Journal Article DKFZ-2023-02310

http://join2-wiki.gsi.de/foswiki/pub/Main/Artwork/join2_logo100x88.png
Simultaneous T1, T2 and T2⁎ mapping of the liver with multi-shot MI-SAGE.

 ;  ;  ;  ;  ;  ;  ;  ;

2024
Elsevier Science Amsterdam [u.a.]

Magnetic resonance imaging 105, 75-81 () [10.1016/j.mri.2023.11.004]
 GO

This record in other databases:

Please use a persistent id in citations: doi:

Abstract: To apply multi-shot high-resolution multi inversion spin and gradient echo (MI-SAGE) acquisition for simultaneous liver T1, T2 and T2* mapping.Inversion prepared spin- and gradient-echo EPI was developed with ascending slice order across measurements for efficient acquisition with T1, T2, and T2⁎ weighting. Multi-shot EPI was also implemented to minimize distortion and blurring while enabling high in-plane resolution. A dictionary-matching approach was used to fit the images to quantitative parameter maps, which were compared to T1 measured by modified Look-Locker (MOLLI), T1 measured by variable flip angle (VFA), T2 measured by multiple echo time-based Half Fourier Single-shot Turbo spin-Echo (HASTE), T2 measured by radial turbo-spin-echo (rTSE) and T2⁎ measured by multiple gradient echo (MGRE) sequences.The multi-shot variant of the sequence achieved higher in-plane resolution of 1.7 × 1.7 mm2 with good image quality in 28 s. Derived quantitative maps showed comparable values to conventional mapping methods. As measured in phantom and in vivo, MOLLI, MESE and MGRE give closest values to MISAGE. VFA, HASTE and rTSE show obvious overestimation.The proposed multi-shot inversion prepared spin- and gradient-echo EPI sequence allows for high-resolution quantitative T1, T2 and T2 liver tissue characterization in a single breath-hold scan.

Keyword(s): Liver ; Multi inversion spin and gradient echo ; Multi-shot acquisitions ; Parametric mapping

Classification:

Note: #LA:E010# / 2024 Nov 7:105:75-81

Contributing Institute(s):
  1. E020 Med. Physik in der Radiologie (E020)
  2. E010 Radiologie (E010)
Research Program(s):
  1. 315 - Bildgebung und Radioonkologie (POF4-315) (POF4-315)

Appears in the scientific report 2023
Database coverage:
Medline ; Clarivate Analytics Master Journal List ; Current Contents - Clinical Medicine ; Ebsco Academic Search ; Essential Science Indicators ; IF < 5 ; JCR ; NationallizenzNationallizenz ; SCOPUS ; Science Citation Index Expanded ; Web of Science Core Collection
Click to display QR Code for this record

The record appears in these collections:
Document types > Articles > Journal Article
Institute Collections > E010
Institute Collections > E020
Public records
Publications database

 Record created 2023-11-09, last modified 2024-02-29



Rate this document:

Rate this document:
1
2
3
 
(Not yet reviewed)