001     286720
005     20250729140807.0
024 7 _ |a 10.1002/mrm.29978
|2 doi
024 7 _ |a pmid:38174601
|2 pmid
024 7 _ |a 1522-2594
|2 ISSN
024 7 _ |a 0740-3194
|2 ISSN
024 7 _ |a altmetric:158087506
|2 altmetric
037 _ _ |a DKFZ-2024-00060
041 _ _ |a English
082 _ _ |a 610
100 1 _ |a Degenhardt, Katja
|b 0
245 _ _ |a Toward accurate and fast velocity quantification with 3D ultrashort TE phase-contrast imaging.
260 _ _ |a New York, NY [u.a.]
|c 2024
|b Wiley-Liss
336 7 _ |a article
|2 DRIVER
336 7 _ |a Output Types/Journal article
|2 DataCite
336 7 _ |a Journal Article
|b journal
|m journal
|0 PUB:(DE-HGF)16
|s 1711008329_10705
|2 PUB:(DE-HGF)
336 7 _ |a ARTICLE
|2 BibTeX
336 7 _ |a JOURNAL_ARTICLE
|2 ORCID
336 7 _ |a Journal Article
|0 0
|2 EndNote
500 _ _ |a #LA:E020# / 2024 May;91(5):1994-2009
520 _ _ |a Traditional phase-contrast MRI is affected by displacement artifacts caused by non-synchronized spatial- and velocity-encoding time points. The resulting inaccurate velocity maps can affect the accuracy of derived hemodynamic parameters. This study proposes and characterizes a 3D radial phase-contrast UTE (PC-UTE) sequence to reduce displacement artifacts. Furthermore, it investigates the displacement of a standard Cartesian flow sequence by utilizing a displacement-free synchronized-single-point-imaging MR sequence (SYNC-SPI) that requires clinically prohibitively long acquisition times.3D flow data was acquired at 3T at three different constant flow rates and varying spatial resolutions in a stenotic aorta phantom using the proposed PC-UTE, a Cartesian flow sequence, and a SYNC-SPI sequence as reference. Expected displacement artifacts were calculated from gradient timing waveforms and compared to displacement values measured in the in vitro flow experiments.The PC-UTE sequence reduces displacement and intravoxel dephasing, leading to decreased geometric distortions and signal cancellations in magnitude images, and more spatially accurate velocity quantification compared to the Cartesian flow acquisitions; errors increase with velocity and higher spatial resolution.PC-UTE MRI can measure velocity vector fields with greater accuracy than Cartesian acquisitions (although pulsatile fields were not studied) and shorter scan times than SYNC-SPI. As such, this approach is superior to traditional Cartesian 3D and 4D flow MRI when spatial misrepresentations cannot be tolerated, for example, when computational fluid dynamics simulations are compared to or combined with in vitro or in vivo measurements, or regional parameters such as wall shear stress are of interest.
536 _ _ |a 315 - Bildgebung und Radioonkologie (POF4-315)
|0 G:(DE-HGF)POF4-315
|c POF4-315
|f POF IV
|x 0
588 _ _ |a Dataset connected to CrossRef, PubMed, , Journals: inrepo02.dkfz.de
650 _ 7 |a 4D flow MRI
|2 Other
650 _ 7 |a GIRF
|2 Other
650 _ 7 |a PC-UTE
|2 Other
650 _ 7 |a displacement artifact
|2 Other
650 _ 7 |a flow artifact
|2 Other
650 _ 7 |a gradient imperfections
|2 Other
700 1 _ |a Schmidt, Simon
|0 P:(DE-He78)549e123a16abe980dac951ef402f70ec
|b 1
700 1 _ |a Aigner, Christoph S
|0 0000-0003-3618-9610
|b 2
700 1 _ |a Kratzer, Fabian
|0 P:(DE-He78)0ad4af74a6b337e282ad0281595593bc
|b 3
|u dkfz
700 1 _ |a Seiter, Daniel P
|b 4
700 1 _ |a Mueller, Max
|0 0000-0001-6731-9583
|b 5
700 1 _ |a Kolbitsch, Christoph
|0 0000-0002-4355-8368
|b 6
700 1 _ |a Nagel, Armin
