web of Science Core Collection
Click to display QR Code for this record

The record appears in these collections:
Document types > Articles > Journal Article
Institute Collections > E010
Institute Collections > E025
Institute Collections > E020
Public records
Publications database

 Record created 2017-11-24, last modified 2024-02-28



Rate this document:

Rate this document:
1
2
3
 
(Not yet reviewed)