001     301567
005     20250829091435.0
024 7 _ |a 10.1002/mrm.30557
|2 doi
024 7 _ |a pmid:40411372
|2 pmid
024 7 _ |a 1522-2594
|2 ISSN
024 7 _ |a 0740-3194
|2 ISSN
024 7 _ |a altmetric:177441597
|2 altmetric
037 _ _ |a DKFZ-2025-01075
041 _ _ |a English
082 _ _ |a 610
100 1 _ |a Bulanov, Petr
|0 P:(DE-He78)d913cff5d92e46c7893927e308e71587
|b 0
|e First author
|u dkfz
245 _ _ |a Human liver CEST imaging at 7 T: Impact of B 1 + shimming.
260 _ _ |a New York, NY [u.a.]
|c 2025
|b Wiley-Liss
336 7 _ |a article
|2 DRIVER
336 7 _ |a Output Types/Journal article
|2 DataCite
336 7 _ |a Journal Article
|b journal
|m journal
|0 PUB:(DE-HGF)16
|s 1756451601_12783
|2 PUB:(DE-HGF)
336 7 _ |a ARTICLE
|2 BibTeX
336 7 _ |a JOURNAL_ARTICLE
|2 ORCID
336 7 _ |a Journal Article
|0 0
|2 EndNote
500 _ _ |a #EA:E020#LA:E020# / Volume 94, Issue 4 pp. 1604-1615
520 _ _ |a To explore the feasibility of CEST imaging in the human liver at 7 T with B 1 + $$ {B}_1^{+} $$ shimming.CEST MRI was performed on a 7 T whole-body scanner with a parallel transmission (pTx) system in five healthy volunteers. Static pTx ( B 1 + $$ {B}_1^{+} $$ shimming) was applied to locally maximize the B 1 + $$ {B}_1^{+} $$ magnitude per input power within a given region of interest (ROI) of approximately 30 mm diameter (ROIshim). Relaxation-compensated inverse magnetization transfer ratio (MTRRex) values were quantified for amide protons, guanidino protons, and relayed nuclear Overhauser effect signals based on five-pool Lorentzian fit analysis. MTRRex values were corrected for B1 inhomogeneities using an absolute, accurate MR fingerprinting-based B 1 + $$ {B}_1^{+} $$ mapping technique.Within the ROIshim, reliable MTRRex values could be calculated for an average of 85% of voxels. The mean MTRRex values and corresponding coefficient of variations across the group are: 0.113 ± 0.009, 8.8% for amide; 0.167 ± 0.010, 6.3% for nuclear Overhauser effect; and 0.079 ± 0.010, 12.9% for guanidino. MTRRex values exhibit low variation between subjects, as reflected by low coefficient of variations.In this study, we have demonstrated for the first time the feasibility of acquiring and quantifying relaxation-compensated CEST contrasts in the human liver at ultrahigh field. The application of static pTx effectively eliminates B 1 + $$ {B}_1^{+} $$ dropouts and allows for accurate CEST contrast quantification within the selected ROI. In addition, the proposed B 1 + $$ {B}_1^{+} $$ mapping technique shows efficacy for enhanced MTRRex B1 corrections in the abdomen.
536 _ _ |a 315 - Bildgebung und Radioonkologie (POF4-315)
|0 G:(DE-HGF)POF4-315
|c POF4-315
|f POF IV
|x 0
588 _ _ |a Dataset connected to CrossRef, PubMed, , Journals: inrepo02.dkfz.de
650 _ 7 |a 7 T
|2 Other
650 _ 7 |a B1 correction
|2 Other
650 _ 7 |a B1+ B 1 + $$ {B}_1^{+} $$ shimming
|2 Other
650 _ 7 |a body CEST
|2 Other
650 _ 7 |a liver CEST
|2 Other
650 _ 7 |a pTx
|2 Other
700 1 _ |a Menshchikov, Petr
|0 P:(DE-He78)877c77517aa07d7b3affbb072649e965
|b 1
|u dkfz
700 1 _ |a Grimm, Johannes
|0 P:(DE-He78)d40714cfcbbc151fe464dd2bd55952b8
|b 2
|u dkfz
700 1 _ |a Lutz, Max
|0 0009-0001-1956-3757
|b 3
700 1 _ |a Orzada, Stephan
|0 P:(DE-He78)7985b432d853ab8929db0f1cb121667f
|b 4
|u dkfz
700 1 _ |a Boyd, Philip
|0 P:(DE-He78)3c51ec0b06b6c9ccece5c7b5306de106
|b 5
|u dkfz
700 1 _ |a Bachert, Peter
|0 P:(DE-He78)29b2f01310f7022916255ddba2750f9b
|b 6
|u dkfz
700 1 _ |a Ladd, Mark