|0 P:(DE-He78)054fd7a5195b75b11fbdc5c360276011
|b 7
|u dkfz
700 1 _ |a Wieben, Oliver
|0 0000-0002-7931-1930
|b 8
700 1 _ |a Schaeffter, Tobias
|0 0000-0003-1310-2631
|b 9
700 1 _ |a Schulz-Menger, Jeanette
|0 0000-0003-3100-1092
|b 10
700 1 _ |a Schmitter, Sebastian
|0 P:(DE-He78)19e2d877276b0e5eec11cdfc1789a55e
|b 11
|e Last author
|u dkfz
773 _ _ |a 10.1002/mrm.29978
|g p. mrm.29978
|0 PERI:(DE-600)1493786-4
|n 5
|p 1994-2009
|t Magnetic resonance in medicine
|v 91
|y 2024
|x 1522-2594
856 4 _ |u https://inrepo02.dkfz.de/record/286720/files/Magnetic%20Resonance%20in%20Med%20-%202024%20-%20Degenhardt%20-%20Toward%20accurate%20and%20fast%20velocity%20quantification%20with%203D%20ultrashort%20TE.pdf
856 4 _ |u https://inrepo02.dkfz.de/record/286720/files/Magnetic%20Resonance%20in%20Med%20-%202024%20-%20Degenhardt%20-%20Toward%20accurate%20and%20fast%20velocity%20quantification%20with%203D%20ultrashort%20TE.pdf?subformat=pdfa
|x pdfa
909 C O |p VDB
|o oai:inrepo02.dkfz.de:286720
910 1 _ |a Deutsches Krebsforschungszentrum
|0 I:(DE-588b)2036810-0
|k DKFZ
|b 1
|6 P:(DE-He78)549e123a16abe980dac951ef402f70ec
910 1 _ |a Deutsches Krebsforschungszentrum
|0 I:(DE-588b)2036810-0
|k DKFZ
|b 3
|6 P:(DE-He78)0ad4af74a6b337e282ad0281595593bc
910 1 _ |a Deutsches Krebsforschungszentrum
|0 I:(DE-588b)2036810-0
|k DKFZ
|b 7
|6 P:(DE-He78)054fd7a5195b75b11fbdc5c360276011
910 1 _ |a Deutsches Krebsforschungszentrum
|0 I:(DE-588b)2036810-0
|k DKFZ
|b 11
|6 P:(DE-He78)19e2d877276b0e5eec11cdfc1789a55e
913 1 _ |a DE-HGF
|b Gesundheit
|l Krebsforschung
|1 G:(DE-HGF)POF4-310
|0 G:(DE-HGF)POF4-315
|3 G:(DE-HGF)POF4
|2 G:(DE-HGF)POF4-300
|4 G:(DE-HGF)POF
|v Bildgebung und Radioonkologie
|x 0
914 1 _ |y 2024
915 _ _ |a Nationallizenz
|0 StatID:(DE-HGF)0420
|2 StatID
|d 2023-10-21
|w ger
915 _ _ |a DEAL Wiley
|0 StatID:(DE-HGF)3001
|2 StatID
|d 2023-10-21
|w ger
915 _ _ |a JCR
|0 StatID:(DE-HGF)0100
|2 StatID
|b MAGN RESON MED : 2022
|d 2023-10-21
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0200
|2 StatID
|b SCOPUS
|d 2023-10-21
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0300
|2 StatID
|b Medline
|d 2023-10-21
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0199
|2 StatID
|b Clarivate Analytics Master Journal List
|d 2023-10-21
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)1050
|2 StatID
|b BIOSIS Previews
|d 2023-10-21
915 _ _ |a WoS
|0 StatID:(DE-HGF)0113
|2 StatID
|b Science Citation Index Expanded
|d 2023-10-21
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0150
|2 StatID
|b Web of Science Core Collection
|d 2023-10-21
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)1030
|2 StatID
|b Current Contents - Life Sciences
|d 2023-10-21
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)1190
|2 StatID
|b Biological Abstracts
|d 2023-10-21
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0160
|2 StatID
|b Essential Science Indicators
|d 2023-10-21
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)1110
|2 StatID
|b Current Contents - Clinical Medicine
|d 2023-10-21
915 _ _ |a IF < 5
|0 StatID:(DE-HGF)9900
|2 StatID
|d 2023-10-21
920 2 _ |0 I:(DE-He78)E020-20160331
|k E020
|l E020 Med. Physik in der Radiologie
|x 0
920 1 _ |0 I:(DE-He78)E020-20160331
|k E020
|l E020 Med. Physik in der Radiologie
|x 0
980 _ _ |a journal
980 _ _ |a VDB
980 _ _ |a I:(DE-He78)E020-20160331
980 _ _ |a UNRESTRICTED


LibraryCollectionCLSMajorCLSMinorLanguageAuthor
Marc 21