Journal Article DKFZ-2024-02497

http://join2-wiki.gsi.de/foswiki/pub/Main/Artwork/join2_logo100x88.png
Relevance of Prostatic Fluid on the Apparent Diffusion Coefficient: An Inversion Recovery Diffusion-Weighted Imaging Investigation.

 ;  ;  ;  ;  ;  ;  ;  ;  ;  ;

2025
Ovid [Erscheinungsort nicht ermittelbar]

Investigative radiology 60(6), 357-368 () [10.1097/RLI.0000000000001139]
 GO

This record in other databases:

Please use a persistent id in citations: doi:

Abstract: Diffusion-weighted imaging (DWI) is pivotal for prostate magnetic resonance imaging. This is rooted in the generally reduced apparent diffusion coefficient (ADC) observed in prostate cancer in comparison to healthy prostate tissue. This difference originates from microstructural tissue composition changes, including a potentially decreased fluid-containing lumen volume. This study explored the nature of the observed ADC contrast in prostate tissue through inversion recovery-prepared DWI examinations that generated varying levels of fluid suppression.This institutional review board-approved, single-center, prospective study was conducted from 2023 to 2024; all participants underwent magnetic resonance imaging including DWI with b-values of 50 and 800 s/mm2 at 16 inversion times (TI; 60-4000 milliseconds). The measured ADC was interpreted with a 2-compartment model (compartments: tissue and fluid). Descriptive statistics were computed for all analyzed parameters.Twelve healthy male volunteers (45 ± 17 years) and 1 patient with prostate adenocarcinoma (66 years) were evaluated. The ADC map appearance depended heavily on the TI, and we observed a feature-rich ADC(TI) curve. The ADC in the transition zone (TZ) of healthy volunteers increased between TI = 60 milliseconds and approximately 1100 milliseconds, then dropped drastically before increasing again, stabilizing at a very high TI. This effect was greatly reduced in the patient's prostate cancer lesion. The 2-compartment model described this behavior well. After the inversion, tissue magnetization recovers faster, decreasing its signal contribution in absolute terms and resulting in an increase in the ADC. At the tipping point, the total magnetization is zero at b = 0, when the positive tissue magnetization and still-inverted fluid magnetization cancel out. A small diffusion encoding leads to a positive signal, thus generating an infinite ADC. After the tipping point, the fluid magnetization remains negative and thereby reduces the ADC.Prostate fluid appears to contribute significantly to prostate ADCs. Its contribution could be adjusted by choosing an appropriate inversion recovery preparation, potentially enhancing contrast for prostate cancer lesions.

Classification:

Note: 2025 Jun 1;60(6):357-368

Contributing Institute(s):
  1. E020 Med. Physik in der Radiologie (E020)
Research Program(s):
  1. 315 - Bildgebung und Radioonkologie (POF4-315) (POF4-315)

Appears in the scientific report 2024
Database coverage:
Medline ; Allianz-Lizenz ; BIOSIS Previews ; Biological Abstracts ; Clarivate Analytics Master Journal List ; Current Contents - Clinical Medicine ; Current Contents - Life Sciences ; Essential Science Indicators ; IF >= 5 ; JCR ; SCOPUS ; Science Citation Index Expanded ; Web of Science Core Collection
Click to display QR Code for this record

The record appears in these collections:
Document types > Articles > Journal Article
Institute Collections > E020
Public records
Publications database

 Record created 2024-12-03, last modified 2025-05-07



Rate this document:

Rate this document:
1
2
3
 
(Not yet reviewed)