Abstract: To develop a reliable, consistent, and reproducible reference phantom for error quantification of phase-contrast MRI so it can be used for validation and quality control.An air-driven rotation phantom consisting of a steadily rotating cylinder surrounded by a static ring both filled with agarose gel was developed. Rotational speed was measured and controlled in real time using an optical counter and a closed-loop controller. Consistency of the phantom was assessed by recording variations in rotational speed. The phantom was imaged with 2D phase-contrast MRI, and the velocity at each point was compared with analytically predicted velocity. Additionally, to examine reproducibility, the phantom was run with the same rotational speed on 2 different days and imaged using the same phase-contrast MRI protocol.The rotation phantom provided consistent rotational speed with 2 revolutions per minute SD from the set value for 20 min. Comparison between predicted and measured velocities demonstrated excellent agreement (intraclass correlation coefficient of 0.99). The RMS error in velocity components were less than 1% of maximum value. The scan-rescan experiment showed that the phantom can reproduce the same velocity distributions (intraclass correlation coefficient of 0.99) using the same rotational speed and MRI settings.The developed rotation phantom provided well-defined and reproducible linear velocity distributions, which can be used for systematic and quantitative error analysis of phase-contrast MRI for a range of known velocities.

Classification:

Note: 2020 Dec;84(6):3333-3341

Contributing Institute(s):
  1. E020 Med. Physik in der Radiologie (E020)
Research Program(s):
  1. 315 - Imaging and radiooncology (POF3-315) (POF3-315)

Appears in the scientific report 2020
Database coverage:
Medline ; BIOSIS Previews ; Biological Abstracts ; Clarivate Analytics Master Journal List ; Current Contents - Clinical Medicine ; Current Contents - Life Sciences ; DEAL Wiley ; Essential Science Indicators ; IF < 5 ; JCR ; NationallizenzNationallizenz ; SCOPUS ; Science Citation Index ; Science Citation Index Expanded ; Web of Science Core Collection
Click to display QR Code for this record

The record appears in these collections:
Document types > Articles > Journal Article
Institute Collections > E020
Public records
Publications database

 Record created 2020-07-06, last modified 2024-02-29



Rate this document:

Rate this document:
1
2
3
 
(Not yet reviewed)