Journal Article DKFZ-2019-01854

http://join2-wiki.gsi.de/foswiki/pub/Main/Artwork/join2_logo100x88.png
Mapping the human brainstem: Brain nuclei and fiber tracts at 3 T and 7 T.

 ;  ;  ;  ;  ;

2019
Wiley New York, NY

NMR in biomedicine 32(9), e4118 () [10.1002/nbm.4118]
 GO

This record in other databases:  

Please use a persistent id in citations: doi:

Abstract: Structural high-resolution imaging of the brainstem can be of high importance in clinical practice. However, ultra-high field magnetic resonance imaging (MRI) is still restricted in use due to limited availability. Therefore, quantitative MRI techniques (quantitative susceptibility mapping [QSM], relaxation measurements [ R 2 * , R1 ], diffusion tensor imaging [DTI]) and T2 - and proton density (PD)-weighted imaging in the human brainstem at 3 T and 7 T are compared. Five healthy volunteers (mean age: 21.5 ± 1.9 years) were measured at 3 T and 7 T using multi-echo gradient echo sequences for susceptibility mapping and R 2 * relaxometry, magnetization-prepared 2 rapid acquisition gradient echo sequences for R1 relaxometry, turbo-spin echo sequences for PD- and T2 -weighted imaging and readout-segmented echo planar sequences for DTI. Susceptibility maps were computed using Laplacian-based phase unwrapping, V-SHARP for background field removal and the streaking artifact reduction for QSM algorithm for dipole inversion. Contrast-to-noise ratios (CNRs) were determined at 3 T and 7 T in ten volumes of interest (VOIs). Data acquired at 7 T showed higher CNR. However, in four VOIs, lower CNR was observed for R 2 * at 7 T. QSM was shown to be the contrast with which the highest number of structures could be identified. The depiction of very fine tracts such as the medial longitudinal fasciculus throughout the brainstem was only possible in susceptibility maps acquired at 7 T. DTI effectively showed the main tracts (crus cerebri, transverse pontine fibers, corticospinal tract, middle and superior cerebellar peduncle, pontocerebellar tract, and pyramid) at both field strengths. Assessing the brainstem with quantitative MRI methods such as QSM, R 2 * , as well as PD- and T2 -weighted imaging with great detail, is also possible at 3 T, especially when using susceptibility mapping calculated from a gradient echo sequence with a wide range of echo times from 10.5 to 52.5 ms. However, tracing smallest structures strongly benefits from imaging at ultra-high field.

Classification:

Contributing Institute(s):
  1. Medizinische Physik in der Radiologie (E020)
Research Program(s):
  1. 315 - Imaging and radiooncology (POF3-315) (POF3-315)

Appears in the scientific report 2019
Database coverage:
Medline ; Clarivate Analytics Master Journal List ; Current Contents - Life Sciences ; IF < 5 ; JCR ; NCBI Molecular Biology Database ; NationallizenzNationallizenz ; SCOPUS ; Science Citation Index ; Science Citation Index Expanded ; Web of Science Core Collection
Click to display QR Code for this record

The record appears in these collections:
Document types > Articles > Journal Article
Institute Collections > E020
Public records
Publications database

 Record created 2019-08-07, last modified 2024-02-29



Rate this document:

Rate this document:
1
2
3
 
(Not yet reviewed)