001     177447
005     20240229133740.0
037 _ _ |a DKFZ-2021-02539
100 1 _ |a Karle, Celine
|0 P:(DE-He78)433ef2e5b8d022ed267d20bce4bf6479
|b 0
|u dkfz
111 2 _ |a PTCOG 59
|c Taipei
|d 2021-06-04 - 2021-06-07
|w Taiwan
245 _ _ |a Investigating water radiolysis during proton mini and micro beam irradiation with TOPAS-nBio
260 _ _ |c 2021
336 7 _ |a Conference Paper
|0 33
|2 EndNote
336 7 _ |a Other
|2 DataCite
336 7 _ |a INPROCEEDINGS
|2 BibTeX
336 7 _ |a conferenceObject
|2 DRIVER
336 7 _ |a LECTURE_SPEECH
|2 ORCID
336 7 _ |a Conference Presentation
|b conf
|m conf
|0 PUB:(DE-HGF)6
|s 1637151793_19386
|2 PUB:(DE-HGF)
|x Invited
520 _ _ |a Authors: Celine Karle, Lucas Noberto Burigo, Riccardo Dal Bello, Joao SecoThe main focus of this project is to assess the chemical products of water radiolysis during proton mini and micro beams irradiation with TOPAS-nbio. Mini and micro beams are characterized by the alternation of high dose peaks and low dose valleys. The peak to valley distance commonly used is either millimeter or micrometer for mini or micro beam respectively. Molecular candidates, such as H2O2, are currently being investigated in order to potentially explain the mechanisms of this radiation therapy form.TOPAS-nbio is an extension of the TOPAS software to adjust it to radiobiological applications. Therefore, the MC simulation can be used to model the temporal production, interaction and diffusion of different radiolysis products. Firstly, a single proton beam, which irradiates a water phantom, is modeled. The produced chemical species during the pre-chemical and chemical state up to 1 µs are scored. The temporal change of the distribution of the molecules H2O2and HO2 of special interest since they reach a steady state after 1 µs, which could potentially explain the efficiency of micro and mini-beam radiation therapy.The steady-state conclusion has previously been drawn by the TRAX-CHEM simulation [Dal Bello, R., et al. (2020). Proposal of a Chemical Mechanism for Mini-Beam and Micro-Beam Efficacy, https://doi.org/10.3389/fphy.2020.564836]. To verify this finding, the temporal evolution of the relative abundance from the mentioned molecules and the H2O2 distribution with increasing distance from the beam axis is investigated with the TOPAS-nbio software and compared to the TRAX-CHEM results.
536 _ _ |a 315 - Bildgebung und Radioonkologie (POF4-315)
|0 G:(DE-HGF)POF4-315
|c POF4-315
|f POF IV
|x 0
700 1 _ |a Seco, Joao
|0 P:(DE-He78)102624aca75cfe987c05343d5fdcf2fe
|b 1
|e Corresponding author
|u dkfz
909 C O |o oai:inrepo02.dkfz.de:177447
|p VDB
910 1 _ |a Deutsches Krebsforschungszentrum
|0 I:(DE-588b)2036810-0
|k DKFZ
|b 0
|6 P:(DE-He78)433ef2e5b8d022ed267d20bce4bf6479
910 1 _ |a Deutsches Krebsforschungszentrum
|0 I:(DE-588b)2036810-0
|k DKFZ
|b 1
|6 P:(DE-He78)102624aca75cfe987c05343d5fdcf2fe
913 1 _ |a DE-HGF
|b Gesundheit
|l Krebsforschung
|1 G:(DE-HGF)POF4-310
|0 G:(DE-HGF)POF4-315
|3 G:(DE-HGF)POF4
|2 G:(DE-HGF)POF4-300
|4 G:(DE-HGF)POF
|v Bildgebung und Radioonkologie
|x 0
914 1 _ |y 2021
920 1 _ |0 I:(DE-He78)E041-20160331
|k E041
|l E041 Medizinische Physik in der Radioonkologie
|x 0
980 _ _ |a conf
980 _ _ |a VDB
980 _ _ |a I:(DE-He78)E041-20160331
980 _ _ |a UNRESTRICTED


LibraryCollectionCLSMajorCLSMinorLanguageAuthor
Marc 21