Journal Article DKFZ-2026-00592

http://join2-wiki.gsi.de/foswiki/pub/Main/Artwork/join2_logo100x88.png
Radiation quality assessment in a clinical helium-ion beam using a SOI microdosimeter and a Timepix3 detector

 ;  ;  ;  ;  ;  ;

2026
Frontiers Media Lausanne

Frontiers in physics 14, 1698522 () [10.3389/fphy.2026.1698522]
 GO

Abstract: Accurate characterization of radiation quality is essential for assessing radiobiological effects in radiotherapy, yet remains a major challenge. As modern treatment strategies increasingly consider not only absorbed dose but also linear energy transfer (LET) as a radiation quality specifier, the need for reliable tools to measure radiation quality in clinical settings is growing. While physical dose is routinely measured during quality assurance procedures, the experimental assessment of radiation quality is still limited. Microdosimetry offers a promising approach to address this gap. In this study, radiation quality is assessed through a microdosimetric approach using two advanced active solid-state detectors with distinct geometries: a 3D-mushroom Silicon-On-Insulator (SOI) microdosimeter developed at the University of Wollongong and a hybrid silicon-pixel Timepix3 detector. Although both being silicon-based, their differing geometries, sensor thicknesses, and detection principles lead to notable variations in their energy deposition spectra. The response functions of the two detection systems exposed to an initially monoenergetic 149.02 MeV/u helium pristine peak are compared in terms of spectral distributions and their expectation values. Experimental data are complemented with Monte Carlo simulations performed using the FLUKA code to validate and interpret the measurements. The advantages and limitations of both detection systems are discussed in the context of efforts to standardize radiation quality measurements. Such standardization could facilitate the integration of LET-based dosimetry into treatment planning systems, thereby improving the precision of radiobiological damage assessments. Ultimately, accounting for detector-specific response differences is crucial for establishing protocols for experimental verification of radiation quality in radiotherapy, as no standard device or accredited experimental methodology has been unequivocally identified yet.

Classification:

Note: #EA:E210#LA:E210# / #DKTKZFB26# / #NCTZFB26#

Contributing Institute(s):
  1. E210 KKE Translationale Radioonkologie (E210)
  2. DKTK HD zentral (HD01)
  3. E040 Med. Physik in der Strahlentherapie (E040)
  4. Koordinierungsstelle NCT Heidelberg (HD02)
Research Program(s):
  1. 315 - Bildgebung und Radioonkologie (POF4-315) (POF4-315)

Appears in the scientific report 2026
Database coverage:
Medline ; Creative Commons Attribution CC BY (No Version) ; DOAJ ; OpenAccess ; Article Processing Charges ; Clarivate Analytics Master Journal List ; Current Contents - Physical, Chemical and Earth Sciences ; DOAJ Seal ; Essential Science Indicators ; Fees ; IF < 5 ; JCR ; SCOPUS ; Science Citation Index Expanded ; Web of Science Core Collection
Click to display QR Code for this record

The record appears in these collections:
Document types > Articles > Journal Article
Institute Collections > E040
Public records
Publications database
Open Access

 Record created 2026-03-13, last modified 2026-05-09


OpenAccess:
Download fulltext PDF Download fulltext PDF (PDFA)
Rate this document:

Rate this document:
1
2
3
 
(Not yet reviewed)