Journal Article DKFZ-2026-01038

http://join2-wiki.gsi.de/foswiki/pub/Main/Artwork/join2_logo100x88.png
Do AI-based contouring algorithms influence physicians in the online adaptive radiotherapy of patients with bladder cancer?

 ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;

2026
Elsevier [Erscheinungsort nicht ermittelbar]

Technical innovations & patient support in radiation oncology 38, 100401 () [10.1016/j.tipsro.2026.100401]
 GO

Abstract: In this prospective cross-over study, the precision of manual correction of the clinical target volume (CTV) during online-adaptive radiotherapy (ART) of patients with bladder cancer was investigated in dependence on the input of applied computational algorithms.Online-adaptive-radiation therapy (ART) fractions were analysed from a prospective registry as a component of a trimodality treatment for bladder cancer. The CBCT-guided adaptive radiation therapy (CBCTgART) workflow uses a CBCT acquired at the beginning of a treatment session (CBCT1) to update the target volume contours of the planning CT (pCT) on the current anatomy of the day. The study comprises radiotherapy fractions with target (CTV) segments showing clinically relevant deviations (>5 mm) when mapped between pre-treatment (CBCT1) and post-adaptation (CBCT2) images. CTValgo1-2 were obtained from two deformable-image-registration algorithms (algo1, algo2) based on AI-generated normal-tissue contours and a rigid copy of the CTVoriginal termed CTValgo3 (algo3). Verification cone-beam-computed-tomography (CBCT2) acquired during ART showed CTValgo1-3 on new anatomical scenarios. The task of 13 physicians was to adjust CTValgo1-3 on CBCT2 to match the CTVoriginal on CBCT1.In 151/169 pairwise comparisons, mean-distance-of-segments-to-ground-truth (MDAGT) after adjustment by a physician was larger for the poorer algorithms than for the better ones. The binomial proportion was 0.893, significantly different from 0.5 as null proportion (p < 0.0001, exact-binomial-test), and not dependent on the physician or on the respective patient. In a quantitative analysis by a mixed-model, the MDAGT of the manually adjusted segments between 16% and 50% of the errors were on average corrected by the physicians, with interindividual differences (p < 0.0001,F-test).The present study results reveal that the quality of AI-generated contours is of crucial importance for a proper online onboard ART, as errors may bias clinical workflow and contouring. The accuracy of supervised structures strongly depends on the accuracy of the AI generated contours before supervision.

Keyword(s): Artificial intelligence ; Human machine interaction


Note: #DKTKZFB9#

Contributing Institute(s):
  1. DKTK Koordinierungsstelle Essen/Düsseldorf (ED01)
Research Program(s):
  1. 899 - ohne Topic (POF4-899) (POF4-899)

Appears in the scientific report 2026
Database coverage:
Medline ; DOAJ ; Article Processing Charges ; Clarivate Analytics Master Journal List ; DOAJ Seal ; Emerging Sources Citation Index ; Fees ; SCOPUS ; Web of Science Core Collection
Click to display QR Code for this record

The record appears in these collections:
Document types > Articles > Journal Article
Public records
Publications database

 Record created 2026-05-04, last modified 2026-05-04


Rate this document:

Rate this document:
1
2
3
 
(Not yet reviewed)