Journal Article DKFZ-2026-00617

http://join2-wiki.gsi.de/foswiki/pub/Main/Artwork/join2_logo100x88.png
Improved Myocardial Sodium Quantification at 7 T Using Interleaved 23Na/1H pTx MRI With Motion and Anatomy-Based B1 Correction.

 ;  ;  ;  ;  ;  ;  ;  ;  ;  ;

2026
Wiley-Liss New York, NY [u.a.]

Magnetic resonance in medicine nn, nn () [10.1002/mrm.70342]
 GO

Abstract: To improve accuracy and repeatability of myocardial 23Na quantification in cardiac MRI at 7 T by combining retrospective respiratory and cardiac motion correction with a novel anatomy-based B1 bias field correction.In this study, a dual-nuclear interleaved 23Na/1H MRI sequence at 7 T was applied. Here, 1H MR data enabled automated segmentation of myocardium and blood pool via nnUNet and facilitated respiratory and cardiac motion correction for both contrasts using 1H navigators. For 23Na MRI, a novel anatomy-based B1 bias field correction was developed, estimating the transmit and receive (B1) field bias from 1H-derived segmentations and synthetic 23Na images. All correction methods were validated through realistic simulations and in vivo studies. Repeatability was assessed in 10 healthy subjects, and the proposed B1 correction was compared to phantom-based methods.Respiratory and cardiac motion correction reduced quantification errors and improved SNR compared to conventional gating. The anatomy-based B1 correction effectively mitigated errors caused by B1 inhomogeneities and outperformed phantom-based methods in terms of repeatability. The measured apparent tissue sodium concentration of the myocardium after all corrections (49.5 ± $$ \pm $$ 4.7 mM) was consistent with literature values. Combined motion and B1 corrections improved repeatability, reducing the coefficient of repeatability from 4.9 mM (11.2%) without corrections to 2.0 mM (4.0%) after corrections.The combination of retrospective motion correction and anatomy-based B1 bias field correction enables repeatable myocardial sodium quantification at 7 T. The interleaved acquisition facilitates robust segmentation and efficient use of 1H MRI for motion and B1 correction, providing a scalable framework for future clinical research studies.

Keyword(s): cardiac sodium (23Na) MRI ; interleaved dual‐nuclear MRI ; respiratory and cardiac motion correction ; transmit and receive (B1) correction ; ultrahigh field strength (7 T)

Classification:

Note: #LA:E020# / epub

Contributing Institute(s):
  1. E020 Med. Physik in der Radiologie (E020)
Research Program(s):
  1. 315 - Bildgebung und Radioonkologie (POF4-315) (POF4-315)

Appears in the scientific report 2026
Database coverage:
Medline ; BIOSIS Previews ; Biological Abstracts ; Clarivate Analytics Master Journal List ; Current Contents - Clinical Medicine ; Current Contents - Life Sciences ; DEAL Wiley ; Essential Science Indicators ; IF < 5 ; JCR ; NationallizenzNationallizenz ; SCOPUS ; Science Citation Index Expanded ; Web of Science Core Collection
Click to display QR Code for this record

The record appears in these collections:
Document types > Articles > Journal Article
Institute Collections > E020
Public records
Publications database

 Record created 2026-03-17, last modified 2026-03-17



Rate this document:

Rate this document:
1
2
3
 
(Not yet reviewed)