Journal Article DKFZ-2025-01075

http://join2-wiki.gsi.de/foswiki/pub/Main/Artwork/join2_logo100x88.png
Human liver CEST imaging at 7 T: Impact of B 1 + shimming.

 ;  ;  ;  ;  ;  ;  ;  ;  ;

2025
Wiley-Liss New York, NY [u.a.]

Magnetic resonance in medicine 94(4), 1604-1615 () [10.1002/mrm.30557]
 GO

This record in other databases:  

Please use a persistent id in citations: doi:

Abstract: To explore the feasibility of CEST imaging in the human liver at 7 T with B 1 + $$ {B}_1^{+} $$ shimming.CEST MRI was performed on a 7 T whole-body scanner with a parallel transmission (pTx) system in five healthy volunteers. Static pTx ( B 1 + $$ {B}_1^{+} $$ shimming) was applied to locally maximize the B 1 + $$ {B}_1^{+} $$ magnitude per input power within a given region of interest (ROI) of approximately 30 mm diameter (ROIshim). Relaxation-compensated inverse magnetization transfer ratio (MTRRex) values were quantified for amide protons, guanidino protons, and relayed nuclear Overhauser effect signals based on five-pool Lorentzian fit analysis. MTRRex values were corrected for B1 inhomogeneities using an absolute, accurate MR fingerprinting-based B 1 + $$ {B}_1^{+} $$ mapping technique.Within the ROIshim, reliable MTRRex values could be calculated for an average of 85% of voxels. The mean MTRRex values and corresponding coefficient of variations across the group are: 0.113 ± 0.009, 8.8% for amide; 0.167 ± 0.010, 6.3% for nuclear Overhauser effect; and 0.079 ± 0.010, 12.9% for guanidino. MTRRex values exhibit low variation between subjects, as reflected by low coefficient of variations.In this study, we have demonstrated for the first time the feasibility of acquiring and quantifying relaxation-compensated CEST contrasts in the human liver at ultrahigh field. The application of static pTx effectively eliminates B 1 + $$ {B}_1^{+} $$ dropouts and allows for accurate CEST contrast quantification within the selected ROI. In addition, the proposed B 1 + $$ {B}_1^{+} $$ mapping technique shows efficacy for enhanced MTRRex B1 corrections in the abdomen.

Keyword(s): 7 T ; B1 correction ; B1+ B 1 + $$ {B}_1^{+} $$ shimming ; body CEST ; liver CEST ; pTx

Classification:

Note: #EA:E020#LA:E020# / Volume 94, Issue 4 pp. 1604-1615

Contributing Institute(s):
  1. E020 Med. Physik in der Radiologie (E020)
Research Program(s):
  1. 315 - Bildgebung und Radioonkologie (POF4-315) (POF4-315)

Appears in the scientific report 2025
Database coverage:
Medline ; BIOSIS Previews ; Biological Abstracts ; Clarivate Analytics Master Journal List ; Current Contents - Clinical Medicine ; Current Contents - Life Sciences ; DEAL Wiley ; Essential Science Indicators ; NationallizenzNationallizenz ; SCOPUS ; Science Citation Index Expanded ; Web of Science Core Collection
Click to display QR Code for this record

The record appears in these collections:
Document types > Articles > Journal Article
Institute Collections > E020
Public records
Publications database

 Record created 2025-05-26, last modified 2025-08-29



Rate this document:

Rate this document:
1
2
3
 
(Not yet reviewed)