Journal Article DKFZ-2026-01396

http://join2-wiki.gsi.de/foswiki/pub/Main/Artwork/join2_logo100x88.png
A Sub-Microsecond Switch Enabling SWIFT 23Na Imaging at 10.5 T.

 ;  ;  ;  ;  ;  ;  ;  ;  ;  ;

2026
Wiley-Liss New York, NY [u.a.]

Magnetic resonance in medicine 96(4), 1991-2003 () [10.1002/mrm.70461]
 GO

Abstract: To enable sodium SWIFT imaging, which is a zero-echo time imaging technique, at ultra-high magnetic fields through the development of custom electronics hardware, and to showcase this capability with in vivo imaging results.The custom hardware developed consists of a high-speed optical trigger with 10 ns resolution, an in-bore PIN diode driver capable of sourcing high current, and RF switches (both an in-line switchable attenuator and transmit/receive switch) optimized to achieve sub-microsecond switching speeds while also producing isolation between the transmitter and receiver.Practical switching speeds of 0.6 μs (receive to transmit) and 1.7 μs (transmit to receive) are achieved on the RF switches, limited by transient-induced spurious emissions from the low noise amplifier. Transmit to receive isolation of 115 dB is achieved over a 1 MHz bandwidth, with 120 dB of isolation at the Larmor frequency. This was crucial to suppress unblanked RFPA noise. SWIFT images of the human wrist with 1.5 mm isotropic resolution were acquired in less than 5 min to demonstrate the utility of sodium SWIFT imaging at ultra-high field. SWIFT imaging signal-to-noise ratio in a reference phantom with heterogeneous sodium concentrations was comparable to ultra-short echo time imaging, which provided assurance that hardware had achieved the necessary specifications.The feasibility of sodium SWIFT imaging at ultra-high field was established, and a musculoskeletal imaging application was demonstrated. The success of this work enables further development of SWIFT at high and ultra-high fields for imaging of sodium, proton, and other nuclei.

Keyword(s): UHF ; X‐nuclei ; cartilage ; sodium MRI ; ultra‐high field MRI

Classification:

Note: Volume 96, Issue 4 pp. 1991-2003

Contributing Institute(s):
  1. Med. Physik in der Radiologie (E020)
Research Program(s):
  1. 315 - Bildgebung und Radioonkologie (POF4-315) (POF4-315)

Appears in the scientific report 2026
Database coverage:
Medline ; BIOSIS Previews ; Biological Abstracts ; Clarivate Analytics Master Journal List ; Current Contents - Clinical Medicine ; Current Contents - Life Sciences ; DEAL Wiley ; Essential Science Indicators ; IF < 5 ; JCR ; NationallizenzNationallizenz ; SCOPUS ; Science Citation Index Expanded ; Web of Science Core Collection
Click to display QR Code for this record

The record appears in these collections:
Document types > Articles > Journal Article
Institute Collections > E020
Public records
Publications database

 Record created 2026-06-09, last modified 2026-10-14



Rate this document:

Rate this document:
1
2
3
 
(Not yet reviewed)