Journal Article DKFZ-2022-01987

http://join2-wiki.gsi.de/foswiki/pub/Main/Artwork/join2_logo100x88.png
Mask-Adapted Background Field Removal for Artifact Reduction in Quantitative Susceptibility Mapping of the Prostate.

 ;  ;  ;  ;  ;  ;  ;

2017
Grapho Publications Ann Arbor, Michigan

Tomography 3(2), 96 - 100 () [10.18383/j.tom.2017.00005]
 GO

This record in other databases:

Please use a persistent id in citations: doi:

Abstract: We propose an alternative processing method for quantitative susceptibility mapping of the prostate that reduces artifacts and enables better visibility and quantification of calcifications and other lesions. Three-dimensional gradient-echo magnetic resonance data were obtained from 26 patients at 3 T who previously received a planning computed tomography of the prostate. Phase images were unwrapped using Laplacian-based phase unwrapping. The background field was removed with the V-SHARP method using tissue masks for the entire abdomen (Method 1) and masks that excluded bone and the rectum (Method 2). Susceptibility maps were calculated with the iLSQR method. The quality of susceptibility maps was assessed by one radiologist and two physicists who rated the data for visibility of lesions and data quality on a scale from 1 (poor) to 4 (good). The readers rated susceptibility maps computed with Method 2 to be, on average, better for visibility of lesions with a score of 2.9 ± 1.1 and image quality with a score of 2.8 ± 0.8 compared with maps computed with Method 1 (2.4 ± 1.2/2.3 ± 1.0). Regarding strong artifacts, these could be removed using adapted masks, and the susceptibility values seemed less biased by the artifacts. Thus, using an adapted mask for background field removal when calculating susceptibility maps of the prostate from phase data reduces artifacts and improves visibility of lesions.

Keyword(s): artifact reduction ; background field removal ; calcification ; prostate cancer ; quantitative susceptibility mapping

Classification:

Contributing Institute(s):
  1. E020 Med. Physik in der Radiologie (E020)
  2. E010 Radiologie (E010)
  3. Medizinische Bildverarbeitung (E132)
  4. E230 Medizinische Bildverarbeitung (E230)
Research Program(s):
  1. 315 - Imaging and radiooncology (POF3-315) (POF3-315)

Appears in the scientific report 2017
Database coverage:
Medline ; Clarivate Analytics Master Journal List ; Current Contents - Life Sciences ; Essential Science Indicators ; IF < 5 ; JCR ; PubMed Central ; SCOPUS ; Science Citation Index Expanded ; Web of Science Core Collection
Click to display QR Code for this record

The record appears in these collections:
Document types > Articles > Journal Article
Institute Collections > E010
Institute Collections > E020
Public records
Publications database

 Record created 2022-08-24, last modified 2024-03-01


Rate this document:

Rate this document:
1
2
3
 
(Not yet reviewed)