|0 P:(DE-He78)022611a2317e4de40fd912e0a72293a8
|b 7
|u dkfz
700 1 _ |a Korzowski, Andreas
|0 P:(DE-He78)577a5c61f44b8023e229610afbc7cd4e
|b 8
|u dkfz
700 1 _ |a Schmitter, Sebastian
|0 P:(DE-He78)19e2d877276b0e5eec11cdfc1789a55e
|b 9
|e Last author
|u dkfz
773 _ _ |a 10.1002/mrm.30557
|g p. mrm.30557
|0 PERI:(DE-600)1493786-4
|n 4
|p 1604-1615
|t Magnetic resonance in medicine
|v 94
|y 2025
|x 1522-2594
909 C O |p VDB
|o oai:inrepo02.dkfz.de:301567
910 1 _ |a Deutsches Krebsforschungszentrum
|0 I:(DE-588b)2036810-0
|k DKFZ
|b 0
|6 P:(DE-He78)d913cff5d92e46c7893927e308e71587
910 1 _ |a Deutsches Krebsforschungszentrum
|0 I:(DE-588b)2036810-0
|k DKFZ
|b 1
|6 P:(DE-He78)877c77517aa07d7b3affbb072649e965
910 1 _ |a Deutsches Krebsforschungszentrum
|0 I:(DE-588b)2036810-0
|k DKFZ
|b 2
|6 P:(DE-He78)d40714cfcbbc151fe464dd2bd55952b8
910 1 _ |a Deutsches Krebsforschungszentrum
|0 I:(DE-588b)2036810-0
|k DKFZ
|b 4
|6 P:(DE-He78)7985b432d853ab8929db0f1cb121667f
910 1 _ |a Deutsches Krebsforschungszentrum
|0 I:(DE-588b)2036810-0
|k DKFZ
|b 5
|6 P:(DE-He78)3c51ec0b06b6c9ccece5c7b5306de106
910 1 _ |a Deutsches Krebsforschungszentrum
|0 I:(DE-588b)2036810-0
|k DKFZ
|b 6
|6 P:(DE-He78)29b2f01310f7022916255ddba2750f9b
910 1 _ |a Deutsches Krebsforschungszentrum
|0 I:(DE-588b)2036810-0
|k DKFZ
|b 7
|6 P:(DE-He78)022611a2317e4de40fd912e0a72293a8
910 1 _ |a Deutsches Krebsforschungszentrum
|0 I:(DE-588b)2036810-0
|k DKFZ
|b 8
|6 P:(DE-He78)577a5c61f44b8023e229610afbc7cd4e
910 1 _ |a Deutsches Krebsforschungszentrum
|0 I:(DE-588b)2036810-0
|k DKFZ
|b 9
|6 P:(DE-He78)19e2d877276b0e5eec11cdfc1789a55e
913 1 _ |a DE-HGF
|b Gesundheit
|l Krebsforschung
|1 G:(DE-HGF)POF4-310
|0 G:(DE-HGF)POF4-315
|3 G:(DE-HGF)POF4
|2 G:(DE-HGF)POF4-300
|4 G:(DE-HGF)POF
|v Bildgebung und Radioonkologie
|x 0
914 1 _ |y 2025
915 _ _ |a Nationallizenz
|0 StatID:(DE-HGF)0420
|2 StatID
|d 2025-01-02
|w ger
915 _ _ |a DEAL Wiley
|0 StatID:(DE-HGF)3001
|2 StatID
|d 2025-01-02
|w ger
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0200
|2 StatID
|b SCOPUS
|d 2025-01-02
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0300
|2 StatID
|b Medline
|d 2025-01-02
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0199
|2 StatID
|b Clarivate Analytics Master Journal List
|d 2025-01-02
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)1050
|2 StatID
|b BIOSIS Previews
|d 2025-01-02
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0160
|2 StatID
|b Essential Science Indicators
|d 2025-01-02
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)1030
|2 StatID
|b Current Contents - Life Sciences
|d 2025-01-02
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)1190
|2 StatID
|b Biological Abstracts
|d 2025-01-02
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)1110
|2 StatID
|b Current Contents - Clinical Medicine
|d 2025-01-02
915 _ _ |a WoS
|0 StatID:(DE-HGF)0113
|2 StatID
|b Science Citation Index Expanded
|d 2025-01-02
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0150
|2 StatID
|b Web of Science Core Collection
|d 2025-01-02
920 2 _ |0 I:(DE-He78)E020-20160331
|k E020
|l E020 Med. Physik in der Radiologie
|x 0
920 1 _ |0 I:(DE-He78)E020-20160331
|k E020
|l E020 Med. Physik in der Radiologie
|x 0
920 0 _ |0 I:(DE-He78)E020-20160331
|k E020
|l E020 Med. Physik in der Radiologie
|x 0
980 _ _ |a journal
980 _ _ |a VDB
980 _ _ |a I:(DE-He78)E020-20160331
980 _ _ |a UNRESTRICTED


LibraryCollectionCLSMajorCLSMinorLanguageAuthor
Marc 21