Journal Article DKFZ-2025-00496

http://join2-wiki.gsi.de/foswiki/pub/Main/Artwork/join2_logo100x88.png
Assessing reliability and comparability of 4D flow CMR whole heart measurements using retrospective valve tracking: A single-vendor study in the Berlin research network.

 ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;

2025
Elsevier Science Amsterdam [u.a.]

Magnetic resonance imaging 119, 110368 () [10.1016/j.mri.2025.110368]
 GO

This record in other databases:

Please use a persistent id in citations: doi:

Abstract: This study investigated intracardiac flow dynamics and assessed the comparability and reliability of 4D flow CMR measurements across multiple sites within the Berlin Research Network for Cardiovascular Magnetic Resonance (BER-CMR) using 3D cine phase-contrast imaging with three-directional velocity encoding in a healthy traveling cohort.In a prospective multi-site cohort study, 20 healthy volunteers underwent CMR at different sites. Quantitative assessment of Forward flow Volume (FFV), Peak (PV) and Mean Velocity (MV) across the heart's valves were conducted using retrospective valve tracking. FFV of the aortic and pulmonary valves, measured via 4D flow CMR, was compared to each other and to Stroke Volume (SV) from cine imaging. Reliability was assessed using scan-rescan tolerance ranges from a single site, with equivalency assumed if other sites' confidence intervals fell within these ranges. Intra- and interobserver analyses evaluated measurement consistency.The final analysis included 19 healthy volunteers. Intersite comparability analysis across all four heart valves revealed a strong reliability for FFV, PV and MV, except for FFV at the mitral valve at two sites and PV at the tricuspid valve at one site. Correlation analysis of SV and FFV of the corresponding ventriculoarterial valves demonstrated good agreement (aortic valve: r = 0.89, P < 0.001; pulmonary valve: r = 0.88, p < 0.001). Inter- and intraobserver analyses yielded good to excellent agreement across all valves (ICC > 0.90, p < 0.001).4D flow CMR whole-heart measurements in healthy volunteers were consistent across sites, showing strong agreement despite physiological and technical variability. These findings support future multicenter studies.

Keyword(s): 4D flow CMR ; Cardiovascular magnetic resonance imaging ; Healthy volunteers ; Reliability

Classification:

Note: Volume 119, June 2025, 110368

Contributing Institute(s):
  1. E020 Med. Physik in der Radiologie (E020)
Research Program(s):
  1. 315 - Bildgebung und Radioonkologie (POF4-315) (POF4-315)

Appears in the scientific report 2025
Database coverage:
Medline ; Clarivate Analytics Master Journal List ; Current Contents - Clinical Medicine ; Ebsco Academic Search ; Essential Science Indicators ; IF < 5 ; JCR ; NationallizenzNationallizenz ; SCOPUS ; Science Citation Index Expanded ; Web of Science Core Collection
Click to display QR Code for this record

The record appears in these collections:
Document types > Articles > Journal Article
Institute Collections > E020
Public records
Publications database

 Record created 2025-03-07, last modified 2025-04-11



Rate this document:

Rate this document:
1
2
3
 
(Not yet reviewed)