| Home > Publications database > On the limitations of the area under the ROC curve for NTCP modelling. |
| Journal Article | DKFZ-2019-02970 |
;
2019
Elsevier Science
Amsterdam [u.a.]
This record in other databases:

Please use a persistent id in citations: doi:10.1016/j.radonc.2019.11.018
Abstract: The area under the ROC curve (AUC) is commonly used as a measure for the discriminative performance of NTCP models. Here, we demonstrate that for typical patient cohorts, the AUC is an unsuitable measure for that purpose since it is typically limited to values below 0.8 and it exhibits large statistical variation.
|