Abstract: Complexity in selecting optimal non-coplanar beam setups and prolonged delivery times may hamper the use of non-coplanar treatments for nasopharyngeal carcinoma (NPC). Automated multi-criterial planning with integrated beam angle optimization was used to define non-coplanar VMAT class solutions (CSs), each consisting of a coplanar arc and additional 1 or 2 fixed, non-coplanar partial arcs.Automated planning was used to generate a coplanar VMAT plan with 5 complementary computer-optimized non-coplanar IMRT beams (VMAT+5) for each of the 20 included patients. Subsequently, the frequency distribution of the 100 patient-specific non-coplanar IMRT beam directions was used to select non-coplanar arcs for supplementing coplanar VMAT. A second investigated CS with only one non-coplanar arc consisted of coplanar VMAT plus a partial arc at 90° couch angle (VMATCS90). Plans generated with the two VMATCSs were compared to coplanar VMAT.VMAT+5 analysis resulted in VMATCS60: two partial non-coplanar arcs at couch angles 60° and -60° to complement coplanar VMAT. Compared to coplanar VMAT, the non-coplanar VMATCS60 and VMATCS90 yielded substantial average dose reductions in OARs associated with xerostomia and dysphagia, i.e., parotids, submandibular glands, oral cavity and swallowing muscles (p < 0.05) for the same PTV coverage and without violating hard constraints. Impact of non-coplanar treatment and superiority of either VMACS60 and VMATCS90 was highly patient dependent.Compared to coplanar VMAT, dose to OARs was substantially reduced with a CS with one or two non-coplanar arcs. Preferences for coplanar or one or two additional arcs are highly patient-specific, balancing plan quality and treatment time.

Keyword(s): Automated multi-criterial planning with beam angle optimization ; Nasopharyngeal carcinoma ; Non-coplanar VMAT class solutions

Classification:

Note: #EA:E041#

Contributing Institute(s):
  1. E041 Medizinische Physik in der Radioonkologie (E041)
Research Program(s):
  1. 315 - Bildgebung und Radioonkologie (POF4-315) (POF4-315)

Appears in the scientific report 2022
Database coverage:
Medline ; Clarivate Analytics Master Journal List ; Current Contents - Clinical Medicine ; Essential Science Indicators ; IF < 5 ; JCR ; NationallizenzNationallizenz ; SCOPUS ; Science Citation Index Expanded ; Web of Science Core Collection
Click to display QR Code for this record

The record appears in these collections:
Document types > Articles > Journal Article
Public records
Publications database

 Record created 2022-07-20, last modified 2024-02-29



Rate this document:

Rate this document:
1
2
3
 
(Not yet reviewed)