Journal Article DKFZ-2023-00016

http://join2-wiki.gsi.de/foswiki/pub/Main/Artwork/join2_logo100x88.png
Single-spoke binning: Reducing motion artifacts in abdominal radial stack-of-stars imaging.

 ;  ;  ;  ;  ;  ;  ;  ;

2023
Wiley-Liss New York, NY [u.a.]

Magnetic resonance in medicine 89(5), 1931-1944 () [10.1002/mrm.29576]
 GO

This record in other databases:  

Please use a persistent id in citations: doi:

Abstract: To increase the effectiveness of respiratory gating in radial stack-of-stars MRI, particularly when imaging at high spatial resolutions or with multiple echoes.Free induction decay (FID) navigators were integrated into a three-dimensional gradient echo radial stack-of-stars pulse sequence. These navigators provided a motion signal with a high temporal resolution, which allowed single-spoke binning (SSB): each spoke at each phase encode step was sorted individually to the corresponding motion state of the respiratory signal. SSB was compared with spoke-angle binning (SAB), in which all phase encode steps of one projection angle were sorted without the use of additional navigator data. To illustrate the benefit of SSB over SAB, images of a motion phantom and of six free-breathing volunteers were reconstructed after motion-gating using either method. Image sharpness was quantitatively compared using image gradient entropies.The proposed method resulted in sharper images of the motion phantom and free-breathing volunteers. Differences in gradient entropy were statistically significant (p = 0.03) in favor of SSB. The increased accuracy of motion-gating led to a decrease of streaking artifacts in motion-gated four-dimensional reconstructions. To consistently estimate respiratory signals from the FID-navigator data, specific types of gradient spoiler waveforms were required.SSB allowed high-resolution motion-corrected MR imaging, even when acquiring multiple gradient echo signals or large acquisition matrices, without sacrificing accuracy of motion-gating. SSB thus relieves restrictions on the choice of pulse sequence parameters, enabling the use of motion-gated radial stack-of-stars MRI in a broader domain of clinical applications.

Keyword(s): FID navigators ; motion binning ; motion correction ; radial sampling ; respiratory gating

Classification:

Note: 2023 May;89(5):1931-1944

Contributing Institute(s):
  1. E025 Röntgenbildgebung und Computertomographie (E025)
  2. KKE Pädiatrische Onkologie (B310)
  3. DKTK HD zentral (HD01)
Research Program(s):
  1. 315 - Bildgebung und Radioonkologie (POF4-315) (POF4-315)

Appears in the scientific report 2023
Database coverage:
Medline ; BIOSIS Previews ; Biological Abstracts ; Clarivate Analytics Master Journal List ; Current Contents - Clinical Medicine ; Current Contents - Life Sciences ; DEAL Wiley ; Essential Science Indicators ; IF < 5 ; JCR ; NationallizenzNationallizenz ; SCOPUS ; Science Citation Index Expanded ; Web of Science Core Collection
Click to display QR Code for this record

The record appears in these collections:
Document types > Articles > Journal Article
Institute Collections > E025
Public records
Publications database

 Record created 2023-01-03, last modified 2024-09-18



Rate this document:

Rate this document:
1
2
3
 
(Not yet reviewed)