Journal Article DKFZ-2025-02664

http://join2-wiki.gsi.de/foswiki/pub/Main/Artwork/join2_logo100x88.png
Repeatability and reproducibility of maximum diameter measurements of prostate lesions on MRI with repositioning and variation of imaging sequences: A test-retest study.

 ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;

2026
Elsevier Science Amsterdam [u.a.]

Magnetic resonance imaging 127, 110578 () [10.1016/j.mri.2025.110578]
 GO

Abstract: To assess variability of maximum diameter measurements of prostate lesions in MRI assessing patient repositioning, rater and sequence effects.Forty-two patients were included retrospectively, who received a clinical bi-/multiparametric prostate MRI examination and agreed to have the T2-weighted (T2WI) and diffusion weighted-imaging (DWI) sequences scanned twice. Maximum diameter measurements of prostate lesions mentioned in the clinical radiologist reports were performed by four readers in multiple reading sessions for determination of inter-sequence (between two DWI sequences), inter-scan (between clinical and additional scan), intra-rater and inter-rater variability. The primary calculated metrics were the repeatability and reproducibility coefficient (RC/RDC), including pooled RC/RDC.Variability measured by RCs/RDCs was lowest for measurements obtained within the same reading session, with inter-scan RCs up to 5.6 mm/6.5 mm for T2WI/DWI, pooled RCs of 4.8 mm/5.8 mm, respectively, and inter-sequence RDCs of 5.4 mm-5.9 mm, pooled RDC 5.8 mm. Measurements performed in separate reading sessions demonstrated significantly higher variability for both settings in the majority of cases (RCs: up to 10.9 mm/11.7 mm/10.2 mm for T2WI/DWI/inter-sequence, p ≤ 0.002), pooled RCs/RDCs 9.2 mm-9.9 mm. Measurements necessarily generated in different reading sessions, i.e., intra-rater or inter-rater, demonstrated high variability (RCs/RDCs up to 11.4 mm/11.5 mm for T2WI/DWI).Prostate lesion measurements demonstrate considerable variability. When measured in one reading session by one rater, lesion diameter differences below the pooled RCs of 4.8 mm, 95 %-CI [3.9, 5.6] for T2WI and 5.8 mm, 95 %-CI [4.7, 7.1] for DWI should not necessarily assumed to be true biological change, as these differences may result from measurement- or repositioning-based variability alone. Caution needs to be taken assessing size changes.

Keyword(s): Dimensional measurement accuracy ; Magnetic resonance imaging ; Observer variation ; Prostate ; Reproducibility of results

Classification:

Note: #EA:E010#LA:E010# / Volume 127, April 2026, 110578

Contributing Institute(s):
  1. E010 Radiologie (E010)
  2. C060 Biostatistik (C060)
  3. NWG KKE Multiparametrische Methoden zur Früherkennung des Prostatakarzinoms (E250)
  4. DKTK HD zentral (HD01)
Research Program(s):
  1. 315 - Bildgebung und Radioonkologie (POF4-315) (POF4-315)

Appears in the scientific report 2025
Database coverage:
Medline ; Clarivate Analytics Master Journal List ; Current Contents - Clinical Medicine ; Ebsco Academic Search ; Essential Science Indicators ; IF < 5 ; JCR ; NationallizenzNationallizenz ; SCOPUS ; Science Citation Index Expanded ; Web of Science Core Collection
Click to display QR Code for this record

The record appears in these collections:
Document types > Articles > Journal Article
Institute Collections > E010
Public records
Publications database

 Record created 2025-12-01, last modified 2026-01-08



Rate this document:

Rate this document:
1
2
3
 